Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Path River Front |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Supply and filling of good earth ( suitable for turf) from approved source upto site of work including ramming dressing and watering in 15/22cm layers including spreading levelling and consolidation with power road roller of 8 to 10 tone capacity (to required gradient and camber with all leads and lifts carriages avg. lead of 20 Kms, head load T&P establishment charges as required etc complete |
| 5 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) complete |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 10 | Random Rubble masonry with hard stone (Quarry) in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) all complete. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | Flooring with cobcle stoneof approx. size 125x125x75mm thick laid on 25mm average thick cement motar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respects as per directions of EIC. |
| 13 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Rough chisel dressed all complete. |
| 14 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-inCharge. 30 mm thick |
| 15 | Seating Benches |
| 16 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) all complete. |
| 18 | Architechutural pointing on brick work incl. cutting grooves, with lime, surkhi and marble dust mortar in ration 1:1.5::1/2, 1 Lime : 1.5 Surkhi) Raised and cut pointing. |
| 19 | Carriage of Material Brcks for an avg. lead of 40 Kms |
| 20 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube all complete. |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class deodar wood. |
| 22 | Applying priming coat:With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works . |
| 23 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture all complete. |
| 24 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) all complete. |
| 25 | French spirit polishing, Two or more coats on new works including a coat of wood filler all complete. |
| 26 | Painting runway / taxi track/ apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge including cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats) |
| 27 | Carriage of Material:Sand for an avg. lead of 10 Kms |
| 28 | Stone Agg. for an avg. lead of 10 Kms |
| 29 | Stones for an avg. lead of 22 Kms |
| 30 | Devri Stone for an avg. lead of 40 Kms |
| 31 | Deck River Front |
| 32 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 33 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 35 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 36 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 37 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 38 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete. |
| 39 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 40 | Providing and fixing of decorative railing in deck as per specifications provided by consultant in Deodar wood incl. all leads, lifts, carriages as per directions of EIC etc complete. |
| 41 | Providing and fixing of decorative balusters in railing in deck as per specifications provided by consultant in Deodar wood incl. all leads, lifts, carriages as per directions of EIC etc complete. |
| 42 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 43 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 45 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 46 | Providing and fixing plain panelling with skirting chair rails, and cornice with necessary screws, priming coat on unexposed surface etc Second class Deodar Wood 40mm thick as per directions of EIC all complete. |
| 47 | French spirit polishing, Two or more coats on new works including a coat of wood filler all complete. |
| 48 | Carriage of Material: Stone Agg./Sand for an avg. lead of 10 Kms |
| 49 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level incl. headload- all complete. |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 51 | Providing and fixing Ist quality ceramic glazed wall tiles of approved make, in all colours, shades(of 7-8 mm thick of different sizes) as approved by Engineer- in-Charge, in walls, skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade incl. all carriages etc complete. |
| 52 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) all complete. |
| 53 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of ppropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqmu pto 5.00 sqm) |
| 54 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 55 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required colour coated Hi-Rib all carraige complete. |
| 56 | Providing and fixing of 10mm thick wooden knotted imported panelling fixed in soffits incl. underneath frame work of wooden jambs of size 50x25mm incl. wooden cornice of required size. The job shall also incl. scaffolding, finishing with coat of touch wood polishing etc all upto the satisfication of EIC complete. |
| 57 | Providing and fixing of plained eves boarding of 1st class kail wood 400x40mm nominal size all complete. |
| 58 | Providing and laying insulation with 32mm thick impervious, closed-cell cross-linked polyethylene (XLPE) foam insulation conforming to manufacturer's specification, minimum nominal density of 30 kg/cum=10% all complete. |
| 59 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 60 | 15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1 : 4 ( 1 cement : 4 fine sand) all complete. |
| 61 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 62 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent all complete. |
| 63 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 64 | Ruled/flush pointing on white sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio 1:1.5:1/2 one lime : 1.5 surkhi ( 50% red and 50% light yellow surkhi):1/2 marble dust ( the rate is inclusive of all materials and labours involved except scaffolding) |
