| 1 | BOUNDARY WALL WORKS |
| 2 | Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq M On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. - All Kinds Of Soil |
| 3 | Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) |
| 4 | Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] |
| 5 | Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) |
| 6 | Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More |
| 7 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 5.9.1 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete |
| 8 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 5.9.6 Columns, Pillars, Piers, Abutments, Posts And Struts |
| 9 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 5.9.5 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers |
| 10 | Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) |
| 11 | 12 Mm Cement Plaster Of Mix : - 1:6 (1 Cement: 6 Fine Sand) - Outer Plaster |
| 12 | Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. |
| 13 | Applying Priming Coats With Primer Of Approved Brand And Manufacture, Havinglow Voc (Volatile Organic Compound ) Content. With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre |
| 14 | Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : 13.46.1 New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sq M) |
| 15 | Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y’ Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, C.C. Blocks Shall Be Paid Separately) |
| 16 | Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required 10.25.2 In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works |
| 17 | Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-Incharge.Made Of G.I. Wire Of Dia. 4 Mm, Pvc Coated To Achieve Outer Dia Not Less Than 5 Mm In Required Colour And Shade Made Of G.I. Wire Of Dia. 4 Mm, Pvc Coated To Achieve Outer Dia Not Less Than 5 Mm In Required Colour And Shade |
| 18 | ENTRANCE GATE WORKS |
| 19 | Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works |
| 20 | Painting Steel Work With Deluxe Multisurface Paint Given An Even Shade 2 Aur More Coat Applied @ .90 Ltr/10 Sqmt Over An Under Coat Of Primer Applied @ .80 Ltr/10 Sqmt Of Approved Brand And Manufacturer |
| 21 | Lettering With Black Japan Paint Of Approved Brand And Manufacturer |
| 22 | SITE DEVELOPMENT |
| 23 | Surface Dressing Of The Ground Including Removing Vegetation And InEqualities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. 2.28.1 All Kinds Of Soil |
| 24 | Earthwork In Hill Road (Hill Side Cutting) 1-1-1 Excavation In Soil In Hilly Area By Mechanical Means 1-1-1-A Excavation In Soil In Hilly Area By Mechanical Means Without Useinng Dozer Including Cutting And Trimming Of Side Slopes And Disposing Of Excavated Earth With A Lift Upto 1.5 M And A Lead Upto 20 M As Per Technical Specification Clause 1603.1 |
| 25 | Excavation In Hilly Areas In Ordinary Rock By Mechanical Means Not Requiring Blasting (With Out Dozer) Excavation In Hilly Area In Ordinary Rock Not Requiring Blasting By Mechanical Means Without Using Dozer Including Cutting And Trimming Of Slopes And Disposal Of Cut Material With A Lift Upto 1.5 M And Lead Upto 20 M As Per Clause 1603.2. |
| 26 | Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. |
| 27 | Excavating,Supplying,Stacking & Filling Of Local Earth (Including Royality) By Mechanical Transport Up To A Lead Of 5 Km, Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches,Plinth Sides Of Foundation Etc. Complete For All Lift. |
| 28 | Providing Surface Marking Sports Ground Area |
| 29 | Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil. |
| 30 | Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) |
| 31 | Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: 6.1.2 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) |
| 32 | 12 Mm Cement Plaster: 1:6 (1 Cement: 6 Fine Sand) Inner Plaster |
| 33 | Providing and fixing factory made precast RCC perforated drain covers,having concrete of strength not less than M-25, of size 1000 x 450x50mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectionalT.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 34 | INTERNAL ELECTRIC WORKS |
| 35 | Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. |
| 36 | Group B |
| 37 | Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. |
| 38 | Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. |
| 39 | 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire |
| 40 | 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire |
| 41 | Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 1.24 |
| 42 | 5/6 A Switch |
| 43 | 3 Pin 5/6 A Socket Outlet |
| 44 | Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required. |
| 45 | Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. |
| 46 | Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connections Etc. As Required. |
| 47 | Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. |
| 48 | Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. |
| 49 | 20 Mm |
| 50 | Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube/Lamp Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. |
| 51 | Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. |
| 52 | Upto 450 Mm Sweep |
| 53 | Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes. |
| 54 | Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, \\"C\\" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. |
| 55 | Single Pole |
| 56 | Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. |
| 57 | Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator). |
| 58 | 8 Way (4 + 24), Double Door |
| 59 | Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. |
| 60 | Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. |
| 61 | Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. |
| 62 | Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. |
| 63 | Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. |
| 64 | Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. |
| 65 | Above 35 Sq. Mm And Upto 95 Sq. Mm |
| 66 | Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. |
| 67 | 3 X 95 Sq. Mm (38Mm) |
| 68 | Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. |
| 69 | 3.5 C X 70 Sq.Mm Al. Xlpe Arm. |
| 70 | Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. |
| 71 | PLUMBING AND SANITARY WORKS |
