Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BOQ-AS/E of Terminal Gantry Structure of R.S. Joist - 175x85 mm. 19.5 Kg/Mtr. 6.1 Mtr. above the ground and 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. with 2 nos channel 175x85 mm suitable for Disc & Pin Insulator Including earth excavation back filling making plinth of required height and with required fabrication as per drawing. complete in all respects as per direction of E/I.(AOR) |
| 2 | S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama/UPPCL approved. as per direction of the E/I. (AOR) |
| 3 | Supply, Errection, Testing & Commissioning of 33 KV Outdoor VCB with required str, 1250A, 1500MVA, 25KA, Motorized 750MVA/1250Amp/ with transformer control & relay pannel including CT, PT with structure. complete in all respects Make: Crompton/ABB/Schneider as per specification and direction of E/I. (AOR) |
| 4 | S/E of Busbar Gantry Structure of 105 Lbs/Yard Rail pole 6.50 M long 5.2 Mtr. above the ground level and 1.30 Mtr. Below in 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. With M.S. angle 100x100x8mm (12.1Kg/M) mm suitable for Disc insulator including earth excavation, back filling, making plinth of required height and with required fabrication as per drawing complete in all respects as per direction of E/I.(AOR) |
| 5 | S/E of 33 KV, 1250A Bus Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. Thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/M and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects Make: Jaipuria/Rama as per direction of the E/I. (AOR) |
| 6 | S/F of 33 KV fuse set out door type of Relco/Rama make complete including structure as per drawing. Complete in all respects.(AOR) |
| 7 | S/E of 33 KV Lightning Arrestors with Structure made of M.S. Channel 125x65 mm. 13.1Kg/M top of M.S. Angle 50x50x6 mm. 4.5 Kg/M Lightning Arrestors/Post Insulator are to be mounted on M.S. Plate of 200x150x8 mm. Height of structure is to be 3.5 Mtr. above ground and 1 Mtr. below ground on a 75 mm. thick cement concrete pad with 1:4:8 cement concrete foundation, making plinth of required height including all fabrication as per drawing complete in all respects Make: Elpro/Oblum/ W/S as per direction of E/I. (AOR) |
| 8 | Supply & fixing of 33 KV with 11KV 4 Nos Set B&S type strain Disc insulators 120KN E&M strength. as per drawing complete in all respects Make : Jaishree/BHEL/WS/RR as per direction of E/I.(AOR) |
| 9 | Supply & fixing of 33 KV tension fitting suitable for panther conductor and 120KN E&M 11KV disc insulator set of 4 complete in all respects as per direction of E/I. (AOR) |
| 10 | Construction of 33 KV transformer plinth as per drawing. with all material, labour and T&P etc. required for proper completion of the work as per specifications of UPPCL as per direction of E/I.(AOR) |
| 11 | Providing and fixing of G.I. Chain Link fabric fencing of required width size50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required Complete as per the direction of Engineer-in-charge. Made of G.I. Wire of dia 4mm PVC Coated to achieve outer dia not less 5mm in required colour and shade. Complete in all respect as per direction of E/I.(AOR) |
| 12 | Construction of boundary wall in brick work with cement mortar 1:6 (1 Cement : 6 Coarse Sand) for chain link including plaster in cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finishing with water proofing cement paint complete as per attached drawing & complete in all respects as per direction of E/I.(AOR) |
| 13 | S/Fixing of 33 KV Post insulator 2x22KV of approved quality and make with all necessary material required for proper fixing including structure made of 125x65mm MS Channel (2.5Mtr above ground of 1 mtr below with ground with grouting 1:3:6 cement concrete including all labour, material, T&P etc. required for proper completion of the work. as per drawing. complete in all respects Make: Jai shree / BHEL as per direction of E/I (AOR) |
| 14 | 1 nos 1250 A VCB of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed, air insulated metal clad housing floor mounting horizontal isolation, vermin proof. Fully interlocked horizontal draqout type having isolation features and control devices complete with following 8 nos single phase double core current transformer 300/5, 5/5 Amp epoxy cast resin isulated class of isulation E as per SLD. Core 1-15 VA burden class 1.0 for metering Core 2-15 VA burden class 5P10 for protection One no. numerical microprossor based three phase over current (IDMT element) with earth fault relay with instantaeous elements 1 no Anti Pumping device 1 no Circuit breaker control switch for eletrical (T/N/C) 1 No. limit switch for test & service 1 no Ammeter (0-300AMP & 0-5 Amp) with selector switch. (96 mm square). 1 No Electronic type digital energy analyser having 30 days memory and parameters of KW KWH, Power factor, frequency etc Suitable for BMS compatible with all accessories. 