| 1 | Supply & delivery of 6 Mt. long GI pipe pole assembled with 80 mm dia 3 Mt. long G.I. pipe, 50 mm dia 3 Mt. long G.I. pipe (ISI-Medium - Jindal/Bansal/Tata), 80 mm long 80/50 mm dia GI reducer with outer dia 100/70 mm, MS base plate (200 mm x 200 mm x 6 mm thick) with suitable pole cap as per direction of EIC. |
| 2 | Erection of 6 Mtr. long GI pipe Pole with sole plate & cap etc. in CC foundation (Size - 600 mm x 600 mm x 15 cm), having 600 mm x 600 mm x 150 mm thick CC (4:2:1) base block below sole plate with hard jhama metal including CC (6:3:1) muffing 300 mm dia and 300 mm above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole up to 1.6 Km from Store to Work-Site including filling up the excavated earth pit with shifted soil and ramming properly. [1/ H-1] |
| 3 | Providing CC (6:3:1) base block (around the pole), dimension 45 cm x 45 cm x 60 cm above ground level, neatly cemented finish (3 mm thick), at the base of the pole, incl. drilled holes in the pole suitable for street light wiring. [3(b)(ii)/H-1] |
| 4 | S&F of 32 mm dia, 3 mm thick Polythene Pipe inside the pole, muffing for cable entry from UG to Loop box on Pole through GI Pipe, including supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipe. [1(d)/E-2] |
| 5 | S & F of Steel waterproof-type looping cable box (200 mm x 150 mm x 100 mm deep), having 1.22 mm (18 SWG) thick, comprising 240 V, 16 A kit kat fuse unit, 4 nos. 16 A stud type connectors, lined with rubber gasket Steel top cover with a mechanical locking arrangement, earthing terminal with lug, etc., on a pole above the muffing with S&F 2 nos. flat MS clamp sets made with 25mm x 3mm thick flat iron bar with nut-bolt etc., suitable for fixing on the pole. |
| 6 | Supplying and Fixing of GI water proof looping cable box having hinged GI Top Cover having 2 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, comprising of one 240 V, 16 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing or pillar after dismantling the damaged looping cable box etc. where necy. incl. painting. |
| 7 | 200 mm x 150 mm x 100 mm [16(a)/I-2] |
| 8 | 250 mm x 250 mm x 100 mm [16(b)/I-2] |
| 9 | S & F of 1 meter long, 35 mm x 35 mm x 5 mm thick, MS angle iron on the top of the GI pole with 35 mm x 5 mm thick MS flat iron on half round clamp by a nut-bolt arrangement for fixing 02 nos. LED flood light after making the necessary drilled holes to the required size. |
| 10 | Excavation of soil for the installation of Earth Electrode with filling & ramming for soft soil. [1(a)/G-1] |
| 11 | Earthing with 50 mm dia GI pipe (ISI Medium), 3.64 mm thick x 3.04 Mt. long and 1 x 4 SWG GI (Hot-Dip) wire (4 Mt. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mt. long) to be filled with bitumen partly under the ground level and partly above ground level, driven to an average depth of 3.65 Mts. below the ground level. [2(a)/G-1] |
| 12 | Supplying & drawing of 1.1 KV. Gr. 3 core 1.5 sq. mm PVC insulated Cu. conductor cable (Make - Finolex / Polycab /Havells) from Pole Loop Box to LED fittings. |
| 13 | S&F of 240 V, LED Flood Light fitting (Make- Crompton, Cat No. LFLN-200-CDL/60-M or Similar type of Philips/Wipro). [NS] |
| 14 | S&F of 240V, LED Flood Light fitting (Make - Crompton, Cat No. TFS-504-120-57-60D-HL2-GL-NBK or Similar type of Philips/Wipro). [NS] |
| 15 | Painting of Steel Tubular Pole (up to 9 Mtr. long) with ARM bracket by two coats of aluminium paint over the first coat of RO priming with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning, etc., for receiving a fresh coat of paint. [4(a)/H-2] |