| 72 | Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. |
| 73 | 15 Mm Dia Nominal Bore |
| 74 | C.W.S (Per Floor 45To95M) |
| 75 | C.W.S D/N Take |
| 76 | Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore |
| 77 | 15 Mm Nominal Bore (All Floor) |
| 78 | Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 |
| 79 | 15Mm Nominal Bore |
| 80 | Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : |
| 81 | 15 Mm Nominal Bore |
| 82 | 20 Mm Dia Nominal Bore |
| 83 | Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) |
| 84 | 20 Mm Dia Nominal Bore |
| 85 | 25 Mm Dia Nominal Bore |
| 86 | Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : |
| 87 | 65Mm Nominal Bore (Horizontal) |
| 88 | Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. |
| 89 | Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 17.3.1 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid |
| 90 | Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. |
| 91 | Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : 17.4.1 One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern |
| 92 | Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wallswherever Require: 17.7.8 White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers |
| 93 | Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour. Waste Coupling 38 Mm Dia Of 83 Mm Length And 77Mm Breadth, Weighing Not Less Than 60 Gms (Sink+ W.B) |
| 94 | Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia (Sink+W.B) |
| 95 | Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. |
| 96 | Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. |
| 97 | Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : Sand Cast Iron S&S As Per Is: 1729 |
| 98 | 100 Mm Inlet And 100 Mm Outlet |
| 99 | 100 Mm Inlet And 75 Mm Outlet |
| 100 | Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing |
| 101 | Providing And Fixing Collar : Sand Cast Iron S&S As Per Is - 1729 |
| 102 | 100 Mm |
| 103 | Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. |
| 104 | Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215Mm Long, 200Mm Nos. Wide With A Minimum Distances Of 37Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colours Weighing Not Less Than 80 Gms |
| 105 | Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design |
| 106 | Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 100 Mm Diameter |
| 107 | Ro Water Atm |
| 108 | TOILET BLOCK & PAVILION |
| 109 | DISMANTLING WORK |
| 110 | OLD BRICK WORK |
| 111 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 112 | DISMANTLING DOOR/WINDOWS |
| 113 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres Of area beyond 3 sq. metres |
| 114 | DISPOSAL OF MATERIAL |
| 115 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 116 | DISMANTLING OF PLASTER |
| 117 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 118 | NEW BRICK WORK |
| 119 | HALF BRICK WORK |
| 120 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 121 | DOOR WORK |
| 122 | DOOR SHUTTER |
| 123 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 124 | SLIDING DOOR BOLTS |
| 125 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc |
| 126 | 300x16 mm |
| 127 | 250x16 mm |
| 128 | HANDLES |
| 129 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. 125 MM |
| 130 | TOWER BOLTS |
| 131 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. |
| 132 | 250x10 mm |
| 133 | 150X10 MM |
| 134 | DOOR STOPPER |
| 135 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper |
| 136 | CASEMENT |
| 137 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 300 mm weighing not less than 330 grams |
| 138 | DOOR FRAME |
| 139 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 140 | NEW FLOORING |
| 141 | ROOMS FLOORING |
| 142 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 143 | ROOMS SKIRTING |
| 144 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm |
| 145 | TOILET FLOOR TILE |
| 146 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 147 | TOILET WALL TILE |
| 148 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 149 | PLASTER & FINISHING |
| 150 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 151 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.. |
| 152 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 153 | WINDOWS |
| 154 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment)Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) . |
| 155 | GRILL |
| 156 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 157 | R.R RETAINING WALL |
| 158 | RETAINING WALL WORK |
| 159 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 160 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Earth filling (For marshy soil) |
| 161 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 162 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 163 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 164 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). kg |
| 165 | STAIRCASE |
| 166 | EARTH WORK |
| 167 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 168 | FILLING IN FOUNDATION |
| 169 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 170 | SOIL TREATMENT |
| 171 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 172 | P.C.C |
| 173 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 174 | REINFORCED CEMENT CONCRETE |
| 175 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). |
| 176 | All works upto plinth level |
| 177 | All works above plinth level upto floor V level |
| 178 | STEEL |
| 179 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars |
| 180 | CENTRING & SHUTTRING |
| 181 | Centering and shuttering including strutting, propping etc. and removal ofform for : |
| 182 | Foundations, footings, bases of columns, etc. for mass concrete |
| 183 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 184 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 185 | Suspended floors, roofs, landings, balconies and access platform |
| 186 | PLASTER & FINISHING |
| 187 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 188 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 189 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.. |
| 190 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer |
| 191 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). kg Please Enable Macros to View BoQ information |