| 1 | Supply and Erection of 2.5” dia. G.I. Pipe pole 4.5 Mtrs long.Supply, Fabrication & erection of 2.5” dia G.I. pipe pole having length 4.5 long, B class (medium) ISI marked. The pole shall be erected 3’ below ground level in 8” dia. RCC muff ready made. The gap between the pole and muff shall be filled with cement concrete in ratio of 1:2:4 and making required no. of holes in the pole including carriage of pole to the site of work including all labour and material required to complete the job including suitable size of nipple welded with the pipe. Material to be (Jindal, Hissar or better brand Only.)The cost includes a plinth of cement concrete of 12”x12” size and 2” thick. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 2 | Dismantling and Re-erection of G.I. pipe pole 7.5/9 Mtr. Long alongwith street light etc. & other material complete in all respect. The pole shall be erected 1.5 mtr. below the ground level in 8\\" internal dia ready made RCC muff. The gap between the pole and the muff shall be filled with the cement concrete 1:2:4. The cost includes all labour and material. The bottom portion upto 1.25 mtr of the pole should be painted with two coats of black bituminous paint after removing the dust. The job shall be completed to the entire satisfaction of Engineer-in-charge. |
| 3 | Supply and Erection of steel tubular pole 410 SP-6 conforming to IS-2713-1980, (Part 1 & II) having over all length of 7.5 Mtr and welded in 3 steps and having approximate Wt.92 Kgs with the followings:- a) The poll shall have cross-sectional length of 4.50,1.5,1.5 Mtrs.,b) The out side dia and thickness shall be 114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.25mtrs. below the ground level in 8” internal ready made RCC muff. The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.d) The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust.The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 4 | PAINTING & NUMBERING OF POLES 4.5/6 Mtr. LONG: -Painting of poles above ground level with two coats of black paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. DANGER shall be written on each pole on its two sides with red paint on yellow base such that it may be visible clearly from far. The job includes all type petty material require to complete the job to the entire satisfaction of Engineer-in-charge. |
| 5 | PAINTING & NUMBERING OF POLES 7.5/9 MTR. LONG: -Painting of poles above ground level with two coats of paint of Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. DANGER shall be written on each pole on its two sides with red paint on yellow base such that it may be visible clearly from far. The job includes all type petty material require to complete the job to the entire satisfaction of Engineer-in-charge. |
| 6 | G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (with charcoal or coke and salt). The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. |
| 7 | P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 8 | S&E of Outdoor type one side openable M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type handle and L-key locking arrangements (with 2 sets of L-key). A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia.The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation platform of size 900mm deep (450mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 9 | Painting of pedestal size 1200x900x350mm with P.O. red paint and DANGER written on it with yellow paint complete in all respect and bonding to the existing earth etc. and platform of cement concrete 1:2:4 around the pillar box of size 3’x2’x0’-4”. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 10 | Supply and Erection of Angle Iron of bracket of 3' long made out of Angle Iron of Size 35x35x6 & fixed on top of G.I. pipe (0.5) long 4'' dia angle to support the bracket complete in all respect with suitable clump and nuts/ bolts to the entire satisfaction of Engineer-in-charge. |
| 11 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930,/ IS-16205 part ii complete with fitting and cutting, jointing etc.direct in ground (depth as per the directions of Engineer in charge or upto 75cm below ground level) including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) Make Gemini, Rex, Duraline The entire satisfaction of Engineer-in-Charge of work. |
| 12 | Supply & Laying of DWC pipe 51/63mm without hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, /IS-16205complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 13 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable (Pvc Sheathed) loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (Pvc Sheathed) of make Havells/ Finolex/ Ecko/ Lapp/ Sunhome/ Polycab/ KEI/ Cirtina conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2018 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 4iii) Working Voltage – 1100 Viv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6vi) Insulation Thickness – 1.0mm (Nominal)vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mmix) Nominal size of Armoured Wire/Strip – 4x0.8mmx) Approximate O.D. – 22mmMaximum d.c. Resistance at 20 Deg. C – 1.91 ohm/kmThe work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 14 | S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 16”. b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box.c) The collar shall be provided with 2/3 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box.d) The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality.e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of SMC material of robust construction with double hinge, with MS side clamp, locking arrangement. There should be a terminal Strip (Thimble type) 30 amp, one no. Kitkat, rating suitable for minimum 4x16 sq.mm aluminum cable termination.The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect. |
| 15 | Dismantling Of Existing Old Damaged/ Broken Old Bollards Lights/ Cc Collar, Jallies Alongwith Junction Box, Wire And C.C Foundation to complete the job to the entire satisfaction of Engineer-in-Charge. The dismantled material shall be handed over to the JE-in-charge of store. |
| 16 | Supply & Erection of PVC Insulated sheathed) Copper Conductor Cable ISI marked size 3 core 1.5 mm2.Supply & Erection of ISI Marked PVC insulated 3 core 1.5mm2 cable of Copper Conductor (Sheathed) make Universal/ Finolex/ Lapp/ Polycab/ Havell's/ left bare/ sunhome in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 1.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 17 | Supply & Erection of Three Phase Aluminum Bus BarSupply & Erection of Three Phase Aluminum Bus Bar of size 300mmx25mmx5mm with L type fuse unit to be fixed on Porcelein insulators in the existing pedestal with required nuts, bolts & M.S. sheet. The fuse links should be equal to the number of out going circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 18 | Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons/ L&T/ Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. |
| 19 | S&E of Mouled Case Circuit Breakers (MCCB) of ratin 100 Amp with Breaking Cap30 kA, 415 Volts.Supply & Erection of 4 pole,38 kA, 32 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 20 | Erection of 45 Watt Post tops Garden LED light on 4.5 mtr pole. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 21 | Erection of high power 120 Watt (Max) LED Flood Light luminaries on 7.5/9 /16/16 mtr high mast / High electric pole.The work shall be executed to the entire satisfaction of Engineer-in-Charge. Please Enable Macros to View BoQ information |