| 16 | Painting of any steel/ iron surface with 03 nos. of coats of paint as one coat of red lead/Zinc chromate priming, 1st coat of synthetic enamel paint over the primer, 2nd coat of synthetic enamel paint over the 1st coat with ready mixed paint/primer (Make: Asian Paints/Deluxe/Barger) incl. preparation of surface by sandpaper/emery paper, cleaning etc. for receiving fresh coat of paint. [7.B(c,d&e)/H-2] |
| 17 | Supply and delivery of the following sizes, 1.1 kV Gr. 2/4 Core XLPE insulated & sheathed Armoured Aluminium Conductor Cable (Make - Havells / Gloster / RR Kabel / KEI). |
| 18 | 2 core 6 sq. mm |
| 19 | 2 core 10 sq. mm |
| 20 | 4 core 10 sq. mm |
| 21 | Supplying & fixing of the following sizes medium gauge GI Pipe (ISI-Medium) protection with necessary fittings and jointing materials as required - |
| 22 | 25 mm diameter [11(C)/F-6] |
| 23 | 32 mm diameter [11(C)/F-6] |
| 24 | 40 mm diameter [11(C)/F-6] |
| 25 | Boring (Micro Tunnelling) below the Pacca/Concrete Road with necessary tools & tackles for installation of 40 mm dia GI pipe, including filling the vacant space between pipe and road with soil, mending the damages as per direction of EIC. |
| 26 | Charges for cutting of Pitch Road (150 mm wide and 300 mm depth) for installation of 40 mm dia GI Pipe and mending the damages to the original finish, incl. removing the rubbish. |
| 27 | Laying of 2 core 6 sq. mm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting. [2(a)/F-1] |
| 28 | Laying of 2/4 core cable up to 25 sq. mm on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting. [2(b)/F-1] |
| 29 | Laying of 2/4 core 6/10/16 sq. mm cables after cutting floor/pavement/wall and making holes, including embedding the cable at an average depth of 75 mm in floor/pavement/wall and mending the damages to the original finish incl. removing the rubbish. [5(i)/F-3] |
| 30 | Laying of one no. 2/4 core 6/10 sq. mm cable in the underground trench of 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per metre, including filling the space between the bricks and cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. [1(a)/F-2] |
| 31 | Laying of 2/4 core 6/10/16 sq. mm cable through existing GI/Polythene Pipe. [3(a)/F-1] |
| 32 | Fixing of 2/4 core 6/10 sq. mm cable along the length of O.H. pole incl. S & F MS pole clamps fabricated from 25 mm x 6 mm MS flat, incl. painting. [F-1/4) |
| 33 | S & F of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of the following XLPE/PVC armoured cables as below: |
| 34 | 2 core 6 sq. mm [7(a)/F-4] |
| 35 | 2 core 10 sq. mm [7(a)/F-4] |
| 36 | 4 core 10 sq. mm [7(c)/F-4] |
| 37 | Finishing the end of the following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: |
| 38 | 2 core 6 sq. mm cable [8(b)(ii)/F-5] |
| 39 | 2 core 10 sq. mm cable [8(b)(iii)/F-5] |
| 40 | 4 core 10 sq. mm cable [8(b)(xii)/F-5] |
| 41 | Supplying and fixing 415 V, 315/320 A TPN SFU with sheet-steel enclosure on an angle-iron frame on the wall, with nuts, bolts, etc., incl. S & F 3 nos. DIN type HRC fuse as per rating (Make - L&K). [4(a)/D-3] |
| 42 | Supply & fixing of 240 V, 25 A, Modular-type starter (Brand approved by EIC) with 25 A Modular switch-type DP MCB (C-Curve) and 4 Module GI Modular-type switchboard with 4 Module top cover plate flush in wall, incl. S&F switch board and cover plate, and making necy. connections with PVC Cu wire and earth continuity wire, etc. (E-19, 17) |
| 43 | Supply & Fixing 240 V, 25 A, 3-pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necessary connections with PVC Cu wire and earth continuity wire, etc. (E-17, 4,c) |
| 44 | Supplying and fixing 240 V, 32 A, DP, MCB type Isolator (Make-Legrand) on din rail of the existing DB and necessary connection. |
| 45 | Supply & Fixing of 65 mm dia and 760 cm long, ISI-Medium GI pipe at the top of the CC pillar, including making a hole in the top centre of the pillar by cement concrete, for the post top LED fittings. Please Enable Macros to View BoQ information |