| 65 | Varnishing with varnish of approved brand and manufacture: Two or more coats of glue sizing with copal varnish over and under coat of flatting varnish. |
| 66 | Providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building/ structure, upto 25 mtrs height above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 mtr.c/c, horizontal and vertical tubes joint with cup and lock system with M.s tube, M.S tubes Challis M.S clamps and stairs case system in the scaffolding for working platform etc. and maintaining it in a serviceable condition of execution of work of cleaning and/ or pointing and/or applying chemical and removing it their after the scaffolding system shall be stiffened with bracings, runners connecting with the building etc. where ever required. if feasible, for inspection of work at required location with essential safety features for the work men etc, complete as per directions and approval of Engineer-in-charge. Note: - 1) The elevational area of the scaffolding shall be measured for the payment purpose. 2) The payment will be made once only for execution all items of such works. |
| 67 | Carriage of Material:- Sand/Stone ag. Avg. lead of 10 Kms |
| 68 | Bricks for an avg. lead of 40 Kms |
| 69 | Sanitary Fittings for Cafe |
| 70 | providing fixing testing and commissioning of PVC pipe type B incl. cost of pipe , adhesive all carriages complete PVC Pipe 75mm dia |
| 71 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. External work including trenching, refilling etc. P PN-16 pipe , 25mm OD(SDR-7.4) |
| 72 | PN-16 pipe, 16mm OD(SDR-7.4) |
| 73 | Providing and fixing of 75mm size of PVC items of standard make Type-B ISI Marked incl. All fittings/fixtures etc complete. |
| 74 | Plain Bend |
| 75 | Collar |
| 76 | Door Bend |
| 77 | Plain Tee |
| 78 | P-Trap |
| 79 | PVC Cliff |
| 80 | Door Tee |
| 81 | Floor Trap |
| 82 | Cowel Cap |
| 83 | PVc Elbow |
| 84 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 85 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 86 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank . |
| 87 | Providing and fixing 15mm dia nominal bore plasticized PVC connection pipe with brass unions 45 cm length. |
| 88 | Providing and fixing of Cp Brass Angle Valve 15mm |
| 89 | Providing and fixing of soap cases of CP Brass of sandard quality all complete. |
| 90 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 91 | P/F of Stainless Steel Jali (Gratting) with or without hole for waste pipe for N-Trap weight not less than 70 gms. |
| 92 | Providing and fixing 50 liter capacity water heater Gyser of approved brand of Venus/ Recold/ Jaquar/ Hindware / cera or equivalent brand including its fixing at desired position complete in all respects as per directions of Incharge Engineer.. |
| 93 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420mm bowl depth 178mm all complete. |
| 94 | Electrification |
| 95 | LAMP POST Supply, installation and fixing of heritage architectural ornamental decorative cast iron pole having provision to fix decorative Light fixture. Installation of same with foundation bolts of suitable size to grout it into specially designed RCC foundation, as shown in the enclosed drawing. The decorative light fixture shall be fixed on the top of the pole. The details of pole & light are given below: -A. The Pole: The pole with light fixture shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing. The Cast Iron Pole of 2700 mm length. The pole has ornamental base (Approx.overall dimension-height 1175 mm, bottom dia 360mm) shall have a provision of inbuilt junction box for fixing MCB’s or cutouts with detachable window cover. The part above ornamental base design consists of decorative chinar leaves bamboo sections of circular shapes in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing as exsting. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)B. Light Fixture: The Cast Aluminium Light fittings best suitable for the Lamp Post shall be exactly similar as shown in the enclosed drawing same as existing, which is of nearly 360mm width, 820mm height. The fixtures have aluminium casted parts & spinning parts welded with decorative cast aluminium designs for better look. It shall have provision of led bulb of 30watt designed to illuminate large areas with its wide dispersion without affecting the environment. It shall have extra clear transparent acrylic sheet light cover with stainless-steel fastening elements. The fixture having provision to fix complete with required power supply. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%) C. Finish: Colour specification & finishing process must follow as per the ISI standard. All parts must be clean by SHOT blasting process. Further parts are painted in 4 layer coating(Coating thickness-125 to 150 micron) in which first layer with epoxy primer(to prevent corrosion),second layer with epoxy base colour,than third layer polyurethane (PU) metallic paint (Gold/Green/Copper/Silver) & final layer of polyurethane (PU) lacquer (to prevent ultra violets ray). |
| 96 | Providing and Laying RCC Foundation for 2.7 Mtr Poles as per drawing attached with Following Procedure & as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR .(Foundation work to be laid as per drawing)A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surfacecomplete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with MT bars Including straightening, cutting, bending, placing inposition and binding/welding together with bolts & Bars all complete.E) Centring and shuttering including strutting, propping etc. and removal of form work for Footing andF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEMG) Providing and Laying Reinforce cement Concrete of M-25 grade In Footing and Pedestal includingCuring the foundation for 7 days. |