1 No Tri vector meter, 1 set of following indicating lamps, Red, Yellow & blue for phase indication, Amber for trip indication, Red \\"On\\" Green \\"Off\\", Spring charge indiacation, Auto trip Indication, 1 No Hooter with hooter acceptance and reset push button. 1 No master trip relay. ( Eletromechanical type), 1 set of fuses ferrules wiring etc as required. Note : All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate terrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5 sqmm subjected to providing minimum size suitable for 4/6 sqmm, Incommer & Buscoupler shall be electrically interlocked.11 KV H.T. Panel should have 02 Nos Incomer, 01 No. Buscoupler & 8 Nos Outgoing panel as per approved by specification of UPPCL describe as above (Make-ABB, Schiender, CG Power, Seimens) |
| 15 | Construction of control cable trench of required size 0.30x0.45 Mtr. bricks class designated-100 work including plastering etc. and covered with R.C.C. Slab (0.50x0.60 M) size complete with all material, labour and T&P etc. required for proper completion of work. complete in all respects. As per direction of E/I.(AOR) |
| 16 | S/Filling of 20 mm. stone grit in yard of size26x36mtr 75 mm. thick complete in all respects. (AOR) |
| 17 | S/F of 6\\" dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) |
| 18 | Supply & laying of earth mat in the switch yard of the Sub-Station for all Electrical Equipments and structure by laying of M.S. Round bar of 32 mm. dia. in 750 mm. deep trenches and earth electrode 3.0 M. long of M.S. round bar 32 mm. dia 0.5 M below ground level. The work include welding/bending/flooring of M.S. round bar and connection all steel structure in switch yard with earth mat by means of M.S. Strip of size 50x6 mm. including all labour, materials, T&P etc. required for proper completion of the work as per details specification of UPPCL Complete in all respects as per direction of E/I. (AOR) |
| 19 | Painting of (Complete sub-station) Terminal Gantry, Lighting arrestor, Busbar Gantry, Line Isolator & Bus Isolator Structures, Post insulator, Fencing, Poles and other structure complete with two coats of Al. paint over red oxide. (AOR) |
| 20 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) |
| 21 | Supply and laying of Control Cable for metering as per direction of E/I. (Gloster/Universal/Polycab/Havells/Diacab/KEI make) (AOR) (a) 2.5 Sq. mm. 2 Core Copper |
| 22 | (b) 2.5 Sq. mm. 4 Core Copper |
| 23 | (c) 2.5 Sq. mm. 10 Core Copper |
| 24 | Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-48 |
| 25 | S/E of 125x65 mm. MS Channel (13.10 Kg/M) 1.5 M long fixing in control room for OCB/VCB pannel complete in all respects as per direction of E/I.(AOR) |
| 26 | Supply/Fixing of MS ladder of size 5 mtr long and 0.4m width with MS angle 40x40x6mm incl painting etc . complete in all respect as per direction of E/I.(AOR) |
| 27 | Supply, Installation, Commissioning & Testing of Battery charger 24V 24V/40Amp float cum Boost battery charger with dropping diodes suitable for I/P 230V±10%, 1 Phase, 50Hz Type FCBC as per PVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output current 40A, Plus trickle charging current of battery floatmode 20A(Max), Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10 A upto 2.75 V Per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1% for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration 1-phase full wave controlled, thyristor bridge feed through 1-phase transformer and controlled by constant current/protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protection as per detail specification enclosed. IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload , DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C. Current 230V Input with ANC cooling type and Class F type insulation. For Battery : 240V/200AH Tubular type Battery Bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories (AOR) |
| 28 | S/Installation, testing & commissioning of out door type 10 MVA with on load tap changer Power Transformer as per ISI specification including loading, unloading, local carriage & erection of the same on existing plinth & making all necessary connection etc. Complete in all respects Make: Crompton/ Alstom/BHEL/ABB/Schneider or approved GTP from UPPCL/PVVNL cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side.cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer +/- 7.5@ 2.5% Bi directional roller, Conservator with drain valve, Earthing terminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug, Buchholz relay with shut off valve, Winding temperature indicator (WTI), Oil Temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box (AOR) |
