| 1 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 3 | Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 |
| 4 | Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 |
| 5 | Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. (Gloster/Universal/Polycab/ Havells/Diacab/KEI make) . (AOR) |
| 6 | Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. Size 185 Sq.mm. 3 Core (AOR) (Gloster/Universal/Polycab/ Havells/Diacab/KEI make) |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. .(DSR elect 2018 Item.N. 8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. (DSR elect 2018 Item.N. 8.4.2/P31) Above 120 Sqmm and upto 400 Sqmm |
| 9 | Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 10 | Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required. (DSR elect 2018 Item.N. 8.8.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 11 | S/F of jointing of 300 sq. mm out door End Termination for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson/ Capseal as per direction of E/I. (UPERC P-47) |
| 12 | S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. (UPERC P-47) |
| 13 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat End Termination Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) Size 185 Sqmm uperc Pg-29 |
| 14 | S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS & complete as per the direction and satisfaction of E/I (Raychem, Denson, Cabseal Make) UPERC 2019 Pg-29 |
| 15 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.10.5.3 (a) 240 sqm |
| 16 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core x 240 sq.mm XLPE aluminium conductor cable of 11 KV grade as required : DSR 2018 I.no-10.6.3 |
| 17 | S/F of 6\\" dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) |
| 18 | S/E of over head line with ACSR Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 |
| 19 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) PS No. 725(A) |
| 20 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing. PS No. 725 (B) |
| 21 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. PS No. 716 |
| 22 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. DSR 2018 13.4 |
| 23 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC Pg-39 |
| 24 | S/F of 11 KV Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on HT Pole UPERC P-43 |
| 25 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018/I.No. 13.23 |
| 26 | Supply & fixing of 33 KV with 11KV 4 Nos Set B&S type strain Disc insulators 120KN E&M strength. as per drawing complete in all respects as per direction of E/I.(AOR) |
| 27 | S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects as per direction of E/I (UPERC 2019) |
| 28 | Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 |
| 29 | Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) |
| 30 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 |
| 31 | S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 |
| 32 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer) (AOR) |
| 33 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 (Make-Havells/Grandley/Polycab/ Diatron/Gloster/Kalinga). 16 sqmm x 4 core |
| 34 | 50 sqmm x 3.5 core |
| 35 | 70 sqmm x 3.5 core |
| 36 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 16 sqmm |
| 37 | 50 sqmm |
| 38 | 70 sqmm |
| 39 | 185 Sqmm |
| 40 | 300 Sqmm |
| 41 | S/F of 11 kv, 100 Amp, Drop Fuse set Channel type 3 nos. (AOR) |
| 42 | S/F of 11 kv TPMO 9 nos insulator. complete in all respects. UPERC P no- 48 I No. 13 |
| 43 | Dis/Re-fixing of 63/100 kva transformer with connection loading & unloading, cartage charge from site to repairing at worshop complete in all respects as per direction of E/I (AOR) |
| 44 | Supply and laying 90 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 45 | Supply and laying 120 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 46 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required DSR 2018 12.38 |
| 47 | Supplying and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete asrequired.DSR 18 14.16.1 (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer) 63 mm dia ( OD-63 mm & ID 51 mm nominal) |
| 48 | 90 mm dia ( OD-90 mm & ID 76 mm nominal) |
| 49 | Supply and Laying of copper cable 2.5 sqm x 3 core. Complete in all respect as per direction of engineer in-charge(AOR) |
| 50 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respect. PS No-807 (f) 40 A TPN |
| 51 | Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100mm, Bottom dia 200 mm and base plate 16mm thik) having 3 mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect as per direction of E/I. PS No 649 |
| 52 | Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100 mm, Bottom dia 200 mm and base plate 16mm thick) having 3 mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P complete in all respect as per direction of E/I. PS No 650 |
| 53 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. . PS No. 1424 Cat AAA |
| 54 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR Electrical 2018/ I. No. 12.42 |
| 55 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. DSR Elect 2018/I-12.40 |
| 56 | Providing and laying of MS Pipe of 200mm dia 6mm thickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) |
| 57 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N. 7.9/P30) |
| 58 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing, of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil, Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (AOR) |
| 59 | Demolisihing cement concrete manually/ by mechanical means including disposal of material within 50 maters lead as per direction of Engineer- in- charge Nominal concrete 1.3.6 or richer mix (i/c equivalent design mix) (AOR) |
| 60 | Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas exceeding 30 cm in depth, 1.5 m, in width as well as 10 sqm on plan) including getting out and disposal of excvated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.(AOR) |
| 61 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer if filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer-in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer-in-charge. (Civil AOR) P-20 |
| 62 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing, in position and binding all complete upto plinth level. Cold twisted bars (AOR) |
| 63 | Supply and fixing of 4 no of M24x750mm long 'J' type EN 8 grade foundation bolts along with templete suitable for 9 mtr. 10 mtr. 11 mtr. 12 mtr. Octagonal poles. (AOR) P-39 |
| 64 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all mlaterials, labour, tools & plants etc. required for proper completion of the work. SOR 5.07 Schedule Item no. 279 (a) |
| 65 | Concrete with 4 cm gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 8:4:1 in foundations and under floors including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. SOR 5.04 Schedule Item no. 275 |
| 66 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) |
| 67 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion.(AOR) |
| 68 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns (AOR) |
| 69 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.DSR Civil, I.No. 5.9.2 |
| 70 | Hire Charges of Mobile Hydraulic Crane 35 tonne Capacity (173HP) (Based on DAR-2018 & Latest Material/Labour Rate of (AOR) |
| 71 | Earth work in Embankment in ordinary soil embankment to be in 20cm layers including ramming. Dressing the surface to required levels with half tonne steel or wooden rammer and rolling every third and top most layer in roller 8 to 10 tonne capacity and including 1.50mtr., Lift and all lead (earth shall be brought from a place wich includkong cartage of earth by mechanically transport and T & P. Labour etc. required for proper completion. Earth shall be arranged by the contractor at his own cost. (AOR) |
| 72 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on Drains of footpath of various sizes, if M-25 grade cement conceoto for RCC work, including cost of centering , shuttering reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways, neat cement punning on finished surface, property encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc I/E cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-charge.(DSR CIVIL) 16.93 (AOR) |
| 73 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR Civil/I.No. 5.2.2 |
| 74 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. required .(AOR) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (AOR) Please Enable Macros to View BoQ information |