| 1 | Part-A, Erection of By |
| 2 | Carriage of Following structure on vehicle from EFU Naini to 132 KV S/S PDDU Nagar chunar distance approx. 130 km, 1. 33 kV ABL (02 Set) 2. 33 kV ALP (09 Set) |
| 3 | Sorting, Counting, Stacking erection mark wise and proper loading of structure on vehicle. |
| 4 | safe carriage of structure from EFU Naini to 132 KV S/S PDDU Nagar through vehicle to be provided by the contractor |
| 5 | Unloading of structure from vehicle, its sorting counting and proper staking at the premises of 132 KV S/S PDDU Nagar at suitable place. |
| 6 | Erection of Main and Auxiliary structure by shifting of structure from store to work site as per relevant drawing and practices using Nut-Bolt and spring washers.The structure material shall be supplied by department free of cost but the contractor has to manage T&P and all other associated work to complete the job satisfactory |
| 7 | Erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material from store to work site and including all other associated work to complete the job satisfactory |
| 8 | 36KV CT/PT |
| 9 | 36KV VCB |
| 10 | 36KV BSI |
| 11 | 36KV LSI |
| 12 | Junction box for 36KV CT |
| 13 | Junction box for 36KV PT |
| 14 | C&R Tripple Feeder Panel |
| 15 | Jumpering of equipments using single/double panther/moose conductor from bus bar to isolators, CB,CT etc. |
| 16 | Laying of following size control cable in the cable trench from control relay Drive Mechanism as per cable schedule its saddling at every 75mm distance with MS saddles of size of size 25x3mm , including carriage of cable drums from store to Laying site and all other associated work to complete the job satisfactory |
| 17 | 2Cx2.5 sq.mm |
| 18 | 4Cx2.5 sq.mm |
| 19 | 6Cx2.5 sq.mm |
| 20 | Termination of above cable as per schedule including making necessary holes in gland plates of approximate size and to provide ferrules and nos for each core of cable and its termination with all other associated works to complete the Job. |
| 21 | 2Cx2.5 sq.mm |
| 22 | 4Cx2.5 sq.mm |
| 23 | 6Cx2.5 sq.mm |
| 24 | Earthing of Main and Auxiliary structure & various type equipments CT, PT,CB,LA,LSI,BSI etc, by MS strip including welding with main earthmat below 700-800 mm below the ground level and above ground up to top of structure/ equipments including excavation of earth, welding with main earthmat and painting of earthing plate with green colour of standard quality paint including cost of all consumable material including MS Flat etc, labour and T & P Should be provided by contractor |
| 25 | Supply and Laying of 30/32/50 mm dia GI Pipe B Class Medium for conducting of control cable (metering) complete with elbow, tee, socket, reducer as per site requirement in the swithch yard |
| 26 | Providing and fixing of 33 bay equipment name plate of 2mm thick aluminium sheet plate size 600x300 mm with covering retro refelecting sheet base yellow colour & letter in blue colour |
| 27 | Generation energy saving and environment friendly long life versetile pressure die - cast aluminium outdoor high beam flood light with power 150 watt (LED light Philllips/ Havells/CGL/Surya Make) as light source and exclusively designed carbonate fitting. |
| 28 | Fixing & Installation of : Reflective Sign Board of size 8 ft x 6 ft for Sub Station Single Line Diagram to be fixed in Control Room Building of the Sub Station.The Board shall be made of made of 4 mm thick Aluminium Sheet covered with 3 M HIP Retro Reflective Sheet of required size with Single Line Diagram of 220/132/33 KV S/S by using 3 M HIP Retro Reflective Sheet as per prescribed color scheme and shall be provided with back support frame & fixing arrangement as per requirement/instructed by supervising engineer |
| 29 | Part-B, Supply for Erection of Bay |
| 30 | 33 KV Isolator clamp suitable for ACSR twin panther conductor with N&B |
| 31 | CT Clamp twin panther 18 mm rod size with N&B |
| 32 | PG Clamp Suitable for Panther to Panther with N&B |
| 33 | PG Clamp Suitable for Moose to Panther with N&B |
| 34 | Nut Bolt with washers 16*40mm |
| 35 | Nut Bolt with washers 16*45mm |
| 36 | Nut Bolt with washers 16*50mm |
| 37 | 10kV Digital Insulation Tester of Standard make (Megger) |
| 38 | 23W LED Tubelight Fitting Phillips/Havells/CGL Make |
| 39 | 16A MCB 10kA, 230V Havells/Siemese/Anchor Make |
| 40 | 6A MCB 10kA, 230V Havells/Siemese/Anchor Make |
| 41 | Outdoor ACDB 16 way TPN 415 V, Havells/Anchor/Std Make |
| 42 | Portable earthing/Discharge Rod (in Canvas Bag) of ''F'' Class Fiber Insulation suitable for working on Transmission Network Having System Voltage up to 145 K.V. (length of 10m) |
| 43 | Digital Multimeter (4 1/2 digit) (Motwane/Std Make) |
| 44 | Digital Clamp Meter of (Motwane/Std Make) with 0mA-300A |
| 45 | Voltmeter 0-3V Std Make |
| 46 | Self Supported Alluminium Ladder |
| 47 | 36kV CT Junction Box |
| 48 | 36kV PT Junction Box Please Enable Macros to View BoQ information |