| 97 | Supply and Installation of 2.7 Mtr lamp post (garden lighting pole of cast iron) as per the above mentioned specifications and as per enclosed drawing of Dwarka/Equivalent Make & Shall be approved by Department before Supplying,including cost of G.I wire for earthing.The item shall be inspected at source (manufacturing factory) by departmental employees before its dispatch or sample to be got inspected at source before manifacturing for which the contractor shall be liable to and fro charges by way of providing transport/ airfare, lodging and boarding for two employees. |
| 98 | Supply, installation, Testing and commissioning of decorative post top light fixture of Dwarka/Equivalent Make as per the specifications mentioned above and as per enclosed drawing including 30Watt LED inbuilt panel light of of Dwaraka/Equivalent Make. |
| 99 | Supply/Fixing/Testing and Commissioning of Cast iron/MS composite ornamental Bollard 900mm (as per Approved sample/Drawing enclosed) having provision at bottom for built in gear box fitted with PVC 4 way connector of suitable amp. The bollard shall be powder coated painted to be approved color from compitent authority,confirming as per enclosed drawing /image of Dwarka/Karara Mujasame/Equivalent Make & Shall be approved by Department before Supplying.(For Cafe Side) |
| 100 | Wiring in 1.5 Sq. mm 3-Core flexible, PVC insulated, round sheathed and annealed bare multi stranded copper conductor withstand voltage up to 1.1 KV of Polycab/Havells/RR-Kabel/Salzer/Finolex/Paraflex/Equivalent Make for service connection wires from bottom to top of the pole. (Complete in all respects). |
| 101 | Supply/Fixing/Testing and Commissioning of 6 Amp to 10 Amp Rating ,240v,*C* Curve 10K,SP Miniature Circuit Breaker suitable for inductive load and to be fitted in existing poles Complete with connections.(L&T/Siemens/ Legrand/ABB /Havells/BCH/Equivalent Make) |
| 102 | Supply/Fixing of 63 Amp of adquate size 4-Way in and 4-Way out Terminal Block/Connector Bottle/Pin type depending upon site conditions of standard make. |
| 103 | Supply/Fixing and Crimping of 16/25/35/50 Sq. mm aluminium lugs,cable thimbles at termination of the cables/ends including providing of insulation tapes. |
| 104 | Supply/Laying/Testing and Commissioning of following Al armored XLPE Insulated,PVC cable Havells/Polycab/RR-Kabel/KEI/Paramount/Equivalent Make. Including Supply/Laying of HDPE Pipe of required size, ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. |
| 105 | 4-Core 10 mm sq. |
| 106 | 4-Core 16 mm sq. |
| 107 | Design,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel. The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Multifunctional meter, R/Y/B Phase-indicators etc & angle iron stand painted in black colour of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects with following:-Incoming: 63 Amp-4 pole,25k-36kA MCCB with extended terminals Adjustable Thermal & Fixed Magnetic LK/ABB/Legrand/Simens Make =01 No & 100 Amp Suitable Al. Bus bar=01 SetOutgoing: 1) 32 Amp 4 pole TPN MCB of ABB/LK/Legrand/Schneider/Equivalent make as approved. =02 No.2) 163 Amp 4-Pole,415V Contactor = 01No. of ABB/LK/Legrand/Schneider/Equivalent make as approved. 3) Digital Astronimical Timer of GIC Make Specified as Below:* LCD Display with Green backlight* Precise time programming for Astro / Daily /Weekly / Pulse / Cyclic switching* Latitude / Longitude Database for 45 Countries and 280 cities* Settable Latitude / Longitude precise to the minute with time zone* Sunrise/Sunset or Twilight rise/set trigger modes * Ease of Day selection in Weekly programming* 50 ON/OFF programs, 10 Holiday Programs * Settable DST feature & Password protection* 16A Single and Dual relay outputs * Two Separate Relay outputs with independent Programming* 12/24 Hour Display Format * 6 Years Battery reserve * Simple Reset & Manual Override* Service/Load hours measurementPanel shall have provision for MCB’S/entry of cables from the bottom as required. |
| 108 | Part-B (Main Power Supply) |
| 109 | Supply/Laying/Testing and Commissioning of 3.5 Core 50 mm sq. Al armored XLPE Insulated,PVC cable Havells/RR-Kabel/KEI/Paramount/Equivalent Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01.5 Feet below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. The job further includes cost of Road cut and refilling of same with cement concrete where required.(From AVR Panel to Located Point) |
| 110 | Design,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel. The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Multifunctional meter, R/Y/B Phase-indicators etc & angle iron stand painted in black colour of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects with following:-Incoming: 100 Amp-4 pole,36kA MCCB with extended terminals Adjustable Thermal & Fixed Magnetic L&T/ABB/Legrand/Simens Make & 200 Amp Suitable Al. Bus barOutgoing: 200 Amp Suitable Al. Bus bar |
| 111 | Providing of Earthing Complete by GI Pipe 40mm 3 mtr long through GI Strip 25x3mm for existing/new Panels |
| 112 | Supply/Laying/Testing and Commissioning of 3.5-Core 35 mm sq. Al armored XLPE Insulated,PVC cable Havells/RR-Kabel/KEI/Paramount/Equivalent Make.Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. |
| 113 | CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming:100 Amp TPN MCCB 36kA with extended terminals Adjustable Thermal & Fixed Magnetic with ROH of Legrand/Siemens/ABB//LK make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set, Volt meter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1set(3) Bypass Switch:3-Phase, Four Pole 63-100 Amp,415V Ac,50Hz with ROH Bypass Switch Havells/Seimens/LK/ABB Make for bypassing 15 KVA AVR.(5) Outgoing:(1) 200 Amp TPN Bus bar Al Strips = 1(2) 63 Amps TPN MCB (16 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 02 No.(3) 63 Amps TPN MCCB (25-36 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 02 No.The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing. |
