| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. All kinds of soil. |
| 2 | Ordinary rock |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavationfor sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m,including getting out the excavated soil, and then returning the soil as required,in layers not exceeding 20 cm in depth, including consolidating each depositedlayer by ramming, watering, etc. and disposing of surplus excavated soil asdirected, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 4 | Earth work in rough excavation, banking excavated earth in layers not exceeding20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller orwooden or steel rammers, and rolling every 3rd and top-most layer with powerroller of minimum 8 tonnes and dressing up in embankments for roads, floodbanks, marginal banks and guide banks or filling up ground depressions, leadupto 50 m and lift upto 1.5 m : All kinds of soil |
| 5 | Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost ofrequired centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize) |
| 6 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources :64 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 10 | Columns, piers, abutments, pillars, posts and struts |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Suspended floors, roofs, landings, balconies and access platform |
| 13 | Retaining walls, return walls, walls (any thickness) including attached pilasters,buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 14 | Supply and RCC perforated drain cover for both straigth portion M30 grade of size 600x600x60mm with 9mm rode @ 100mm c/c cover the wall of drain at proper level for case flow of water. |
| 15 | Supply and RCC perforated drain cover for both striaght portion M30 grade of size 600x300x60mm with 9mm rode @ 100mm c/c cover the wall of drain at proper level for case flow of water. |
| 16 | Providing and laying of DWC- SN( IS: 16098-11 ) Pipe 300mm dia in under ground system for providion in electrical line and sprinkle lineseleeve purpose and drainage outler completed in all respect as fper direction of engineer in charge. |
| 17 | Excavating, supplying and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth inlayers not exceeding 20 cm in trenches, plinth, sides of foundation etc.complete. |
| 18 | Providing and laying of polypropylene fiber Gertextile separation barrier 140 GSM, as per the standard procedure complete as required. |
| 19 | Construction of granular sub-base by providing close graded Material conformingto specifications, mixing in a mechanical mix plant at OMC, carriage of mixedmaterial by tippers to work site, for all leads & lifts, spreading in uniform layers ofspecified thickness with motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, complete as perspecifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 |
| 20 | Providing, laying, spreading and compacting graded stone aggregate (size range53 mm to 0.075 mm ) to wet mix macadam (WMM) specification includingpremixing the material with water at OMC in for all leads & lifts, laying in uniformlayers with mechanical paverfinisher in sub- base / base course on well preparedsurface and compacting with vibratory roller of 8 to 10 tonne capacity toachievethe desired density, complete as per specifications and directions ofEngineer-in-Charge. |
| 21 | Providing and laying of synthetic artificial football turf of FIFA approved or preffered manufactured/ supplier and to be installed by FIFA/FIH certified field builder. The job includes cutting, fixing and infilling of silica sand for stabization and SBR Granules for performance infill on top as per attain FIFA quality certificate |
| 22 | Supply and installation of movable type football goal post approved by FIFA standard |
| 23 | Construction of Rain water harvesting pit approx. Size 4m lengthx4m width plan area as per design and drawing approved by Engineer-in-charge. |
| 24 | Dry stone pitching ( any thickness ) including cost of stones. On Horizontal. |
| 25 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominalsize). |
| 27 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washersas required complete as per the direction of Engineer-in-charge. |
| 28 | Structural steelworkriveted,boltedorweldedinbuiltupsections, trussesandframed work, including carriage complete job. |
| 29 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | Providing & fixing upto floor five level compressed stabilized earth blocks (CEB)made an appropriate mix of dry inorganic subsoil, non-expansive clay, sand, andaggregate with 5% cement as stabilizer, in mud mortar, including cost of materialscomplete. |
| 32 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately). Second class Kail wood |
| 34 | Providing and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall bepaid separately)Second class kail wood 35 mm thick shutters |
| 35 | Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Second class Kail wood |
| 36 | Providing and fixing double glazed hermetically sealed glazing in aluminiumwindows, ventilators and partition etc. with 6 mm thick clear float glass both sidehaving 12 mm air gap including providing EPDM gasket, perforatedaluminium spacers, desiccants, silicon sealant (Both primary and secondarysealant) etc. as per specifications, drawings and direction of Engineer-in-chargecomplete. |
