| 1 | Excavation in foundations, trenches etc., in earth work, lift upto 1.50 mts. Stacking the excavated soil not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cms. Layers, when required into plinths sides of foundation etc., consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as directed within all leads & lifts as per entire satisfaction of Engineer in charge. |
| 2 | Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per the direction of Engineer-in-Charge. |
| 3 | Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including raking out joints in cement mortar 1 : 6 ( 1 cement : 6 sand) within all leads and lifts as per the direction of Engineer -in- Charge. |
| 4 | Brick work using common burnt clay building bricks of approved quality in super structure in cement mortar 1: 6 (1 cement : 6 sand) above plinth level up to floor two level (2nd class bricks) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 5 | Providing wood work in frames of doors, windows, clerestory, windows and other frames wrought, framed and fixed in position 2nd. Class deodar wood within all leads and lifts as per the direction of Engineer-in -Charge. |
| 6 | Providing and fixing paneled and glazed or paneled and glazed shutters for doors, windows and clerestory windows including bright finished / black enamelled iron butt hinges with necessary screws in 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. |
| 7 | Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for doors windows and clerestory windows including bright finished black enamelled iron hinges with necessary screws 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. |
| 8 | Providing form work with steel plates 3.15 millimetre thick welding with angle iron in frame 30x30x5 milimetre, so as to give fair finish including centering, shuttering strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 metres and removal of the same for in-situ-reinforced concrete and plain concrete work in:- |
| 9 | Foundations,footings,bases of columns etc. and mass concrete within all leads and lifts as per the direction of Engineer-in- Charge. |
| 10 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc. up to 200 milimetres in thickness within all leads and lifts as per the direction of Engineer -in- Charge. |
| 11 | Beams, cantilever, girders and lintels sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding one metre in depth in all heights from floor within all leads and lifts as per the direction of Engineer -in- Charges. |
| 12 | Providing and laying cement concrete work 1 : 2 :4 ( 1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work |
| 13 | Foundations, footings bases of columns and the like mass concrete within all leads and lifts as per direction of Engineer-in-Charge. |
| 14 | In suspended floor roofs, landing & shelves and their support balconies, beams, girders, bressumers and cantilever upto floor two level within all leads and lifts as per the direction of Engineer-in-Charge. |
| 15 | Providing and laying cement concrete work 1 : 1. 50 : 3 ( 1 cement : 1.50 sand: 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:- |
| 16 | Lintels beams, girders, brassumers and cantilevers upto two level within all leads and lifts as per direction of Engineer-in-Charges. |
| 17 | Cement concrete flooring 1 : 2 :4 ( One cement : two sand : four graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement ( 40mm thick.) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 18 | 20mm cement plaster in single on rough side of brick / concrete /stone masonry wall for interior plastering up to floor two level including arises, internal rounded angles chamfers and or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1 : 6 ( 1cement : 6 sand ) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 19 | 6mm cement plaster to ceiling in cement mortar 1 : 3 ( 1cement : 3 sand) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 20 | Providing plinth protection 50mm thick in cement concrete 1 : 3 : 6 ( 1 cement:3 sand : 6 graded stone aggregate 20 mm. nominal size ) and including finishing the top surface of concrete smooth within all leads and lifts as per the direction of Engineer-in -Charge. |
| 21 | Providing tor steel reinforcement for reinforced concrete work including bending, binding, & placing in position complete upto floor two level) within all leads and lifts as per direction of Engineer-in-charge. |
| 22 | Applying two coats of wood preservative on new wood and wood preservative on new wood and wood preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter,sand papering and knotting. |
| 23 | Applying priming coat over new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter sand papering and knotting with ready mixed paint brushing wood primer for enamel within all leads and lifts as per the direction of Engineer-in -Charge. |
| 24 | Painting two coats( excluding priming coat) over new wood and wood based surfaces with enamel paint (other than white) brushing to give an even shade including clearing the surface of all dirt,dust and foreign matter, sand papering and stopping within all leads and lifts as per the direction of Engineer-in -Charge. |
| 25 | White washing with lime on undecorated wall surface ( two coat ) to give an even shade including thoroughly booming the surface to remove all dirt, dust and other foreign matter within all leads and lifts as per the direction of Engineer-in -Charge. |
| 26 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface(two coat ) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials within all leads and lifts as per the direction of Engineer -in- Charges. |
| 27 | Providing and fixing M.S. fan clamp Type-1 of 16mm dia M.S. bar bent to shape with hooked ends in RCC slab during laying including painting the exposed portion of loop, all as per standard design complete within all leads and lifts as per the direction of Engineer-in -Charge. |
| 28 | Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm diameter bolts & nuts and wooden plugs and embedding in cement concrete block 30x10x15cm. 1:3:6 ( 1 cement : 3 sand: 6 graded stone aggregate 20mm nominal size) within all leads and lifts as per the direction of Engineer -in- Charges. |
| 29 | Providing and fixing M.S. sliding door bolts bright finished or / and black enamelled with bolts and nuts screws etc. (250x16mm) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 30 | Providing and fixing M.S. Tower bolts ( barrel type ) with necessary screws (200x10mm) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 31 | Providing and fixing M.S. Tower bolts ( barrel type ) with necessary screws (150x10mm) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 32 | Providing and fixing M.S. Tower bolts ( barrel type ) with necessary screws (100x10mm) within all leads and lifts as per the direction of Engineer-in -Charge. |
| 33 | Providing and fixing M.S. handles with necessary screws complete 100mm within all leads and lifts as per the direction of Engineer-in -Charge. |
| 34 | Providing and fixing M.S. handles with necessary screws complete 75mm within all leads and lifts as per the direction of Engineer-in -Charge. |
| 35 | Providing and fixing M.S. round bars (16mm) grills of required pattern in wooden frames of windows etc. with M.S. Flats square or round bars with round headed bolts and nuts or by screws plain grill within all leads and lifts as per the direction of Engineer-in -Charge. |
| 36 | Stone / boulder filling under floor within all leads and lifts as per the direction of Engineer-in -Charge. Please Enable Macros to View BoQ information |