Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Submission of design, drawing, testing of bearing capacity of soil and supply of all material, labour T&P etc. and construct as per tenderer's own seismic proof design and drawings (approved by the department) complete intze Type on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank of following capacity and staging from made up ground level at site to the top of bottom ring beam of tank, with a minimum free board of 15cm. The design of the tank shall base on safe bearing capacity of soil at site as 8 T/m2 and depth of foundation as 2.50m from existing ground level on pile/raft foundation. made up level of OHT will be taken as 0.70 m above existing gound level. Extra earth required for made up level will be arranged by the contractor at his own cost. If the bearing capacity of soil less than 8 T/m2than the contractor will submit the design on the same B.C. No extra payment will be paid for this. All other details of tank not covered here shall also be as per specifications enclosed. |
| 2 | 500 Kl/ 20 m staging (Zone-5A) |
| 3 | 1700 Kl/ 22 m staging (Zone-7A) |
| 4 | 500 Kl/ 22 m staging (Zone-7B) |
| 5 | 400 Kl/ 22 m staging (Zone-7C) |
| 6 | Submission of detailed design and drawing from any recognized University such as I.I.T. etc. or as per direction of Engineer in-charge. |
| 7 | R.C.C. as per approved design including fixing variours pipes and ventilator at top and fixing of M.S. sheet of 10 mm gauge manhole cover of 60cm x 60cm size with frame and locking arrangement and railing including supply of all material. |
| 8 | Two coloumn R.C.C. stair case with 1.0 m minimum clear width attached with tank body as an access to Balcony and Top Dome of tank from ground level as per design & drawing with 1.25 m high railling and ss gate with cabin as per specification including supply of all materials. |
| 9 | Supply and fixing of S.S.. ladder from inside the tank body from roof to the bottom dome of the tank in a slope of 3 : 1 (3 vertical : 1 horizontal) with raling as specified. |
| 10 | Railing on staircase & its landings, all around balcony & top dome for access up to ventilator as specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe.icluding ss casing aproved by E/C |
| 11 | Supply and fixing of digital water level indicator as per specifications and fixing of lightening conductor and earth plate etc. as per specifications. |
| 12 | Testing of tank for water tightness as per specifications enclosed including supply of water. |
| 13 | Supply of all materials and construction of 25mm thick P.C.C. floor over 80 mm PCC 1:4:8 in apron and 15 cm dia semi circular drain around apron in a slope towards wash out chamber. |
| 14 | Three coats of approved quality and shade of Apex Painting of as per direction of Engineer incharge over concrete work including supply of all materials etc. |
| 15 | Supplying, carting and fixing of following sizes C.I. D/F pipes with required specials such as reducers, duck foot bend, bell mouth etc. in inlet the tank including supply of M.S. clamps, rubber insertion sheet, nut bolts, washer etc. complete as per specifications : For Zone - 5A a. 150 mm dia in inlet-2 Nosb. 250 mm dia in outlet-1No.c. 250mm dia in over flow-1Nod. 100 mm dia in wash out-1No. |
| 16 | Supplying, carting and fixing of following sizes C.I. D/F pipes with required specials such as reducers, duck foot bend, bell mouth etc. in inlet the tank including supply of M.S. clamps, rubber insertion sheet, nut bolts, washer etc. complete as per specifications : For Zone - 7A a. 200 mm dia in inlet-2 Nosb. 400 mm dia in outlet-1No.c. 350mm dia in over flow-1Nod. 150 mm dia in wash out-1No. |
| 17 | Supplying, carting and fixing of following sizes C.I. D/F pipes with required specials such as reducers, duck foot bend, bell mouth etc. in inlet the tank including supply of M.S. clamps, rubber insertion sheet, nut bolts, washer etc. complete as per specifications : For Zone - 7B a. 200 mm dia in inlet-1 Nosb. 250 mm dia in outlet-1No.c. 250mm dia in over flow-1Nod. 100 mm dia in wash out-1No. |
| 18 | Supplying, carting and fixing of following sizes C.I. D/F pipes with required specials such as reducers, duck foot bend, bell mouth etc. in inlet the tank including supply of M.S. clamps, rubber insertion sheet, nut bolts, washer etc. complete as per specifications : For Zone - 7C a. 200 mm dia in inlet-1 Nosb. 250 mm dia in outlet-1No.c. 250mm dia in over flow-1Nod. 100 mm dia in wash out-1No. |
| 19 | Suplly all materials labour T&P and construct brick masonry sluice valve chambers including R.C.C. cover as per deptt. Type design at inlet, outlet and washout pipes. The R.C.C. cover shall be casted in S.S. Channel section with handles on both sides. (Sluice valve chamber for over flow & wash out may be combined) |
| 20 | The words U.P. Jal Nigam (urban), stating year of construction, capacity of O.H.T. and slogan approved by Engineer in charge shall be painted prominently in letter not less than 30 cm. in height. |
| 21 | Maintenance for 12 months inclucding supply of all materials etc. complete. |
| 22 | RISING MAIN |
| 23 | Dismantling of following type of road surface for laying of pipe line including sorting out of serviceable and unserviceable materials proper stacking of serviceable materials at suitable place and disposal of unserviceable materials at suitable place. |