| 37 | Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 38 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 39 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 40 | Rough cast plaster upto 10 m height above ground level with a mixture of sandand gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over andincluding the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement |
| 41 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 42 | Thermal Insulation of roofing with Expanded polystyrene fixed with suitableadhesive to the false ceiling as per the directions of the Engineer-in-charge: With Type N - Normal 50 mm thick |
| 43 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture onwood work (hard and soft wood) |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture ofrequired colour to give an even shade :Two or more coats on new work over an under coat of suitable shade withordinary paint of approved brand and manufacture |
| 45 | Providing and applying white cement based putty of average thickness 1 mm ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 46 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coatwith cement primer |
| 47 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thicknessto be specified by the manufacturer) of 1st quality conforming to IS : 15622 ofapproved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with greycement slurry @ 3.3 kg/sqm including pointing the joints with white cementand matching pigment etc., complete. |
| 48 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622(thickness to be specified by the manufacturer ) of approved make in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge in skirting, risers of steps and dados over 12 mm thick bed of cementMortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shade complete. |
| 49 | Providing and fixing bright finished brass handles with screws etc. complete: 125 mm |
| 50 | Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete : 150x10 mm |
| 51 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodiccoating not less than grade AC 10 as per IS : 1868), transparent or dyed torequired colour or shade, with nuts and screws etc.complete 250x16 mm |
| 52 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and thebase support for tank |
| 53 | Providing & fixing White vitreous china water closet squatting pan (Indian type)along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trapat site complete with all operations including all necessary materials, labour anddisposal of dismantled material i/c malba, all complete as per the direction ofEngineer-in charge. Long pattern W.C Pan of size 580x440 mm |
| 54 | Providing and fixing white vitreous china wash basin including making allconnections but excluding the cost of fittings: Flat back wash basin of size 550x400mm. |
| 55 | Providing and fixing white vitreous china battery based infrared sensor operatedurinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water(250 ml & 500 ml consumption), having water inlet from back side, including fixingto wall with suitable brackets all as per manufacturers specification and directionof Engineer-in-charge. |
| 56 | Providing and fixing brass bib cock of approved quality 20 mm nominal bore |
| 57 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & makeas approved by Engineer in charge. 15 mm nominal dia |
| 58 | C.P. Brass angle valve 15 mm |
| 59 | Providing and fixing C.P. brass close hole basin mixer piller tap of approved quality and make, weighing not less than 1.970 kg |
| 60 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100mm diameter |
| 61 | Providing and fixing C.P. brass shower mixer approved quality. |
| 62 | Providing and fixing 40mm diameter with length not less than 700mwaste pipe for sink and wash basin |
| 63 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore |
| 64 | Providing and fixing toilet paper holder :C.P. brass |
| 65 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
| 66 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 67 | Providing and fixing 600x450mm bevell ededge mirror of superior glass (of approved quality) complete with 6mm thick hardboard ground fixed to wooden cleats with C.P. brass screws and washers complete. Rectangular shape 453x357mm |
| 68 | P/F cp jali of approved make. |
| 69 | Providing and fixing PVC waste pipe of regd. diameter with bends, tee bends, L head and P trap with adding material ISI marked like Prince, Supreme or equivalent and complete job. 75mm dia |
| 70 | Providing and fixing PVC waste pipe of regd. diameter with bends, tee bends, L head and P trap with adding material ISI marked like Prince, Supreme or equivalent and complete job. 100mm dia |
| 71 | Providing and fixing 3layerPP-R(PolypropyleneRandomcopolymer)pipesSDR 7.4UVstabilized&anti-microbialfusionwelded,havingthermalstabilityforhot &coldwater supply includingall PP-Rplain&brass threadedpolypropylene randomfittingsi/ctrenching.refilling&testingofjointscompleteasperdirection of Engineer in Charge. (External work)PN-16 Pipe, 40 mm OD |
| 72 | Providing and fixing 3layerPP-R(Polypropylene Random copolymer)pipesSDR 7.4UVstabilized & anti-microbial fusion welded,having thermal stability for hot &coldwater supply includingall PP-Rplain&brass threadedpolypropylene random fittingsi/ctrenching.refilling & testing of joints complete as per direction of Engineer in Charge. PN-16 Pipe, 25 mm OD (SDR-7.4) |
| 73 | Providing and fixing ball valve (brass) of approved quality complete: High or low pressure with plastic floats:20 mm nominal bore |
| 74 | Providing and fixing white vitreous china flat back or wall corner type lipped fronturinal basin of 430x260x350mm and 340x410x265mm sizes respectively. |
| 75 | Providing and fixing stone slab with table rubbed, edges rounded and polished, ofsize 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chaseof appropriate width with chase cutter and embedding the stone in the chasewith epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 6 mm nominal size) as per direction of Engineer-inchargeand finished smooth. Granite Stone of approved shade |
| 76 | Providing and fixing insulation works of PPR pipe by way of using K flex ,polythene,glass wool,chicken mesh and cover with aluminium foil on outer exposed pipe complete job. |
| 77 | Providing and fixing heat tape 33 watts of multi layer including wiring over pipe line in spring shape all complete job (demforced or chromlex or equivelent |
| 78 | providing and fixing insulation work on PPR pipe by using K flex, polythene.(inner pipe in bath)25mm dia |
| 79 | providing and fixing of material for the insulation of water storage Tank of with nitrile sheet tapping with cello tape Rock wood 6 inch per side wire mesh polythene aluminium sheet 26 guage cladding with dia complete job 19mm thick nitrile sheet complete job. |
| 80 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design |
| 81 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. group A |
| 82 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 83 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. A ) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 84 | b ) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 85 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 86 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excludin modular plate etc. as required. a) 5/6 A switch |
| 87 | 3 pin 5/6 A socket outlet |
| 88 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 89 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No.s 3 pin 5/6 A modular socket outlet and 2 No.s 5/6 A modular switch, connections etc. as required |
| 90 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 91 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a ) 6way (4 + 18), Double door |
| 92 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.A ) Single pole 6 /16 amp |
| 93 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a ) 25mm |
| 94 | Supply, installation , testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length , with 3mm thick the electrode should be hot dip galvinised . The GI Electrode shall be pre filled with cristaline Conductive Material ( CCM ) . The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco - friendly GI Electrode Earthing should be eco - friendly GI Electorde Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. |
| 95 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at |
| 96 | Supplying and fixing following rating and breaking capacity and pole MCCB with thermagmetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel making connections etc as required MCCB FP 100 Amp 36 KA |
| 97 | Fabrication, supplying , installation testing and commissioning of following pannel made out of 2mm thick M.S sheet , floor mounted , vermin & dust proof, indoors , duly painted with provsion for fixing of1 nos incomer MCCB, , MCCB type change over switch - 1 No including supply and fixing 2 set of Aluminium bus bar and strip for housing MCB,s 24 Nos , MF Digital Meter and other allied accessories as required ( Make as per annexure |
| 98 | Supplying and fixing of following rating 240 /415 Volt \\" C\\" series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connection , testing and commissioning.( Above to 32 Amp) a ) SPN 63 Amp |
| 99 | Supplying and fixing of following electrical items suitable for operating on 240 /230 volts AC, 50 HZ supply , including connection etc. as required. Exhaust fan 300 mm size ( Heavy duty) CG transair or equivalent approved make |
| 100 | Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE at power cable of following sizes on surface / surface cables tray , 0.50 mtr below ground level etc. as required including carriage upto site of work ( Make as per annexure enclosed) 35 Sqmm 3.5 Core Armoured |
| 101 | Supply and fixing LED type Down Lighter of following ratings 12 watt |
| 102 | Carriage of material Cement and steel by an average lead ........................... 05 km |
| 103 | Sand by an avg lead ..................................... 7 km |
| 104 | Stone by ang lead …................................... 15 km |
| 105 | Stone aggregate by an avg lead of …....................... 15 km Please Enable Macros to View BoQ information |