| 29 | S/Laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 75 cm. below ground level over a cushion of 75mm. Below ground level over a cushion of 75mm. thick snad alround and protected with burnt bicks on sides and on top. on surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Gloster/Grandly/Polycab/Daicab/Havell's/KEI make). a) 50 Sq.mm. 3½ Core |
| 30 | b) 25 Sq.mm. 3½ Core |
| 31 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. P.S. No. 1131 |
| 32 | Supply and fixing of Lugs(socket) for Cable P.S. No. 504. i) 25 Sq.mm. |
| 33 | ii) 50 Sq.mm. |
| 34 | iii) 120 sq mm |
| 35 | iv) 185 Sq.mm. |
| 36 | S/F of brass nickle plated compression gland for PVC isulated & armoured served sheathed, underground cable incl. rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of E/I P.S. No 503. (a) Size 25 mmx 3.5 core |
| 37 | (b) Size 16 mmx4 core |
| 38 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) |
| 39 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) |
| 40 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 |
| 41 | S/E of overhead line with ACSR (Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 |
| 42 | S/F of fire bucket, round bottom made of GI sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket, chained & locked initially filled with fine river sand, water as per direction of E/I. P.S. No. 1133 |
| 43 | S/F of shock treatment chart (Prescribed under I.E. Rules) duly framed with glass & supported from back with hard board or soft board with supply of all material labour and T&P for proper completion of work. P.S. No. 1134 |
| 44 | S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. P.S. No. 1136 |
| 45 | Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 |
| 46 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :DSR 2018. 120 Sq.mm.I.No. 10.5.2 |
| 47 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : 120 Sq.mm. UPERC Pg-27 |
| 48 | 185 Sq.mm UPERC Pg-29 |
| 49 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.DSR-2018/Item No. 14.13.2. 80mm dia 14.13.2 |
| 50 | 100mm dia 14.13.3 |
| 51 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 52 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018/I.No. 13.23 |
| 53 | Supply and fixing Clamps, bolts, nuts etc.complete in all respects (DSR-2018/I.No. 2924) |
| 54 | Supply of following type high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. Complete in all respects (Make: Gloster/Polycab/Havells/Diacab/KEI) as per direction of E/I. i) 185 Sq.mm. 3 Core (AOR) |
| 55 | ii) 120 Sq.mm. 3 Core (AOR) |
| 56 | Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 57 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 |
| 58 | S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 |
| 59 | S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I (UPERC 2019) |
| 60 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 61 | BOQ-BSupply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 62 | Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 |
| 63 | Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 |
| 64 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 65 | Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. (Make Gloster/Universal/Polycab/Havells/Diacab/KEI). (AOR) |
| 66 | Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 67 | S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson as per direction of E/I. (UPERC P-47) |
| 68 | S/F of 6\\" dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) |
| 69 | S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. (UPERC P-47) |
| 70 | S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 |
| 71 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) |
| 72 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) |
| 73 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 300 Sqmm |
| 74 | Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 |
| 75 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 |
| 76 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 |
| 77 | S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 |
| 78 | Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) |
| 79 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (Creator poly extrusion/duraline/rex/times/ narander plast/pioneer make). (AOR) |
| 80 | Providing and laying of 200mm dia 6mm thickness through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) |
| 81 | S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama. as per direction of the E/I. (AOR) |
| 82 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N. 7.9/P30) |
| 83 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required..(DSR Electrical 2018/Item 13.23 Page 50) |
| 84 | Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation, ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) |
| 85 | Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturer's specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) |