| 114 | Supply/Installation/Testing & Commissioning of 3-phase 15 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of Chinar/AE/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 120 Volts to 470 Volts and a balanced output Voltage of 420 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection. |
| 115 | P/F of sheet steel Kiosk/Canopy suitable to house 15KVA servo stabilizer of following capacities fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated. The Job includes angle iron servo stand of Suitable size of 2.5 Ft from Ground. |
| 116 | Part-C (Internal Electrification for Café/View Points) |
| 117 | Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Anchor/Salzer/Havells/Paraflex Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 118 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 119 | Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells/Paraflex Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 120 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 121 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells/Paraflex Make) |
| 122 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 123 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make) |
| 124 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 125 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer /Havells/Paraflex Make) & shall be approved before execution of work. |
| 126 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 127 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 128 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 129 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make |
| 130 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH/Equivalent Make) |
| 131 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH/Equivalent Make) |
| 132 | 25-32Amp. |
| 133 | 40Amp. |
| 134 | 63Amp. |
| 135 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 136 | 6 way , Double door |
| 137 | 8 way , Double door |
| 138 | Supplying and fixing following way, TPN, sheet steel, MCB distribution board, on surface/ recess, horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 139 | 6-Way (4+18) , Double door |
| 140 | 8-Way (4+24) , Double door |
| 141 | Supply/Installation/Testing and Commissioning of IP-65/68 Homogenous LED Strip (Warm Type) Warm light with following Specifications: Input Wattage: 08-10W / Mtr,Input Voltage: 220 - 240VAC,Input Frequency: 50 Hz, Input Current (Max): 50mA, Power Factor:. > 0.95,Surge Protection:2.5KV, High Voltage Protection:300V,HI-POT:1.5KV,IP Rating:IP 65/68,Working Temperature:-10°C to 50°C, LED:Bridgelux,Lumen Maintenance:70% After 50000 BH,Rated CCT: 3000K, 4000K, 6500K,Rated CRI:> 80,System Efficacy:100lm/W,Housing:Silicon Pipe covers the LED Strip Light of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 142 | Supply/Fixing/Testing and Commissioning of of Adoptor (CV DRIVER LED STRINGS 12 V 2 A IP44-66) of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 143 | Supply and fixing of 18 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 105 < 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2520 lumens with minimum system efficacy of 140 lumen/watt .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Wipro/Equivalent make. |
| 144 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft of 34-36 Watt(System lumen efficacy ≥120 <135 lm/Watt) of Powder coated Extruded aluminium/CRCA Body and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials.Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Trilux /Wipro/Equivalent make. |
| 145 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix/Equivalent Make. |
| 146 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Polycab/Orient Make.(5-Star) |
| 147 | Supplying, installation, Testing & Commissioning of 100 Watt (System lumen efficacy ≥120 and <135 lm/Watt) Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Surya/Wipro/Equivalent make. |
| 148 | Supply, Installation, Testing and Commissioning of LED RGB/ RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be completewith all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors & complete with driver as per requirement at site.(For Cafe/View Point) Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Surya/Wipro/Equivalent make. |
| 149 | 30 watt (length 300-1000 mm) |
| 150 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:160 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,200 Amp Bus bar Al Strips(3+1) = 1 Set, MultiFunctional Meter =1 No., phase indicators =1 set2. Generator Incomer:100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 10 KVA AVROutgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 04 No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 08 No for Sub main lighting/ACs(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 04 No for Sub main Lighting/InvertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. |
| 151 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:160 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,200 Amp Bus bar Al Strips(3+1) = 1 Set, MultiFunctional Meter =1 No., phase indicators =1 set2. Generator Incomer:100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 10 KVA AVROutgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 04 No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 08 No for Sub main lighting/ACs(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 04 No for Sub main Lighting/InvertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail