| 1 | M&L for cleaning/clearing & maintenance of under ground sewage lines by manually or mechanically in any depth by removing of any type of blockage from sewage drain upto and incl 300mm dia of bore by rodding or any other means manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning incl intermediate manholes. sludge water in form of semi solid/loose state will be disposed off the same(semi solid/liquid shall not be burried) including taking off manhole cover and refixing the same after cleaning. The operation shall be executed/carried out with any kind of sewage cleaning device to be included in the rate quoted by the contractor complete all as specified and as directed. |
| 2 | M&L for cleaning of blocked WC/Gully trap/Floor trap/Nahani trap upto and including first manhole by manual labour as well flushing with clean water making the WC seat, gully trap, floor trap operational complete all as specified and as directed by Engr-in-Charge. |
| 3 | Taking out semi soild, liquid suspension sludge and foreign material from man hole/septic tanks/soakage well of any description and any depth including pumping out of water and removing materials either by the same in covered van or trolley at out side MoD land and burring the same (semi solid/liquid shall not be burried) in ground inc complete all as specified and as directed. (Note: The location at outside MoD land for disposal of forieign materials obtained above shall be located by the contractor himself) |
| 4 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation for shafts, wells, cesspits, manholes, pier holes, pole etc n.exc 10sqm on plan and getting out soft/loose soil complete all as specified and as directed. |
| 5 | M&L for PCC type D-2,1:4:8 (40mm graded aggregate) as in foundation, filling in mass concrete etc complete all as specified and as directed. |
| 6 | M&L for PCC 1:3:6 type C2 (using 40mm graded agg) concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm dia of bore pipe including demolition of existing old one with PCC complete all as specified and as directed. |
| 7 | -Ditto- all as per item No 6 here in before but 200mm dia of bore |
| 8 | -Ditto- all as per item No 6 here in before but 300mm dia of bore |
| 9 | M&L in repair for 150mm bore RCC pipes, class NP2 laid and jointed with collars and tested including demolition of existing old one (salt glazed earthware, AC or reinforced pipes etc) set in cement mortar complete all as specified and as directed. |
| 10 | -Ditto- all as per item No 9 here in before but 200mm dia of bore |
| 11 | -Ditto- all as per item No 9 here in before but 300mm dia of bore |
| 12 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting our existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC(1:2:4) type B-1, smooth finished and reforming benching as required for any dia of pipe complete all as specified and as directed. |
| 13 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 14 | M&L for pre-cast cement concrete block masonry with solid blocks exc. 10 cm in width, type C-1,1:3:6 (using 20mm graded agg) and setting in cement mortar 1:6 complete all as specified and as directed. |
| 15 | M&L for PCC type B-1, 1:2:4 (20mm graded agg) as in copings, kneelers, apex stones,bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as directed |
| 16 | M&L for 15mm thick plastering in CM 1:4 on brick or concrete wall surfaces fair and even with 2% of WPC on cementcomplete all as specified and as directed.(Note:WPC shall be measurned and paid in separatetly) |
| 17 | Supply only integral water proofing compound |
| 18 | M&L for preparation of new plastered wall surface of any description, width or girth, and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 19 | Demolition of cement concrete(un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 20 | M&L for 100mm thick PCC type D-2(1:4:8) as in sub base on rammed earthcomplete all as specified and as directed. |
| 21 | M&L for machine pressed precast cement concrete coloured interlocking paver blocks, glossy rubber moulded, of triangular / Zigzag / Haxagone/any shape/design and size as approved, 60mm thick, conforming to IS 15658-2006, M-35 with grey cement and pigments grade in floor/ paths/ pavement laid over and including 25mm thick sand cushioning laid dry to the profile including filling the joints with sand including dismantling of existing tiles of any description complete all as specified and as directed. NOTE: (i) Manufacturers test certificate shall be submitted alongwith sample. |
| 22 | M&L for pre polished chequred tiles of size 300x300x25mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing floor and including 20mm thick screed bed and bedding of layers in CM 1:6 including demolition of existing tilescomplete all as specified and as directed. |
