| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches, drains not exceeding 1.5 m in width 10sq.m on plan including dressing of sides ramming of bottoms for all lift including getting out the excavated soil & disposal of surplus soil for all lead and in all types of soft stratas comprising any of the materials such as soil, silt, sand, clay, gravel, moorum of all varieties shingles, pebbles all types of conglomerates, laterite rocks, ordinary rocks, soft rock disintergrated rocks, fissured, shuttered/decomposed rock, weathered rocks and all such other materials as described under appendix A to these specification either in full or in parts as the case may be adopting any method / methods as may be convenient or permitted inclusive of chiseling, wedging etc, blasting prohibited and in all conditions such as dry , moist , foul, saturated submerged etc including providing barricading, danger lighting guarding and as per the direction of the Engineer-in-charge etc. |
| 2 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Cast iron double flanged manually operated Sluice Valve, generally conforming to IS:14846 - 2000, having body, door, dome, wedge in graded cast iron to IS:210 Gr. FG 200 min., four faces and spindle nut of leaded tin bronze to IS:318 Gr. LTB 2, inside screw of non-rising stainless steel AISI410, spindle, flanges drilled to IS:1538 Table 4 & 6. Valves tested by closed end method only (350mm and above will be fitted with BTB and Spur gear box and back seat bush.) etc. complete TYPE P.N. 1.6 (Class A ); Dia in mm; 450 |
| 3 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Cast iron double flanged manually operated Sluice Valve, generally conforming to IS:14846 - 2000, having body, door, dome, wedge in graded cast iron to IS:210 Gr. FG 200 min., four faces and spindle nut of leaded tin bronze to IS:318 Gr. LTB 2, inside screw of non-rising stainless steel AISI410, spindle, flanges drilled to IS:1538 Table 4 & 6. Valves tested by closed end method only (350mm and above will be fitted with BTB and Spur gear box and back seat bush.) etc. complete TYPE P.N. 1.6 (Class A ); Dia in mm; 400 |
| 4 | Supplying cast iron fittings as per IS : 1538 -1993 including sealing rubber gasket (NR) CI Compression glands and coated MS Nuts bolts.; Flanged Socket Tail piece ( Flanged Adaptors); Nominal Dia in mm; 450 |
| 5 | Supplying cast iron fittings as per IS : 1538 -1993 including sealing rubber gasket (NR) CI Compression glands and coated MS Nuts bolts.; Flanged Socket Tail piece ( Flanged Adaptors); Nominal Dia in mm; 400 |
| 6 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; M.J.Collar; Nominal Diameter in mm ; 450 |
| 7 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; M.J.Collar; Nominal Diameter in mm ; 400 |
| 8 | Cutting of cast iron / ductile iron pipes by mechanical grinder working on electricity, including the cost of hire charges of mechanical grinder, diesel operated electrical generator set, suitable for supplying power for the grinder for cutting, cost of grinding blades , skilled work force, fuel.etc. required for completion of job as per the direction of Engineer- in -charge; Dia in mm; 450 |
| 9 | Cutting of cast iron / ductile iron pipes by mechanical grinder working on electricity, including the cost of hire charges of mechanical grinder, diesel operated electrical generator set, suitable for supplying power for the grinder for cutting, cost of grinding blades , skilled work force, fuel.etc. required for completion of job as per the direction of Engineer- in -charge; Dia in mm; 400 |
| 10 | Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc. .complete as directed as per IS:2685-1971 CLASS II & III.; Nominal diameter in mm.; 450 |
| 11 | Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc. .complete as directed as per IS:2685-1971 CLASS II & III.; Nominal diameter in mm.; 400 |
| 12 | Making joints to D.I/ C.I pipes with mechanical joints by nut bolts rubber rings that are provided with the joints, forpushon tight joints including the cost of work force, tools, hydraulic testing of joints, etc. complete as per the direction of the engineer in-charge.; Double socketed specials such as bends, collar couplings,etc.; Nominal Diameter in mm ; 450 |
| 13 | Making joints to D.I/ C.I pipes with mechanical joints by nut bolts rubber rings that are provided with the joints, forpushon tight joints including the cost of work force, tools, hydraulic testing of joints, etc. complete as per the direction of the engineer in-charge.; Double socketed specials such as bends, collar couplings,etc.; Nominal Diameter in mm ; 450 |
| 14 | Construction of masonry chamber 120 x 120 x100 cm inside in laterite masonry in neatly dressed stones complete with 23 cms wall thickness and in cement mortar 1:4 ( 1 cement : 4 coarse sand) for sluice valve size beyond 200mm dia with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing. (rate is inclusive of rate earthwork excavation, cost of surface-cover and all other materials and labour and as per details below); with M.S. sheet cover with 6 mm thick M.S. plate and frame of angle iron 50x50x6mm in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size) |
| 15 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. Please Enable Macros to View BoQ information |