| 1 | PUNJAB WATER RESOURCES DEPARTMENT Madhopur Division UBDC Gurdaspur NAME OF WORK: Estimate for Laying of UPVC pipeline off taking at 62660-L of Fatehnangal Dist, 44500 L Fatehangal Disty and 16900 R of Kunjar Disty. Name of Firm Sr.No Description Unit QUANTITY Rate (in figures) Rate (in Words) |
| 2 | Excavation by mechanical means(JCB or Hydraulic excavator) intrenches for pipe lines with straight or open cutting in streets oropen area including trimming and dressing sides levelling of beds oftrenches to correct grade, cutting joint holes, refillingconsolidation,watering , including the cost of dewatering of rainwater, diversion for traffic, night signals. providing & fixing cautionboards, crossing over trenches for access to the houses, watching,fencing, etc. and removal of surplus soil out side/inside the towninvolving lead upto 15 meter complete in all respect. Earth work upto1.5 m. Depth for. All classes of soil except rocky |
| 3 | Providing and filling sand grading as per specifications or fine gradearound the various sizes of G.I. pipes in external work |
| 4 | First class burnt brick work laid in cement sand mortar 1:4 infoundation and plinth |
| 5 | 10 mm thick cement plaster with cement mortar 1:4 on side walls |
| 6 | 10 mm thick cement plaster with cement mortar 1:4 on bed & top ofside walls |
| 7 | Providing orange colour safety footrest of minimum 6mm thickplastic encapsulated as per IS:10910 on 12mm dia steel barconfirming to IS: 1786 having minimun cross section as 23mm x25mm and over all minimum length 263mm and width as 165mmwith minimum 112mm space between protruted legs having 2mmtread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to with stand the bend test andchemical resistance test as per specification and havingmanufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design |
| 8 | Providing and fixing of Alfa valve of 180 mm dia complete Includingall tax and charges |
| 9 | Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI markedwith the prior approval of Engineer-in-Charge) along the Trenchesand laying the same in Trenches to correct alignment and gradients,cutting, jointing and testing complete as per specifications 300 mmo/d UPVC pipe of 2.5 Kgf. / sqcm |
| 10 | Providing & fixing 180 mm Dia. Equal Tee (6 kg/cm2 pressure)conforming to IS codes with latest amendments if any at site of workincluding loading, unloading and rehandling if any complete in allrespects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 11 | Providing & fixing 180 mm Dia. Short OR long Bend (90 Degree)(6kg/cm2 pressure) conforming to IS codes with latest amendments ifany at site of work including loading, unloading and rehandling if anycomplete in all respects as per design and P.W.D. specifications andinstructions of engineer in charge. |
| 12 | Providing & fixing 180 mm Dia. Socket (6 kg/cm2 pressure)conforming to IS codes with latest amendments if any at site of workincluding loading, unloading and rehandling if any complete in allrespects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 13 | Providing & fixing 180 mm Tail end point 6kg with M.S./C.I. flange(6kg/cm2 pressure) conforming to IS codes with latest amendments ifany at site of work including loading, unloading and rehandling if anycomplete in all respects as per design and P.W.D. specifications andinstructions of engineer in charge. |
| 14 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) andBronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet,all carriage complete (with the approval of Engineer incharge)(A)Class PN-1 as per ISI (g) 140mm i/d Sluice Valves flanged |
| 15 | Providing & fixing Single air valve ISI Marked as per IS-14845including jointing all carriages complete (d) C.I Single air valveScrewed(Size 50mm) |
| 16 | Providing & fixing 180x50 mm Dia. MS Service saddle (6 kg/cm2pressure) conforming to IS codes with latest amendments if any atsite of work including loading, unloading and rehandling if anycomplete in all respects as per design and P.W.D. specifications and and instructions of engineer in charge. |
| 17 | Providing, laying, fixing, testing and commissioning of Class heavyduty MS Pipe conforming to IndianStandard IS:1239/3589 includingfittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts,gasketsetc. fixing the pipe on the wall /ceiling with suitable clampsandpainting with two or more coats of synthetice paint of required shade complete in all respects. (d)50mm internal diameter |
| 18 | Construction of masonary Sluice Valve Chamber excluding Sluicevalve cover as per standard design & drawings of public healthdepartment. Size 0.6 m. x 0.6 m. |
| 19 | Construction of masonary Sluice Valve Chamber excluding Sluicevalve cover as per standard design & drawings of public healthdepartment. Size 0.9 m. x 0.9 m. |
| 20 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as perIS 1786-2008) , for R.C.C works, where not including in the completerate of RCC including binding, bending and placing in positioncomplete |
| 21 | Shuttering for faces of concrete foundations and foundation beam &plinth beam (vertical or battering) |
| 22 | Reinforced cement concrete M-20 mechanically batch mixed usingbatch type concrete mixer as per IS:1791 and vibrated by needlevibrator but excluding steel reinforcement centring and shuttering infoundation and plinth. |
| 23 | Any other item Compatibility Report for Harpur.xls Run on 28-03-2025 12:10 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Minor loss of fidelity # of occurrences Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 2.0 'boq 1'!B21 'boq 1'!C22 |