| 24 | Bituminous Road |
| 25 | Cement Concrete Road |
| 26 | Interlocking C.C. Tile Road |
| 27 | Excavation of earth in ordinary soil (loam, clay or sand) to give upto 1 mt. Cover from top of the pipe including lift upto 1.5mt. and lead from centre of trenches and refilling of earth in 20 cm. layers with watering and ramming etc. complete in all respect. |
| 28 | Supply of following pipes including cost of pipes, FOR destination, all taxes duties and insurance charges, cost of jointing materials, loading unloading, third party inspection charges, packing and forwarding charges, road transportation charges etc complete. |
| 29 | 150 mm dia D.I. K-9 Pipe (conforming to IS : 8329)or latest amenment |
| 30 | 200 mm dia D.I. K-9 Pipe (conforming to IS : 8329)or latest amenment |
| 31 | Carting, laying & jointing following type of pipes and lowering the same into already prepared trenches and laying true to alignment and gradient, including all labour, T&P, supply & fixing of all D.I./ CI specials conforming to latest / relevant IS specification as per requirement of site, loading and unloading, shifting of public utilities if any, also includes sectional pressure testing of pipe line etc. all complete as per direction of Engineer in charge. |
| 32 | 150 mm dia D.I. K-9 Pipe |
| 33 | 200 mm dia D.I. K-9 Pipe |
| 34 | Supply, Carting to site of work, lowering, fixing and jointing of following sizes of fittings in trenches including FOR destinstion, all taxes and insurance, cost of fittings, all jointing materials, such as rubber packing, nut bolts any type of D.I. specials etc. complete work as per direction of Engineer in charge. |
| 35 | 150 mm C.I. D/F Sluice Valve IS 780-1969 |
| 36 | 200 mm C.I. D/F Sluice Valve IS 780-1969 |
| 37 | CI double orifice type Air valve 20 mm dia |
| 38 | RCC thrust block in RCC 3:1.5:1 (3 parts stone grit 10 to 20 mm, 1.5 parts coarse sand and 1 part of cement) including cost of material, all labour T&P etc. complete work. |
| 39 | MS steel of iron work in plain work such as R.C.C. work (when not included in overall rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage. |
| 40 | Supply of all materials and construction of following chambers as per type design of U.P. Jal Nigam including supply of labour, materials, T&P etc. complete. |
| 41 | Sluice Valve Chambers (Masonry Type) |
| 42 | Air Valve Chambers |
| 43 | Reinstatement of following type of roads including supply of all materials, labour, T&P etc.required for proper compiition of work as per specifications |
| 44 | Bituminous Road which includes Laying of Bituminous road providing grannular sub base, WBM, Dense bituminous macadam and bituminous concrete course in desired thickness along with primer, tack coat and seal coat (Thick ness may be taken according to PWD specification of the respective roads) and proper compaction including all material, labour, T&P etc. complete. |
| 45 | Cement Concrete Road which includes Laying C C road slab 100mm thick in 1:2:4 cement, coarse sand and 20 mm stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge. |
| 46 | P.C.C. (1:4:8) in base concrete 75 mm thick in cement, course sand and 40 mm th. Stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge. |
| 47 | C.C.Tiles Road which includes Laying of 80mm thick C.C soling including dressing surface and including supply of tile, filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work with P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast. |
| 48 | DISTRIBUTION SYSTEM |
| 49 | Dismantling of following type of road surface for laying of pipe line including sorting out of serviceable and unserviceable materials proper stacking of serviceable materials at suitable place and disposal of unserviceable materials at suitable place. |
| 50 | Bituminous Road |
| 51 | Cement Concrete Road |
| 52 | Interlocking C.C. Tile Road |
| 53 | Excavation of earth in ordinary soil (loam, clay or sand) to give 1 mt. Cover from top of the pipe including lift upto 1.5 mt. and lead from centre of trenches and refilling of earth in 20 cm. layers with watering and raimming etc. complete in all respect. |
| 54 | Supply of following pipes including cost of pipes, FOR destination, all taxes duties and insurance charges, cost of jointing materials, loading unloading, third party inspection charges, packing and forwarding charges, road transportation charges etc complete. |
| 55 | D.I. Pipe K-7 conforming to IS 8329 / 2000 or its latest amendment |
| 56 | 200 mm dia |
| 57 | 250 mm dia |
| 58 | 300 mm dia |
| 59 | 350 mm dia |
| 60 | 400 mm dia |
| 61 | HDPE Pipe PN 6 : class PE 100 as per B.I.S. code no. 4984 / 2016 or its latest amendment |
| 62 | 110 mm dia |
| 63 | 125 mm dia |
| 64 | 140 mm dia |
| 65 | 160 mm dia |
| 66 | 180 mm dia |
| 67 | Carting, laying & jointing following type of pipes and lowering the same into already prepared trenches and laying true to alignment and gradient, including all labour, T&P, supply & fixing of all HDPE / D.I./ CI specials conforming to latest / relevant IS specification as per requirement of site, loading and unloading, shifting of public utilities if any, also includes sectional pressure testing of pipe line etc. all complete as per direction of Engineer in charge. |