| 86 | Lettering with black japan paint of approved brand and manufacturer (AOR) |
| 87 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all mlaterials, labour, tools & plants etc. required for proper completion of the work. SOR 5.07 Schedule Item no. 279 (a) |
| 88 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 89 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. (AOR) |
| 90 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion.(AOR) |
| 91 | BOQ-CWiring points for light with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and ceiling rose/angle/batten holder 3mm thick phenolic laminated backelite sheet etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 138C |
| 92 | Wiring points for Fan/fresh air fan (light duty exhaust fan) with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and ceiling rose 3mm thick backelite sheet etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 140C |
| 93 | Wiring points for Plug with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and socket etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 141C |
| 94 | Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. P.S No. 1405 Cat AAA |
| 95 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. PS No. 1002 Cat A |
| 96 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) |
| 97 | Supply and fixing of power plug with 15A / 250 V flush type switch and 5 pin 15 A / 250V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with Bakelite sheet cover 3 mm. thick fixed with brass machine screws and cup washer. P.S. No. 1139 |
| 98 | Supply and wiring of submain with two number 6 sqmm FR PVC insulated 1100V grade multistrand single core copper conductor cable in 25mm dia heavy duty (2mm thick) PVC Conduit/Channel with one number 4 sqmm FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. as per PS No. 212 (C) |
| 99 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No. 641 |
| 100 | fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.CAT- AAA PS No 1423 |
| 101 | S/L of Al. armoured cable PVC insulated served & sheathed cable 1100 V grade at 750 mm ground level protective with brick Complete in all respects as per direction of E/I 25 sq. mm 2 core. (Gloster/Universal/Polycab/Havells/Diatron/KEI make) P.S 501. a. 25 sq. mm 3.5 core |
| 102 | b. 35 sq. mm 3.5 core(PS No. 501(k) |
| 103 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS No 807 E (ii) 25 A TPN |
| 104 | S/F surface/flush mounting 6 ways TPN distribution board without MCB complete in all respects and as directed at site. PS No.1027 Cat A |
| 105 | S/F of hexagonal fan box with hexagonal side of approx. 80mm in lenth fabricated from 16SWG MS Sheet incorporating 10mm dia M S round bar duly duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all materials, labour, T&P etc. for proper completion of work PS No. 1149 |
| 106 | S/F of fan regulator dimmer 250/300W ISI mark on the existing switch board including making connection T&P etc. for proper completion of work to the satisfaction of Engineer of work. PS No. 1203 |
| 107 | S/F of Palm or pin type tin plated copper cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of E/I. (PS No. 504 (e) 25 sq.mm |
| 108 | f) 35 sq. mm |
| 109 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve as per PS No. 1020 (A) |
| 110 | Supply and fixing of following size heavy duty industrial type Exhaust fan with louvered shuttersof approved make complete with wire guard mesh, mounting sings frame bracket etc. but without regulator suitable for use on 230/240V 50Hz single phase AC supply and conforming to IS: 2312-1967 with update amended (900 RPM) (Havells single phase Model-300mm) 300mm dia (AOR) |
| 111 | Supply and Fixing of Ceiling fan 1200 mm dia ISI marked Make-Bajaj, Crompton, Havells or equivalent make. (AOR) |
| 112 | BOQ-DSupply of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of UPERC P-45 |
| 113 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 114 | Supply of Top MS Channel 100x50x2240mm (2.50 Mtr long) as per design complete in all respects UPERC P-39 |
| 115 | Supply of required clamp made of MS Nut, bolt etc. as per direction of E/I complete in all respects UPERC P-39 |
| 116 | Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (Gloster/Universal/Polycab/Havells/Diacab/KEI make)(AOR) i) 185 Sq.mm. 3 Core (AOR) |
| 117 | Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 118 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29. 185 Sq.mm. |
| 119 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE-100 grade as per IS code 4984 with excavation at depth of 1.20 Mtr. Below ground level i/c the cost of cutting of pipes for making upto length and making joints complete all respects asper direction of E/I (Crator Poly extrusion/Duraline/Rex/time/narander plast/Poineer make) (AOR) |
| 120 | Providing and laying of MS Pipe of 200mm dia 6mm thickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) |
