| 1 | LWSS Namhol 2nd StageSupply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-Discharge:-13.70 LPS, Total Dynamic Head :-360mtrs Suction lift:-Positive, Dia of Rising Main :-125mm ,Length of R/Main :-1600mtrs, Pumping Hours:-8 Hours. |
| 2 | Providing and laying copper PVC insulated armoured power Multi core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor & as per directions of Engineer-in-Charge. Motor side: suitable capacity/ size Min length = 20 mtrs.Supply side:suitable capacity/ size Min. length =20 mtrs.Quantity= 1 Job |
| 3 | Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity & any other fittings required as per site conditions & as per directions of Engineer-in-Charge. Quantity= 1 Nos. |
| 4 | Supply of Kirloskar/Kilburn/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1.00 Provided with hand wheel/Cast iron Cap. Quantity= 2 Nos |
| 5 | Supply of Kirloskar/KSB/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² Quantity= 1 Nos |
| 6 | Supply of Kirloskar/KSB/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^²Quantity= 1 Nos |
| 7 | LWSS SilhaSupply and errection of horizontal spindle horizontal split casing/ multistages centrifugal/reciprocating pumps of standard make such as KSB/Mather platt / Kirlosker/WASP by the Department conforming to BIS-1520-1980 approprite IS/ISO 9001-2000 code ( with upto date ammendments ), read with IS: 9137-1978 or latest to handle clear water having turbidity 50 ppm.with impellers , casing ring &shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity where ever applicable coupled directli through a flexible coupling on a common base plate to Motor of Kirloskar/NGEFl/Crompton/Marathan/Jyoti and suitable for operation on 400 (+)/(-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-Discharge:-2.50 LPS per set, Total Dynamic Head :-230mtrs (1 No Working )Suction lift:-Positive, Dia of Rising Main :-40mm ,Length of R/Main :-576mtrs, Pumping Hours:-8 Hours. |
| 8 | Supply, Installation, Testing and Commissioning of suitable electrical control Pannel cubical type powder coated with star-Delta-Starter push button type, main incomer MCCB of required capacity, Volt meter 0-500 volts,Ampare meter 100/5 Amp., ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB, power capacitor of required capacity under voltage/over voltage release, over current earth fault relays,suitable to operate all 415 volatage +,- 10% AC supply all equipments shall be of make of L&T/ Havells make complete in all respects including all required accessories of required capacity.Quantity= 1 Nos |
| 9 | Providing and laying copper PVC insulated armoured power Multi core cable (one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.Motor side: suitable capacity/ size Min length = 15 mtrs.Supply side:suitable capacity/ size Min. length =15 mtrs.Quantity= 1 Nos Please Enable Macros to View BoQ information |