| 68 | D.I. Pipe K-7 conforming to IS 8329 / 2000 or its latest amendment |
| 69 | 200 mm dia |
| 70 | 250 mm dia |
| 71 | 300 mm dia |
| 72 | 350 mm dia |
| 73 | 400 mm dia |
| 74 | HDPE Pipe PN 6 : class PE 100 as per B.I.S. code no. 4984 / 2016 or its latest amendment |
| 75 | 110 mm dia |
| 76 | 125 mm dia |
| 77 | 140 mm dia |
| 78 | 160 mm dia |
| 79 | 180 mm dia |
| 80 | Supply, Carting to site of work, lowering, fixing and jointing of following sizes of fittings in trenches including FOR destinstion, all taxes and insurance, cost of fittings, all jointing materials, such as rubber packing, nut bolts any type of HDPE/D.I. specials etc. complete work as per direction of Engineer in charge. |
| 81 | C.I. D/F Sluice Valve (PN 1.0/ IS 14846) |
| 82 | 200mm Dia |
| 83 | 150mm Dia |
| 84 | 125mm Dia |
| 85 | 100mm Dia |
| 86 | Scour Valve (PN 1.0/ IS 14846) |
| 87 | 100mm Dia |
| 88 | 125mm Dia |
| 89 | Fire Hydrant ( as per latest IS specifications) |
| 90 | 80 mm dia (Sluice Valve Type) |
| 91 | Air Valve Single Orifice ( as per latest IS specifications) |
| 92 | 20 mm dia |
| 93 | Supply of all materials and construction of following chambers as per type design of U.P. Jal Nigam including supply of all labour, material, T&P etc. complete. |
| 94 | Sluice Valve Chambers (Surface Box Type) |
| 95 | Fire Hydrant Chambers |
| 96 | Air Valve Chambers |
| 97 | Supply of all labour, materials, T&P etc. all complete and inter - connecting existing system with the proposed distribution network at various points. Diameter from 90 mm to 350mm pipeincluding all labour T&P etc. required for proper completion of work |
| 98 | Supply of all labour, materials, T&P etc. all complete and disconnecting existing system to segregate zonal distribution network at various points. including all labour T&P etc. required for proper completion of work |
| 99 | Crossing of Nala small (up to 1.0 m wide) and culvert by making hole below its bed without obstructing the flow of water and also including the repair of any damages done during this work including suppyling and laying of C.I. Pipe etc. complete as per direction of engineer in charge. |
| 100 | Reinstatement of following type of roads including supply of all materials, labour, T&P etc.required for proper compiition of work as per specifications |
| 101 | Bituminous Road which includes Laying of Bituminous road providing grannular sub base, WBM, Dense bituminous macadam and bituminous concrete course in desired thickness along with primer, tack coat and seal coat (Thick ness may be taken according to PWD specification of the respective roads) and proper compaction including all material, labour, T&P etc. complete. |
| 102 | Cement Concrete Road which includes Laying C C road slab 100mm thick in 1:2:4 cement, coarse sand and 20 mm stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge. |
| 103 | P.C.C. (1:4:8) in base concrete 75 mm thick in cement, course sand and 40 mm th. Stone ballast including supply of all labour, material, T&P etc. complete as per direction of engineer in charge. |
| 104 | C.C.Tiles Road which includes Laying of 80mm thick C.C soling including dressing surface and including supply of tile, filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work with P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast. |
| 105 | Survey site Investigation Planning, design Drawings (crossing length 15m to 20m ), Road for of required dia Rising main and distribution pipe with casing pipe as required for proper completion of work required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron PU coating internally and 250 micron anti corrosive bituminous paint externally by trenchless technology method at an average depth 2.0 mtr from normal ground level up to top of casing pipe including excavation & filling of Pit, Dewatering arrangement, Supporting system for soil, all complete work including supply & fixing specials in carrier pipe over main pipe, including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer in charge |
| 106 | Road crossing for 200 mm dia pipe |
| 107 | Road crossing for 350 mm dia pipe |
| 108 | Supply of all material like HDPE pipe 20mm (OD), GI pipe 15 mm dia, clamp with saddle, all specials, brass ferrule, bibcock as per relevent IS specification for making house connection with distribution main including dismantling of road, supply, carting of specials, lowering them into trenches, fixing them in proper alignment and jointing including bailing out of water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. |
| 109 | 90 mm to 125mm dia HDPE Pipe |
| 110 | Supply of all material like HDPE pipe 20mm (OD), GI pipe 15 mm dia, clamp with saddle, all specials, brass ferrule, bibcock as per relevent IS specification for Shifting of water house hold connections including dismantling of road, supply, carting of specials, lowering them into trenches, fixing them in proper alignment and jointing including bailing out of water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. |
| 111 | 90 mm to 125mm dia HDPE Pipe |
| 112 | 140 mm to 180 mm dia HDPE Pipe |
| 113 | 200 mm to 250 mm dia DI K-7 Pipes |
| 114 | 300 mm to 350 mm DI K-7 Pipes |
| 115 | 400 mm to 500 mm DI K-7 Pipes |
| 116 | BUILDING WORK |
| 117 | Excavation in foundation in ordinary soil (loam,clay or sand) including lift up to 1.50 m & lead up to 50 m,refilling,watering and ramming of evcavated earth into the trenches or space betwwen the building and sides of foundation trenches or into the plinth and disposal of surplus earth anydistance inside gram panchayat boundary as per site engineer instructions. |
| 118 | Concrete with 40 mm gauge brick ballast,local sand and cement in proportion in 12:6:1 in foundation including supply of all material,labour T & P etc. required for proper completion of work. |
| 119 | Concrete with 40 mm gauge brick ballast,local sand and cement in proportion in 8:4:1 in foundation including supply of all material,labour T & P etc. required for proper completion of work. |
| 120 | Ist. Class brick work in 1:6 cement and local sand mortar in foundation and plinth including supply of all material,labour T & P etc. required for proper completion of work. |
| 121 | Ist. Class brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all material,labour T & P etc. required for proper completion of work. |
| 122 | 20 mm thick D.P.C.with cement and approved coarse sand 1:2 including 5% water proofing material or in proportion as specied by the manufactures including supply of all material,labour T & P etc. required for proper completion of work. |
| 123 | Ist. Class brick work in 1:6 cement and coarse sand mortar in super structure including supply of all material,labour T & P etc. required for proper completion of work. |
| 124 | Ist. Class brick work in 1:4 cement and coarse sand mortar in super structure in half brick thick wall including supply of all material,labour T & P etc. required for proper completion of work.Ist. |
| 125 | Supply and fixing of M.S. angle iron chaukhats of 40 mm x 40 mm x 5 mm with 20 gauge M.S. sheet door shutter including simple moulding straightg work as in chaukhats and also supply of all material,labour T & P etc. required for proper completion of work. |
| 126 | Supply and fixing of M.S. angle iron of 50 mm x 50 mm x 6 mm post as per drawing including two coat of painting(4.15m length @4.5kg/m) T & P etc. required for proper |
| 127 | Fixing of hold fast of door and windows choukhats already moulded on choukhats in PCC 1:2:4 etc. required in all respect to complete of work. |
| 128 | R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of 1:1.5:3 in sun shed and lintel on doors and windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all material,labour T & P etc. required for proper completion of work. |
| 129 | R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of 1:1.50:3 in slabs excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all material,labour T & P etc. required for proper completion of work. |
| 130 | M. S. or Iron work in plain work such as R.C.C.or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and its wastage. |
| 131 | Supply and fixing of Z- Section section window frames fitted with M.S. bar grill and Shutters openable outside as per drawing and design approved by E/I, hinges of approved quality,M.S. or C.I. handles,hold fast 4 nos of M.S. flat 25x5 mm and 150 mm long, pegs of M.S. 30 cm long having 4 holes with pagester and brackets welded or riveted to frame complete including the cost of Glass Panes & including supply of all material,labour T & P etc. required for proper completion of work. |
| 132 | 12 mm thick plaster with cement and coarse sand mortar I:6 over brick work minimum thickness not to be less than 10 mm including supply of all material,labour T & P etc. required for proper completion of work. |
| 133 | 12 mm thick plaster with cement and coarse sand mortar 1:4 over ceiling including supply of all material,labour T & P etc. required for proper completion of work. |
| 134 | Supply and fixing of 5 mm thick and 20 mm wide glass strips in panels including supply of all material,labour T & P etc. required for proper completion of work. |
| 135 | 25 mm thick 1:2:4 cement concrete floor with cement coarse sand and 20 mm gauge stone ballast laid in pannels finished with 3 mm floating coat of neat cement or cement and marble dust in ratio 1:5 as specified and removing any overlaping or mortar at the joints of panels if any and giving them uniform finish over 80 mm thick PCC 1:4:8 base concrete including supply of all material,labour T & P etc. required for proper completion of work. |
| 136 | Painting or varnishing new work or new wood work in small areas with one priming coat and two coat of approved quality paint or varnish including supply of all material,labour T & P etc. required for proper completion of work. |
| 137 | White washing three coat including supply of all material,labour T & P etc. required for proper completion of work. |
| 138 | Finishing walls with water proof cement paint of approved make (Apex painting) and quality on new work with two coats to give an even shade including supply of all material,labour T & P etc. required for proper completion of work. |
| 139 | Supply and fixing of Girder (ISMB) of 225 mmx110 mm size over the pump house including its painting with approved quality paint and also one priming coat. |
| 140 | Sand filling in plinth staff quarter pump house and chloronating room including supply of all material,labour T & P etc. required for proper completion of work. |
| 141 | Supply and lay 4 cm thick insulation layer of sand and clay over R.C.C. roof including supply of all material,labour T & P etc. required for proper completion of work. |
| 142 | Supply cutting and dressing with size and fixing V-Notch of size 90 x90 cm in the by pass chamber as per direction of E/I including supply of all material,labour T & P etc. required for proper completion of work. |
| 143 | Mud Faska on R. B. or R.C.C. Roof with 100 mm thick clay layer on roof and laying of tiles and jointing them with cement and sand mortar including supply of all material,labour T&P etc. complete. |
| 144 | Supply & Fix 110 mm dia P.V.C. down pipes complete with rose & bend and gratings with M.S. clamps 25 X 3 mm fixed on walls & supply of 150 mm long, 6 mm dia nails complete. |
| 145 | Construction of R.C.C. manhole cover 70x70x10 cm for opening in roof slab and fixing it at opening including supply of all material,labour T&P etc. complete. |
| 146 | Provide and fix R.C.C jalies of size 30x30cm and fixing of R.C.C. jalies and plastering the same including supply of all material,labour T&P etc. complete. |
| 147 | Earth filling in campus including its cost and cartage up to site of work complete including supply of all material, labour T&P etc. complete |
| 148 | Provision of Internal electrification (conceiled fitting) in PUMP HOUSE suitable 5 Amp light points in each room/verandah/nd 15 Amp Power points with latest ISI fittings & fixtures like LED lights, PVC insulated 2.50 mm copper wires for L/F points & 4.00 mm for power points and also supply & fixing of main switch boards( MCB Box) of approved quality in each pumphouse as per direction of engineer-in-charge including supply of all material,labour,T&P etc. complete.(other specifications and details can be get from engineer-in-charge.) |
| 149 | Fixing of 3.6 m wide M.S gate with 1.0 m wide wicket gate as per departmental type design and drawing including fabrication, supply and construction of boundary pillars etc all complete.including supply of all material,labour T&P etc. complete as per direction of engineer in charge. |
| 150 | M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 151 | (1046) 115 mm string or drip coarse of Ist.Class brick in 1:6 cement and local sand mortar including plastering, cutting drip notch as required and including supply of all material,labour T&P etc. required for proper completion of work. |
| 152 | (1201) 20 mm thick plaster in dado or skirting in 1:2 cement and sand mortar including supply of all material ,labour T & P etc. required for proper completion of work. |
| 153 | (1206) Same as item no 1202 but without base concrete.pcc flooring |
| 154 | (1161&1162) Same as item no 1161 but pcc in Apron. |
| 155 | provision for water supply and sanitary works including supply of all ISI marked fittings such as automatic WC, wash basin, sink , faucet or mixter tap for hot and cold water material, labour,T&P etc. complete as per aproved by E/C in staff quarter and Office cum lab. |
| 156 | provision for internal electrification including supply of all ISI marked material such copper wire ,modern board, switch ,up to maximum 10nos electric points,ceilling fen and exhaust fen with, ceilling round or sqare led lights ,under ground conduit wiring , including all labour,T&P etc. complete in all respect.in each rooms of staff quarter and lab etc as per direction of engineer-in-charge including in staff quater room and lab .5 Amp light points in each room/verandah/nd 15 Amp Power points with latest ISI fittings & fixtures like LED lights, PVC insulated 2.50 mm copper wires for L/F points & 4.00 mm for power points and also supply & fixing of main switch boards( MCB Box) of approved quality in staff quarter and Office cum lab. |
| 157 | Supply of barbed wire |
| 158 | (1159) Fixing of barbed wire fencing post to post in 4 rows with two cross rows 12x12 gauge after stretching it including labour, T&P etc. required for proper completion of the work. |
| 159 | (1015) Cement concrete with 20 mm gauge stone ballast, coarse sand and cement in proportion of 4:2:1 including supply of all material,labour T & P etc.required for proper completion of work. In column of baundry wall. |
| 160 | Construction of 80 mm thick CC Tile approach road over 1:6:12 base concrete including preparation of subgrade etc. complete and spreading 40mm thick local sand including supply of all material,labour T & P etc. required for proper completion of work. |
| 161 | Recharge of ground water by roof top rain water of pump house and staff quarter, water available from bye pass of tube well and over flow of over head tank as per drawing including supply of all materials,labour, T&P etc complete (withwater taping arrangement from roof) |
| 162 | Provision of solar street light with m. s pole 200 W led , automaticaly turn on off etc as per direction of engineer-in-charge including supply of all material,labour,T&P etc. complete.grouting in pcc 1:1:2 (other specifications and details can be get from engineer-in-charge.) |
| 163 | E&M WORK |
| 164 | Drilling of borehole for Tubewell construction by RC Rig machine including transportation, erection, dismantlling of Rig and associated T&P Complete in all respect inculding required all material, labour etc |
| 165 | Transportation, Erection, Dismantling of Rig Machine and its T&P |
| 166 | Drilling by RC RIG machine 600mm dia |
| 167 | 0 to 66 mtr. Deep |
| 168 | 66 to 100 mtr. Deep 500mm dia |
| 169 | 100 to 170 mtr. Deep 500mm dia |
| 170 | M.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe (as required upto 50% of plain pipes) rings, well cap bail plug, clamp reducer, central guide, suport structure etc. as required & as per typed design complete in all respect. |
| 171 | 300 mm dia M.S. ERW Housing casing Pipe having wall thickness of 7.1mm |
| 172 | 200 mm dia M.S. ERW Housing casing Pipe having wall thickness of 7.1mm |
| 173 | Supply of Pea Gravel |
| 174 | Logging of borehole by departmental/approved electric logger |
| 175 | Lowering of tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all repect |
| 176 | Lowering of 300mm dia pipe from GL to 60m deep BGL |
| 177 | Lowering of 200mm dia pipe from 60 to 100m deep BGL |
| 178 | Lowering of 200mm dia pipe from 100 to 165m deep BGL |
| 179 | Development of tube well by Air Compressor. |
| 180 | Transportation, installation and dismantling of 350 PSI Compressor |
| 181 | Development of tube Well by adequate capacity Air compressor |
| 182 | Development of tube well by O.P Unit |
| 183 | Transportation, installation and dismantling of 3 Cusec O.P. Unit and Yield test |
| 184 | Development of tube Well by adequate capacity by O.P Unit |
| 185 | Chemical and Bacteriological test of water sample from departmental approved lab |
| 186 | Baricading/fencing of the site during the construction of tubewell to ensure that site is not exposed to risk to accident |
| 187 | RENOVATION OF EXITING PUMPING PLANT FOR ZONE 5A TW -1&2 |
| 188 | SITC of submersible pump of 1500 LPM 64M Head 35 HP |
| 189 | Dismentling of old Pumping plant for site and carting upto nagar palika store |
| 190 | CE & UL certified hydrostatic type sub soil water level transmitter for tubewell |
| 191 | Reparing and Overhauling of sluice valve with actuator of 150mm size |
| 192 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
| 193 | SITC OF NEW PUMPING PLANT FOR ZONE-7A TW 1&2 |
| 194 | SITC of submersible pump set with 24 mtr coloumn pipe, NRV,CI D/F Bend 90 deg., CI A/F Tee, D/F pipe (1.5 met long-2 Nos and 1 met long- 1 No ), Earthing, Painting,Toolset, wiring of pump house (with internal&external electrification),chainpully block and all pumping plant accessories with nut bolts and rubber packing etc (all other items for pumping plant item not included in SCADA Automation pumping plant items.) |
| 195 | Servo voltage stabilizer (240v-500v) 75 kva |
| 196 | 6mtr long heavy duty size 150mm dia Coloumn Pipe same as above spare (for 18mtr length) |
| 197 | Copper cable size 2x3cx10sq. mm. flat for 18m extra column pipe. |
| 198 | 4x50 sq. mm AL cable for power connection |
| 199 | Automatic chlorination system |
| 200 | Soft starter with RS 485 Port-400V Class 45 kw rating |
| 201 | auto Phase reversal unit with inbuilt time delay and enclosure (125amp). |
| 202 | CE/UL certifeid Intelligent Smart Energy Meter |
| 203 | CE/UL Certifeid Electromagnetic Flow Meter 150 mm size |
| 204 | CE/UL Certifeid hydro static type sub soil water level transmetter for TW |
| 205 | CE/UL Certifeid Pressure Transmitter |
| 206 | CE/UL Certifeid Surge protector control panel |
| 207 | Motor operated Actuator with sluice valve/flow control valve 150mm size. |
| 208 | CE/UL Certifeid 7\\" hmi touch screen suitable to communication with PLC/RTU for display & control of process parameters |
| 209 | CE/UL Certifeid Surge protector control panel |
| 210 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT |
| 211 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 212 | RENOVATION OF EXITING CWR-ZONE-7B&7C PRAHLAD NAGAR (GOLAKUAN) (for CWR to 500 KL New OHT) |
| 213 | Cast iron pipes & specials. |
| 214 | Supply of galvanized nut-bolt SS-304 and rubber packing material for erection of above @ 5% of total weight |
| 215 | Reflex Valve |
| 216 | CIDF double flanged single/multi door swing check valves PN 1.0 FG 200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces, diaphragm plate and door, sub pins and shall be of following sizes. |
| 217 | 150 mm dia |
| 218 | 150 mm dia |
| 219 | Motor operated Actuator with sluice valve/flow control valve 150mm size at delivery line of each pump (2W + 1S) |
| 220 | Motor operated Actuator with sluice valve/flow control valve 150mm size at common header |
| 221 | CI Dismantling joints |
| 222 | 150 mm dia |
| 223 | 150 mm dia |
| 224 | CE/UL Certifeid Electromagnetic Flow Meter suitable for line size 150 mm |
| 225 | CE/UL certifeid Intelligent Smart Energy Meter for each pump |
| 226 | Automatic chlorination system compactable to SCADA system |
| 227 | CE/UL Certifeid Pressure Transmitter for each pump |
| 228 | CE/UL Certifeid Surge protector control panel |
| 229 | auto Phase reversal unit with inbuilt time delay and enclosure (125amp). |
| 230 | 40HP VFD panel for each pump |
| 231 | Power Cables |
| 232 | 1100V Grade, 2x3cx10 sqm PVC insulated PVC sheathed submersible copper conductor cable from LT Pannel to motor 3 Nos. pumps (2x3x40 mtr) |
| 233 | For CWR to 400 kl New OHT |
| 234 | Supply of Electric Driven self water lubricated V.T. pumping set 850 LPM 39 mtr head complete in all respect with discharge head assembly and strainer complete with 12.5 HP VHS induction 50hz 3 phase AC supply 415 +6%-10 volts at speed 1470 RPM(a)Capacity 14.16 LPS/850LPM(b)Total Head 39mtr(c) Delivery size 100mm |