| 121 | S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS & complete as per the direction and satisfaction of E/I (Raychem, Denson, Cabseal Make) UPERC 2019 Pg-29 |
| 122 | S/F of 6\\" dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) |
| 123 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. DSR 2018 13.4 |
| 124 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC Pg-39 |
| 125 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 185 Sqmm |
| 126 | Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 |
| 127 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I. (AOR) |
| 128 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 |
| 129 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 |
| 130 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N. 7.9/P30) |
| 131 | S/E of over head line with ACSR Dog Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 |
| 132 | S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 |
| 133 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) |
| 134 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) |
| 135 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all mlaterials, labour, tools & plants etc. required for proper completion of the work. SOR 5.07 Schedule Item no. 279 (a) |
| 136 | Concrete with 4 cm gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 8:4:1 in foundations and under floors including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. SOR 5.04 Schedule Item no. 275 |
| 137 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) |
| 138 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion.(AOR) |
| 139 | Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturer's specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) |
| 140 | Lettering with black japan paint of approved brand and manufacturer (AOR) |
| 141 | Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation, ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) |
| 142 | BOQ-EOperation of 33/11 KV Sub-Station round the clock in 3 shifts of 8 hours each by a team comprising of one electrician, skilled operator (having minimum qualification of ITI (Electrician grade) and one unskilled helper in each shift for operation of S/S equipments including maintenance of 11 KV incoming and outgoing Switchgear panels, 33 KV Switchgear pannels, battery and battery charger, 33/11 KV Transformer with control pannels, HT/LT Cable/Lines along with all associated equipments installed at 33/11 KV Sub-Station compus, (Contractor may deploy required man power, as and when required for attending breakdown within minimum time as detailed in Tech. Specification and distribution code) and maintain the required records as per U.P.P.C.L. (AOR) |
| 143 | 11 KV RMU Panel (3 Way RMU):-Design manufacture testing at works supply, installation testing & commissioning of 3 panel Board 11KV, Indoor tree standing, floor mounting totally enclosed mela clad VCB insulated comprising of 1 Nos 11KV isolater load break switch and 2 Nos Vaccum circuit breaker as outgoing enclosed in robotically laser weided non-extensible type stainless steel SF6 VCB enclosre with Self Powered relay (IDMTL O/C +E/F) as HT switchgear including suitable transformer protection relays, metering, indicators push buttons, copper busbars, etc as per the requirement complete as required The fault with stand capacity shall be minimum 20KA for 1 second including four cable entries for two incoming cable and two outgoning cable glands and lugs suitable for 2x 240/185 sqmm XLPE armoure cable. Incomer shall be provided with 630A Manual Load Bread / Fault Make switch, integral Earthing Switch with making switch, \\"Live Cable\\" Indicating LEDs energized thru Capacitive Voltage Deviders, Transparent Viewing window for verification of Earthing, Right Angle terminal protectors / Boots, Electrical & mechanical indications as required, Outgoing feeders: Two nos. Vaccum circuit breakers with the following |
| 144 | SF-6 insulated 630A Circuit Breaker, integral Earthing Switch with making switch, Emergency Trip Push Button, Electrical & mechanical indications as required, Shunt Trip coil for external trip signal, \\"Live Cable\\" Indicating LEDs energized thru Capacitive Voltage Dididers, Transparent Viewing window for verification of Earthing, Right Angle terminal protectors /Boots, IDMT relay for Circuit Breakers self powered, Merlin Gerin type VIP35 or equivalent with required protection CTs of suitable ratio, Cable box for incoming and outgoing shall be suitable for icrminating, 11KV, XLPE insulated Aluminium conductor armoured cables, One set inbuilt DC power pack , Transformer protection relays as required as per SLD. Complete in all respects (AOR) (Make-ABB, Schiender, CG Power, Seimens) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail