| 1 | SUB HEAD - I (Wiring Accesseries, MCB's, DB's) Supply, Fixing of following sizes of PVC conduits of ISI make along with the accessories in surface / recess inlcuding cutting the wall and making good the same is case of recessed condut\it as required. |
| 2 | 20mm dia |
| 3 | 30mm dia |
| 4 | Supply of following sizes of HDPE of ISI make along with the accessories in surface / recess inlcuding cutting the wall and making good the same is as required. |
| 5 | 25mm dia |
| 6 | Supply of following sizes of PVC casing and capping along with its necessery accessories such as iron Saddels, screws, PVC fasterners etc to complete as required to fix on the wall |
| 7 | 20 mm X 10 mm |
| 8 | 30 mmX10 mm |
| 9 | Supply of following sizes pvc insulated single core copper conductor cable of 90 mtr in a box for wiring in existing surface / recessed steel /PVC Conduit / PVC casing capping / wood batten alongwith other wires as required . |
| 10 | 1.5 Sq.mm PVC insulated Copper conductor cable. |
| 11 | 2.5 Sq.mm PVC insulated Copper conductor cable. |
| 12 | 4.0 Sq.mm PVC insulated Copper conductor cable. |
| 13 | 6.0 Sq.mm PVC insulated Copper conductor cable. |
| 14 | 10.0 Sq.mm PVC insulated Copper conductor cable. |
| 15 | 16.0 Sq.mm PVC insulated Copper conductor cable. |
| 16 | 4pair,0.5mm dia annealed copper conducter. |
| 17 | Coaxial TV cable RG-6,0.7mm solid copper conducter insulated PE insulated,sheilded with fine tinned copper braid protected with PVC sheath |
| 18 | UTP 4 Pair CAT6 LAN Cable |
| 19 | Supply of following sizes pvc insulated Armoured UTP CAT6 4 Pair LAN cablef for wiring in existing surface / recessed steel /PVC Conduit / PVC casing capping / wood batten alongwith other wires as required . |
| 20 | Armoured UTP CAT6 4 Pair LAN Cable |
| 21 | Supply of MCB's in the existing MCB DB's complete with connections, testing and commissioning etc.as required. (\\"C\\" Curve) |
| 22 | 6A,to 32 A,ratings MCB SP \\"C\\" Curve |
| 23 | 6A,to 32 A,ratingMCB Single Pole + Neutral \\"C\\" Curve |
| 24 | Supplying of following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 25 | 40 A (RCCB), having a sensitivity current upto 30 mA four pole, (three phase and neutral) |
| 26 | 63 A (RCCB), having a sensitivity current upto 30 mA four pole, (three phase and neutral) |
| 27 | Supply of MCB's in the existing MCB DB's complete with connections, testing and commissioning etc.as required. (\\"C\\" Curve) |
| 28 | UNO Mini Modular 32 Amp Double Pole C Curve MCB |
| 29 | Rewinding of following capacity Motor for pump including removal from the base and refixing back in the position, testing and commissioning etc and complete as required. |
| 30 | 7.5 HP |
| 31 | Overhauling of pump and motor for following capacities including replacement of bearing,water seal,rusted nuts & bolts,gland rope,repairing of shaft & impeller including rewiring complete in all respect & reinstallation of the same after completing the above job satisfactorily. |
| 32 | 7.5 HP |
| 33 | Disconnecting,removing and re installation of ceiling fan/exhaust fan/wall mount fan after |
| 34 | Rewinding of any type ceiling fan / Wall Fans |
| 35 | Repairing and Rewinding of exhaust fan upto 18\\" |
| 36 | Overhauling and replacement of both end bearing /bushiings of ceiling fan / exhaust fan/ pedestal / wall mount fan complete in all respect. |
| 37 | Repairing & Rewinding of Pedastal fan |
| 38 | Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. |
| 39 | 1200mm |
| 40 | 1400mm |
| 41 | Supply of fan hooks using anchor fasteners bolt nut with hook complete as required. |
| 42 | Supplying of following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 43 | 1 or 2 Module (75 mmX75 mm) |
| 44 | 3 Module (100 mmX75 mm) |
| 45 | 4 Module (125 mmX75 mm) |
| 46 | 6 Module (200 mmX75 mm) |
| 47 | 8 Module (125 mmX125 mm) |
| 48 | 12 Module (200 mmX150 mm) |
| 49 | TV Socket outlet modular type |
| 50 | Supplying of following Modular Concealed Plastic boxes etc. as required. |
| 51 | 1 or 2 Module |
| 52 | 3 Module |
| 53 | 4 Module |
| 54 | 6 Module |
| 55 | 12 Module |
| 56 | Supplying of following Surface Plastic boxes etc. as required. |
| 57 | Surface Box 10X12inch |
| 58 | MCB Box |
| 59 | SMC Junction Box of GSJB.2014 of outside dimension 230X170X105,Inside dimension 200X140X95 along with the Hinges along with the all required accessories. |
| 60 | Sub Head II (Supply and Fixing of material) Supply of following electrical materail,accessories & fittings, if necessary after removal of old one to store, complete in all respect and as per the instruction of the Scientist - in - charge at site. |
| 61 | Fluorescent tube light - 28 Watts T 5 Type |
| 62 | 36 W PL 4 pin |
| 63 | 18 W PL 2/4 pin |
| 64 | 11 W PL 2/4 pin |
| 65 | 8 / 9 W CFL ( Cool / Warm / Spiral) |
| 66 | 11W CFL( Cool / Warm / Spiral) |
| 67 | 20 / 18 W CFL ( Cool / Warm / Spiral) |
| 68 | Electronic Ballast for 1X28 W T5 - FTL with <10% THD |
| 69 | Electronic Ballast for 2X28 W T5 - FTL with <10% THD |
| 70 | Electronic Ballast for 2X36 W with <10% THD for PL 4pin X 2 |
| 71 | Tube light end holder |
| 72 | PL 2 Pin Holder |
| 73 | PL 4 Pin Holder |
| 74 | Brass Battten holder |
| 75 | Heavy duty Copper Ballast for PL- 1 X 9/11 W |
| 76 | Metal Halide lamp 400 Watt E40 (white) |
| 77 | Metal Halide lamp 400 Watt E40 (Yellow) |
| 78 | Electronic Ballast for Metal Halide lamp 400 E40 Watt |
| 79 | Metal Halide lamp holder E40 |
| 80 | Fluorescent tube light - 40 Watts |
| 81 | Heavy duty copper ballast for 1X36W / 40W FTL |
| 82 | 15 / 14 Watts LED bulbs |
| 83 | 9.0/10 Watt LED bulbs |
| 84 | Heavy duty Copper Ballast for PL- 1 X 18W |
| 85 | Fan Capacitor - 2.5 mfd / 250 V |
| 86 | Exhaust Fan Capacitor - 6 mfd/250V |
| 87 | Supply of following electrical materail,accessories & fittings, if necessary after removal of old one to store, complete in all respect and as per the instruction of the Scientist - in - charge at site. |
| 88 | Stepped type electronic fan regulator 1 modular |
| 89 | 5 amps 3 pin top |
| 90 | 15 amps 3 pin top |
| 91 | 4ft LED T5 tube light with fittings |
| 92 | Electronic choke for 1X18 W 2 Pin PL |
| 93 | Electronic choke for 1X18 W 4 Pin PL |
| 94 | Electricty meter |
| 95 | Door Bell |
| 96 | Brass 18 way neutral links with 30A capacity |
| 97 | LED 4 Pin PL 18W |
| 98 | PGSA2Z Control Panel 30a 4 Way Bakelite Connector Strip Double Row Barrier Black Terminal., Bakelite Electrical Wire Connector 4 Way Screw Terminal with required accessories. |
| 99 | Push Button with indicator Red UI:500V,Ith:10A/AC15:415:4A/DC13:110V,0.5A Red |
| 100 | Push Button with indicator Green UI:500V,Ith:10A/AC15:415:4A/DC13:110V,0.5A |
| 101 | Change Over Switch 6A,440V AC 50Hz |
| 102 | S P 5/6A one way modular Switch |
| 103 | S P 5/6 A two way modular Switch |
| 104 | S P 15/16A one way modular Switch |
| 105 | 6 Pin 15/16 A Modular Socket Outlet |
| 106 | Telephone Socket outlet (RJ 11) Modular Type |
| 107 | 3 Pin 5/6 A Modular Socket Outlet |
| 108 | MNX 18 Power Contactor of rating 18A,3Pole,240V AC,1NO |
| 109 | ADD on Block 2NO 2NC |
| 110 | MN2 Thermal Overaload realy of rating 9-15A,Direct mounting Auto/Manual Reset |
| 111 | MN2 Thermal Overaload realy of rating 14-23A, Direct mounting Auto/Manual Reset |
| 112 | MNX 9 Power Contactor of rating 9A,3Pole,240V AC,1NO |
| 113 | D2FR Earth Fault Realy |
| 114 | Stepped type Modular Fan Regulator (2module) |
| 115 | Altabright Night Glow 24W Tube Light | 22W + 2W Batten for Home Batten with Night Lamp (PBTM14227-PK2) |
| 116 | Supplying of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 117 | 18watt |
| 118 | 22watt |
| 119 | Supply of Panel Down light 2x2 ft. LED Panel light 2x2 ft. (System lumen efficacy ≥120 85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), 116 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025 SDCM(Standard Deviation Color Matching) CRCA Sheet Body (Thickness > 0.50 mm |
| 120 | 36 watt |
| 121 | Supplying of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 122 | 100watt |
| 123 | Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 124 | Operation and Maintenance of all Electrical Installations including IBMS, VRF & A/C System, Lift, Pump Houses, etc at CSIR-NIO, Regional Centre, Andheri (West), Mumbai & CTAF-Guest House, Mumbai including relevant conditions mentioned for the same to the followings. |
| 125 | During Office Working Hours (Monday to Saturday ). (One electrician will have to be available during office hour from 09.00 a.m. to 05.30 p.m.) |
| 126 | During Office Working Hours (Monday to Saturday ). (One helper will have to be available during office hour from 09.00 a.m. to 05.30 p.m.) |
| 127 | Execute the Preventive Shutdown maintenance of the Electrical System at CSIR-NIO, RC, Mumbai by providing necessery skilled and unskilled manpower, tools along with all necessary accessories such as greace, emery papers, petroleum jelly, etc., as required to complete the work in all respect and as per the instruction of the Scientist - in - charge at site. Please Enable Macros to View BoQ information |