| 23 | M&L for demolition & complete removel of sunken floor, water proofing plaster coated with bitumen as special water proofing slurry coat as per manufacturer instruction all concrete/ brick surfaces & fixed 40mm bore spout pipe on external wall with proper sealing plaster and after drying the floor fiixed of IWC with CI pipe, joints with special plastic sealant to prevent shrinkage and allow some movement then 40mm thick PCC 1:3:6 type C2(20mm graded agg) over filled with dry lean concrete 200mm thick M-5, type E2 (40mm graded agg) as in sunken floor complete all as specified and as directed by Engr-in-charge |
| 24 | S&F in repair 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on wall incl GI clamp with screw complete all as specified and as directed Make:ISI marked |
| 25 | -Ditto- all as per item No 24 here in before but 75mm dia fixed on wall complete all as specified and as directed. |
| 26 | S&F in repair 110mm dia PVC (SWR) bends in any radius fixed with pipecomplete all as specified and as directed Make:ISI marked |
| 27 | -Ditto- all as per item No 26 here in before but 75mm dia fixed on wall complete all as specified and as directed. |
| 28 | S&F in repair 110mm bore PVC (SWR) branch piece, single (Y) equal or unequal fixed on wall complete all as directed |
| 29 | -Ditto- all as per item No 28 but 75mm bore |
| 30 | S&F in repair 110mm bore PVC (SWR) junction, single (T) equal or unequal fixed on wall complete all as directed |
| 31 | -Ditto- all as per item No 30 but 75mm bore complete all as specified and as directed. |
| 32 | S&F in repair 110mm bore PVC cowl complete all as specified and as directed. |
| 33 | S&F in repair 75mm bore PVC cowl complete all as specified and as directed. |
| 34 | S&F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including P-trap (PVC) 100 mm dia., connection to flushing pipe, anti-syphonage pipe complete incl making good to floor complete all as specified and as directed. |
| 35 | S&F in repairs Vitreous China wash down water closet pan (pedestel pattern) white including trap, connection to drain (outgoing pipe) and to flushing pipe, anti-syphonage pipe, including PVC jet for Pedestal pattern pan including 450/600mm long PVC connection including PTMT nuts and plastic water closet seat of white in colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device etc complete all as specified. |
| 36 | S&F in repair vitreous china half stall type, white bowl urinal flat back white including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement paste, incl 5Ltrs capacity PVC automatic flushing cistern with brackets 32mm dia PVC flush pipe and discharge pipe, grating and union for discharge pipe complete all as specified and as directed. |
| 37 | S&F in repair 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float ovel handle including brackets and PVC flushing pipe of polyethylene of low or high density or PVC 32mm dia complete all as specified and as directed. Make : Cera/Prayag/Johnson Pedder. |
| 38 | -Ditto- all as per item No 37 here in before, but 100mm dia gratings complete all as specified and as directed. |
| 39 | S&F in repair chromium plated gratings 100mm dia with drain hole complete all as specified and as directed. Make: ISI Marked or of equivalent make as per Appx'A' as approved by GE |
| 40 | S&F in repairs hand shower (health faucet) of cast copper alloy chromium plated with 8mm dia, 1.2m long flexible tube and wall hook complete all as specified and as directed by Engr-in-charge. Make : Cera/Prayag or of equivalent make as per Appx 'A' as approved by GE |
| 41 | S&F in repairs bip taps standard of PTMT any colour 15mm bore min wt 90gms Make: Prayag or equvalent of ISI marked complete all as specified and as directed. |
| 42 | S&F in repairs pillar taps suitable for 15mm bore pipe long body fancy type brass CP with screwed down screwed for iron pipe or brass ferrule quarter turn complete all as specified and as directed. Make: Johnson VIVA new series Cat Pt No: T4801C or of equivalent make as per Appx 'A' as approved by GE. |
| 43 | S&F in repairs, chromium plated bib cock with wall flange quarter turn complete all as specified and as directed. Cat No. FUS-29037 of make Jaquar ‘Fusion' series or of equivalent make as per Appx 'A' as approved by GE. |
| 44 | S&F in repair angle cock with flange quarter turn chromium plated cast copper alloy ISI marked, high pressure screwed down complete all as specified and as directed. Make: Johnson Eco Cat part No: T3910C or of equivalent |
| 45 | S&F in repairs two way bib taps with wall flange quarter turn suitable for 15mm bore pipe long body fancy type brass CP, screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed. Make Johnson VIVA new series Cat part No: T4808C or of equivalent make as per Appx 'A' as approved by GE. |
| 46 | S&F in replacement 75/100mm bore PVC (SWR) floor trap plain with CP grating including jointing with solvent cement to waste pipe fixed in cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate complete all as specified and as directed. |
| 47 | S&F for rotational moulded polyethylene water storage tank 3 layer white colour water tank , non- toxic effect, algea formation protection (made frome virgin grade of polyethy-lene material which is duly stablized with anti-oxident plastic) of capacity 500 litres, cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,20 mm dia PTMT valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and 20 mm brass stop cock etc complete including dismantling existing water tank complete all as specified and as directed. Make: Sintex, Polycon, Rotex |
| 48 | -Ditto- all as per item No 47 here in before but 1000Ltrs capacity complete all as specified and as directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge |
| 50 | M&L non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm but not exc 0.09 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 51 | M&L for glazed ceramic tiles in vertical surfaces 450x300x7-8mm thick cement slurry and pointed in white or coloured cement to match with existing floors on10mm thick plaster in CM 1:3 complete all as specified and as directed. |
| 52 | M&L cutting chases pinning in brick work for concealing water tubing and making good to facing where required and pointing in cement motar 1:3, cutting n.exc. 10cm girth complete all as specified and as directed. |
| 53 | S&F 15mm bore tubes med grade galvanized ISI marked with all fittings in short length and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing complete all as specified and as directed. |
| 54 | All as per Srl item No 53 here-in-before, but taking down and fixing only complete all as specified and as directed. |
| 55 | S&F 20mm bore tubes medium grade galvanized ISI marked with all fittings in short length and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing complete all as specified and as directed. |
| 56 | All as per Srl item No 55 here-in-before, but taking down and fixing only complete all as specified and as directed. |
| 57 | S&F in repair 20mm bore gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. Make:ISI marked |
| 58 | S&F in 15mm dia of bore PVC connection fixed with iron pipe with PTMT nuts in 450mm long Make:Prayag/Polytuf complete all as specified and as directed. |
| 59 | Ditto- all as per item No 58 here in before but 600mm long complete all as specified and as directed. |
| 60 | S&F in repair plastic closet seat white closed pattern with flat bottom and cover and mild asteel chromium plated hinging device for pedestal pattern WC/semi pedestal and WC (anglo indian type) complete all as specified and as directed. |
| 61 | S&F in repair PVC tank cover of PVC water storage tank of any capacity complete all as specified and as directed Make:Sintex/Polytuf |
| 62 | S&F in repair 32mm dia PVC waste pipe for WHB, kitchen sink of length 1.0mtr incl coupling incl fixing the same complete all as specified and as directed. Make;Prayag or ISI marked |
| 63 | S&F for factory made 50mm thick, 950mmx650mm manhole cover with additional frame for fixing, of fixing of pre cast RCC 1:2:4 type B-1 (using 20mm graded agg) finished the surface even and fare including reinforcement MS TMT bars 8mm dia @ 125mm centre to centre bothways and set in CM 1:4 and handles including demolition of RCC (reinforcement cut as required to facilitate demolition) of any description and in any position complete all as specified and as directed. |
| 64 | -Ditto- all as per item No 63, here in before but 600mmx450mm size complete all as specified and as directed. |
| 65 | Removing of vegitation/plantation on the wall, roof or any description upto three stories of building including necessary scaffoldings and roots superficial area n.exc 2.0sqm each and making good of surfaces by applying chemical treatment with GLYPHOSATE 41% incl removing / refixing of GI/CI pipe lines complete all as specified and as directed. (Note:Brick work, plaster and CI/GI lines shall be measured and paid separately) |
| 66 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. |
| 67 | Removing of excavated material (soil) to distance not exc.50metres and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. |
| 68 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |