| 1 | Supply, Installation, Testing & Commissioning of Standrad 4 Mtr(Above Ground) hot dip galvanized(Granding of Galvanisation average 70 micron or better as per IS2629(AOR)Make- Bajaj, Valmont, Transrail |
| 2 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top of suitable size of as directed by the Engineer-Incharge, complete in all respects the armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS.No. 501 Make- Grandlay, Havells,Dicab,Polycab,Gloster |
| 3 | a)- 16 sq. mm x 4 core |
| 4 | b) 50 Sq.mm. 3.5 Core |
| 5 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 |
| 6 | a) 16 sq mm |
| 7 | b) 50 Sq.mm. |
| 8 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 and above Protection complete in all respect. Uppwd-1423 CAT-AAA Make- Havells,LT, Bajaj, Philips, Neri |
| 9 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, ouplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.(a)63 mm dia (OD-63 mm & ID-51 mm nominal)D.S.R 14.16.1 Pg No-49 |
| 10 | S/F following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fusese, isolating switch metering instrument & instrument box with CTs etc.in case of TPN complete in all respects. a) 40 A TPN PS No-807 (F) |
| 11 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Complete in all respect as per direction of E/I. UPPWD-2018 PS - 725B |
| 12 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.DSR-2018 Item No.14.6 |
| 13 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 14 | Numbering of poles with combination of yelow and black colour paint etc. complete in all respects as per direction of E/I (AOR) |
| 15 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.P.S. No. 716 |
| 16 | S/F of Copper Cable 2.5 sq.mm x 3 core Complete in all respects as per AOR |
| 17 | Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I. (AOR) |
| 18 | Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR) |
| 19 | Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR) Please Enable Macros to View BoQ information |