| 1 | Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith Polycarbonate enclosure having more than 200 No's Low Power LED's having minimum power consumption 15 watts complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . aviation obstruction LED light luminaire Min. 15 Watts |
| 2 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . 50 mm dia. |
| 3 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 50 mm OD 4 kg/ cm2 |
| 4 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 5 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 50.0Sq mm 3.5 core |
| 6 | 120 Sq mmm 3.5 core |
| 7 | Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt(d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .17.2 mm thick and 3 Mtr. Long |
| 8 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Red/yellow/Green colour |
| 9 | Blue / white Colour |
| 10 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 11 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.Upto 160 Amp , 50 kA |
| 12 | SITC of IP-43 surface mounting heavy duty modular Sub main Distribution board (SMDB) fabricated by switchgear OEM having short circuit withstand current 35 kA (upto 400 amp.Incomer ) and 50 kA for 630 amp. Incomer with suitable bottom cabling box, 4 no. corner boxes, 2 no. side cabling boxes, metering Extension box with provision of incomer suitable for 3 pole MCCB and 3 pole MCCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.6 mm thick conforming to IEC 61439 Part 1 & 2. , U imp 8 KV, form of separation 2b, powder painted complete with insulated suitable rating tinned copper bus bar, neutral bars with shrouds, earth bar , din bar, making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. (Without MCCB, ammeter, voltmeter, selector switch , Indicating lamp) OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .SMDB with 400 Amp. Incoming and 4 no. 100 Amps Outgoing |
| 13 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 14 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 15 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 16 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Hot rolled deformed bars (IS : 1139). |
| 17 | Supply of 30 meter high mast shaft in three sections suitable for withstanding wind pressure of 47meter/sec with head frame, luminary carriage suitable for installation up to 24 Nos luminaries in asymmetrical arrangement, lighting finial, along with supply of accessories required such as double drum winch, min. 6.0 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box etc – The price shall cover for design and supply of 30 meter high mast for 24 Nos. LED flood light luminaries of 1000 Watt complete with lantern carriage ring, mounting brackets, foundation bolts, templates, winch wire ropes, power tools, etc including connection required for fixing of the above fixture on the high mast. The high mast of 30 meter height should be in three sections, hot dip galvanized and suitable for wind velocity as per IS: 875 (Part 3) 1987 as per latest amendments. It shall also include accessories for high mast including head frame two/three point suspension system with steel wire rope of min. 6 mm diameter (7/19 construction), double drum winch, galvanized lantern carriage arrangement, suitable for 24 Nos of LED luminaries for 30 meter high mast and its control gear boxes and lightning finial. Technical Data Sheet for 30 Meter High Mast and Accessories is given in technical specification of tender document. |
| 18 | supply of marider unit (suitable to carry 300 KG ) Along with its Accessories hardware & antifal arrestor etc.(1 no. for 4 nos. Stadium Mast ) |
| 19 | Transportation Of High mast Pole/Shaft including Loading & unloading at site with all Required Tool And Tackles |
| 20 | Supply, erection, testing and commissioning of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template - The price shall cover for supply, erection, testing and commissioning of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template as per the details given in technical specification of tender document or as per OEM's design |
| 21 | Erection and commissioning of high mast with all required tools and tackles- The price shall cover for erection and commissioning of high mast with all required tools and tackles. The tenderer must see the site closely before quoting the rates with regard to the nature of soil, average depth of decomposed garbage and debris at mast locations and other site conditions before working out the type foundation and specifications for the proposed high mast of Tender schedule. The tenderer shall be responsible for the design of the foundation and safe erection and installation of the high mast in mechanically and structurally safe working condition for the design life of the mast. The load bearing capacity of the soil of site should be taken in to account to decide the type of foundation and itsspecifications, as recommended by the manufacturer. The holding down bolts shall be as per the size and quantity as per OEM's design of high tensile strength (TOR steel, 410 Mpa Y.S.) and shall be supplied complete with anchor plate of required thickness for casting into the foundation. The precision made steel template with tube holes should be provided to ensure correct verticality and horizontally of bolt alignment. Two earth terminals shall be provided for each mast and shall be connected to earth. FENCING - Supply and fixing of hexagonal type M.S. grill fencing is within contractors' scope of work. The rate shall also include painting with primer work of shade and quality as approved by Engineer Incharge Bikaner or site engineer. The paint shall be of Asian/Nerolac/Berger or equivalent make. The rate also includes providing RCC foundation in the ratio 1:2:4 (cement: concrete: sand) or as per manufacturer's recommendations for erection, grouting etc. |
| 22 | Supply, erection, testing and commissioning of 1000 Watt LED flood light fixture specially design for stadium lighting - The price shall cover for supply of energy efficient LED flood light luminary, 1000 Watt capacity with surge protection device 10 kV, PF>0.90, minimum lifetime of 50K Hours @ L70 having pressure die cast aluminium housing, toughened front glass cover, fitted with secondary optics, heat sink and integrated electronic driver for long life with IP 65 protection class for provision on high masts. The fitting shall operate on 240 Volt, 50 Hz AC supply. The luminary shall be suitable for installation on High Mast for stadium lighting application. The price shall also cover for fixing, testing and commissioning of the above flood light luminary on high mast by fabrication and supply of M.S. clamps made from M.S. flat of suitable size, duly painted & with nut, bolts and washers of 12 mm diameter. The connection shall be carried out through ISI marked, PVC insulated, flexible three-core copper wire of size 24/0.20 mm from the existing overhead line/catenary/junction box as per site conditions. The connection cord shall be protected by suitablesize of heavy duty steel wire reinforced flexible PVC conduit of suitable size. The successful tenderer shall submit the lighting scheme with ground illumination chart showing illumination level at cricket pitch and at various zones in field designed through software of OEM (LED Luminaries) firm of LED luminaries for approval. Minimum warranty on LED luminaries shall be 5 years from date of commissioning. Please Enable Macros to View BoQ information |