| 235 | DI pipes and specials |
| 236 | Supply of galvanized nut-bolt SS-304 and rubber packing material for erection of above @ 5% of total weight |
| 237 | Reflex Valve |
| 238 | CIDF double flanged single/multi door swing check valves PN 1.0 FG 200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces, diaphragm plate and door, sub pins and shall be of following sizes. |
| 239 | 100 mm dia |
| 240 | 150 mm dia |
| 241 | Motor operated Actuator with sluice valve/flow control valve 100mm size at delivery line of each pump (2W + 1S) |
| 242 | Motor operated Actuator with sluice valve/flow control valve 150mm size at common header |
| 243 | DI Dismantling joints |
| 244 | 100 mm dia |
| 245 | 150 mm dia |
| 246 | CE/UL Certifeid Electromagnetic Flow Meter suitable for line size 150 mm |
| 247 | CE/UL certifeid Intelligent Smart Energy Meter for each pump |
| 248 | Automatic chlorination system compactable to SCADA system |
| 249 | CE/UL Certifeid Pressure Transmitter for each pump |
| 250 | CE/UL Certifeid Surge protector control panel |
| 251 | auto Phase reversal unit with inbuilt time delay and enclosure (100amp). |
| 252 | 15 HP VFD panel for each pump |
| 253 | Power Cables |
| 254 | 1100V Grade, 2x3cx6 sqm PVC insulated PVC sheathed copper conductor cable from LT Pannel to motor 3 Nos. pumps (2x3x40 mtr) |
| 255 | LT panel board confirming to IEC-60439 |
| 256 | L.T. Panel board sutibale for operation on 415 V, 3 phase 50Hz AC supply in sheet steel enclosure in cubical parttern floor mounting with following fitted on th face of the panel with bus incomer of 400 Amp capacity bus bar size of 40x10mm AL & Neutral half of the capacity sectionalized through a bus section. the panel shall comprise of the following |
| 257 | 01 no incoming feeder from one nos of transformer with following details. |
| 258 | 01 nos of 630 Amps MCCB with power contractor for phase reveral for one saparate transfromers incomer preferably L&T, shneider, ABB with phase indicators |
| 259 | one set of current transformers of ratio 600/5a |
| 260 | one set of multifunction metter for measuring Amp, Voltage Kwh,pf |
| 261 | 01 no incoming feeder from D.G. with following details. |
| 262 | 01 no suitable capacity MCCB with power contractor for D.G. incomer preferably L&T, shneider, ABB with phase indicators |
| 263 | one set of current transformers of ratio 400/5a |
| 264 | one set of multifunction metter for measuring Amp, Voltage Kwh,pf |
| 265 | 3 Nos of MCCB of rating 100 Amps with suitable capacity of contractor for 40 HP pump feeders with push button and indicators |
| 266 | 3 Nos of MCCB of rating 32 Amps with suitable capacity of contractor for 12.5 HP pump feeders with push button and indicators |
| 267 | 01 nos MCB of rating 63 Amps and 01 no of MCB of rating of 32 Amps |
| 268 | one set of 25 Kvar Capacitor section APFC relay & other accessories |
| 269 | Double girder 3.0 tone EOT crane with wire rope hoist. Height of lif 6.0 mtr of transverse & longitudinal motion both |
| 270 | CE/UL Certifeid Radar type water level Transmitter for CWR |
| 271 | Control Cables |
| 272 | Control cable 1x10c 1.5sqmm PVC insulated PVC sheathed copper conductor cable from moisture sensor reveres protection thermistor relay etc |
| 273 | Earthing |
| 274 | Complete earthing of all equipments as deailed above shall be done as per IS/IER/PWD specification with G.I. plates, watering pipe and loop cutting with adequate size of G.I./A.L stripe etc(P.S. 702) 06 pits for 2 each of the equipment (1 no LT panel) size of earthing plate 600mmx600mmx6mm with salt and coal |
| 275 | Lighting system |
| 276 | Supply and eriction of M.S tubular poles SP-36, 9.5mtr height |
| 277 | S/F of 72watt LED with lumen reflector |
| 278 | Feeder pillar for lighting |
| 279 | Supply and laying of 4x16sqmm AL. armoured cable |
| 280 | Internal Electrification with fixtures |
| 281 | S/F 1200mm Ceiling fan for L.T. room |
| 282 | S/F of exhaust fan for L.T. room |
| 283 | Earthing of street light pole (SOR-41) |
| 284 | Painting of street light (P5-634) |
| 285 | Supply and installation of DCP type of 5 kg fire existinguisher(PS-1132) |
| 286 | 12mm thick rubber mating for safe working on (1mx2m) |
| 287 | Tools |
| 288 | Hydrulic crimping tools |
| 289 | Mannual crimping tools |
| 290 | Tong tester, multimeter megger, screwdriver, plier |
| 291 | Chain wrench & pipe wrench |
| 292 | Installation, of above equipments and panels etc. complete |
| 293 | commissioning and testing of above equipments and panel etc. |
| 294 | chequered palte of required size so as to cover all trenches |
| 295 | SUBSATATION OF EXISTING CWR |
| 296 | Power Distribution Transformer |
| 297 | Testing of oil immersed oudoor type power distribution tranformer 11/0.433KV rating existing 125 kva double wound with copper winding level-1 vector group dyn 11, ONAN with manually operated +/- 5.0% off load tap changer in step of 2.5% and complete with standard fitting and accessories |
| 298 | supply and laying of 1100voltage grade, 1x3.5cx240sqmm AL conductor, XLPE armoured cable core from transformer to LT panel |
| 299 | Double earthing of transformers consistingof 04 nos earthing pit (two for each neutral and body) with AL/GI strip size 50x6mm, the minimum distance between to earthing pits double earthing works and all electrical equipments shall be as per IS&IER |
| 300 | Installation Testing & Commissioning of Transformer Complete |
| 301 | H.T. Switch Gear. |
| 302 | Supply of 12 KV, H.T. V.C.B. Panel with one incoming & one out going, 630 amp(25KA rating have following) |
| 303 | Incommer Feeder-01 No. |
| 304 | 3 O/C + 1 EF IDMT characteristies relays based Incommer control panel equiped with over cerrunt and earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc. C.T. ratio 30-20/5A,Dual core, Class-I for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20 & volt meter 0 to 12 KV. All relays required separately conventional type 24 to 30 VDC, 110 VAC. |
| 305 | Outgoing Feeder-02 Nos. |
| 306 | Outgoing Feeder control panel equiped with triple pole 2 O/C +1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm/trip, OTI alram/trip & WTI alram/trip, etc. C.T. ratio 30-15/5A, Class-I for measurement core & 5P10 for protecton core. |
| 307 | D.C. Supply |
| 308 | SITC battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable MS Stand/Trolly, equipment fitting with accessories etc |
| 309 | supply and laying of , 1x3cx70sqmm 11KV HT AL, XLPE cable from metring panel to HT panel and from HT panel to bought transformer |
| 310 | S/F of XLPE cable and tramenation box of 70sqmm |
| 311 | Indoor end tramitation box |
| 312 | Earthing of HT panel as per IS & IER |
| 313 | Erection of substation equipments and fencing with iron mesh etc. complete in all respect |
| 314 | Commissioning and testing of all sub station equipments etc. complete in all repect |
| 315 | E/M WORK OF OHT FOR ZONE 5,6&7 |
| 316 | Motor operated actuator with sluice valve on new OHT of 250mm size of zone 5A |
| 317 | Motor operated actuator with sluice valve on new OHT of 350mm size of zone 7A |
| 318 | Motor operated actuator with sluice valve on new OHT of 250mm size of zone 7B&7C |
| 319 | Flow meter on OHT delivery line of size 250mm dia for new OHT of Zone 5A |
| 320 | Flow meter on OHT delivery line of size 350mm dia for new OHT of Zone 7A |
| 321 | Flow meter on OHT delivery line of size 250mm dia for new OHT of Zone 7B&7C |
| 322 | CE/UL certified Radar type Level Transmitter for new over Head Tank |
| 323 | Chlorine Analyzer rnge 0-5ppm (electrolyte with membrane cap Type Amperometric |
| 324 | CE/UL Certifeid 7\\" HMI touch screen suitable to communication with PLC/RTU local display & control of process parameters for Zone-7C |
| 325 | Electricity charges for 03 month trial run period |
| 326 | COST FOR UPGRADATION OF EXISTING MCS |
| 327 | Provision of Upgradation of existing MCS for incorporation of new tubewell existing CWR data and other necessory rarameters with new hardware required if any so that complete scheme may operate with the MCS complete in all respect |
| 328 | SCADA FOR PUMPING PLANT FOR ZONE-7A TW 1&2 |
| 329 | CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog anddigital parameter and features as specifeid for each tubewell/OHT and stand alone OHT to store and transmit data on GSm backbone RTU/PLC designed with logic to transfer data at multiple statiuonas. |
| 330 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote site to controlstation all accessoreis included with signalenhancer antenna made for pumping plant internet charges |
| 331 | Installation, commissioning & testing for one TW/OHT |
| 332 | trial for 3 months period for one tubewell |
| 333 | SCADA SYSTEM FOR URBAN C.W.R HAVING 03 NOS PUMPS |
| 334 | CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog anddigital parameter and features as specifeid for each ZPS/OHT to store and transmit data on GSM backbone RTU/PLC designed with logic to transfer data at multiple statiuonas. |
| 335 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote site to controlstation all accessoreis included with signalenhancer antenna made for pumping plant internet charges |
| 336 | CE/UL Certifeid 7\\" hmi touch screen suitable to communication with PLC/RTU local display & control of process parameters |
| 337 | Complete cabling of CWR including all power and control cables of all equipment at CWR and OHT |
| 338 | Installation, commissioning & testing for CWR |
| 339 | trial for 3 months period for one CWR |
| 340 | SCADA OF OHT FOR ZONE 7C |
| 341 | CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specifeid for each TW/OHT & stand alone OHT to store and transmit data on GSM backbone RTU/PLC designed with logic to transfer data at multiple statiuonas for STANDALONE OHT |
| 342 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote site to control station all accessoreis included with signalenhancer antenna made for pumping plant internet charges |
| 343 | CE/UL Certifeid suitable capacity UPS with batteries at each OHT for proper working of actuator valve and other SCADA items at the time of electricity failure |
| 344 | 3 MONTH TRIAL & RUN |
| 345 | 3 MONTH TRIAL RUN OF PUMPING PLANT FOR ZONE 5A, TW 1&2 INCLUDING CHLORINATION |
| 346 | 3 MONTH TRIAL RUN OF PUMPING PLANT FOR ZONE 7A, TW 1&2 AND 7B, INCLUDING CHLORINATION |
| 347 | 03 MONTH TRIAL RUN OF E/M WORKS AT CWR ZONE 7C |
| 348 | COST OF OPERATION DURING TRIAL & RUN PERIOD |
| 349 | Cost of operation through scada for all tubewells & CWR Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail