| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 3 | Cement Concrete 1:5:10 with stone ballast using mechanical mixer volumetric type. |
| 4 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 5 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 6 | Shelves |
| 7 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 8 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 9 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 10 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 11 | 20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen 1.65 Kg. per Sqm. hot laid and sanded. Vertical |
| 12 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 13 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 14 | Ground Floor |
| 15 | First Floor |
| 16 | Extra rate for First Floor |
| 17 | First class burnt brick work laid in cement sand mortor 1:4 in first storey upto 4 metres above plinth level. |
| 18 | Extra for burnt brick work in square or rectangular pillars in building. |
| 19 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 20 | Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12mm thick cement plaster 1:4 or pointing as required. |
| 21 | Extra rate for Smooth Surface of Ceiling. |
| 22 | 12.5mm thick cement plaster 1:4 |
| 23 | 20 mm thick cement plaster 1:5 in two coats work. |
| 24 | 12.5 mm thick cement plaster 1:4. |
| 25 | 20mm thick cement plaster 1:4 in two coat work. |
| 26 | Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 27 | Bearing plaster of 10 mm thick cement plaster 1:3 cement sand finished with a floating coat of neat cement and thick coat of lime wash/POP on top of walls when dry for bearing of RCC slabs and beams. |
| 28 | Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) |
| 29 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 30 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 31 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 32 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 33 | Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating |
| 34 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement |
| 35 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 36 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead with in area lead 3Km |
| 37 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
| 38 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling |
| 39 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 40 | Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing |
| 41 | Extra labour for projected nosing of stair case of any shape and design |
| 42 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 43 | Extra rate for Tiles to be laid with 3mm gap using spacer & later this gap to be filled with cement based grout and matching pigments etc complete in all respects |
| 44 | Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings. |
| 45 | Conglomerate floor 50mm thick cement concrete topping 1:2:4. |
| 46 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. |
| 47 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg/rmt |
| 48 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, Cillral mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) |
| 49 | Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect |
| 50 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. |
| 51 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 52 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick or 10.75 Kg/ Sqm exceeding 0.40 sqm area. |
| 53 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 54 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm Thick |
| 55 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 56 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 10mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for stiles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the stiles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 57 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 58 | Providing & Fixing Lock to aluminium doors of approved make as desired by Engineer-in-Charge |
| 59 | Providing & Fixing door closer 701-850 mm of approved make as desired by Engineer-in-Charge |
| 60 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) |
| 61 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 62 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 63 | Extra for providing Polyster Powder Coating to aluminium extruded sections (minimum thickness of Powder coating 50 micron). |
| 64 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 65 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 66 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) |
| 67 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.With ordinary quality Paint |
| 68 | Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron workWith ordinary quality paint |
| 69 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 70 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 71 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 72 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 73 | Construction of Plinth protection complete as per drawing. |
| 74 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 75 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer volumetric type. |
| 76 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 77 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads. |
| 78 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling |
| 79 | Conglomerate floor 40mm thick cement concrete topping 1:2:4. |
| 80 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. |
| 81 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipecomplete in all respect |
| 82 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design andpattern will be as per guidelines issued for persons with disability) |
| 83 | Cement concrete 1:8:16 |
| 84 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 4mm thick ACP Sheet |
| 85 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey andpattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code 15658 (2006) |
| 86 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 87 | Construction of cement concrete Kerb with top and bottom width 115 and 165 mm respectively, 300 mm high in M 20 grade Kerb stone laid with Kerb laying machine, all complete as per clause 408 |
| 88 | Painting one coat with creosote |
| 89 | Painting Two coat with creosote |
| 90 | Providing and Fixing of Reception Counter including panneling on back complete as per drawing/design as desired by Engineer-in-Charge. (Rs. 32000 + GST @18% = Rs.37760/-) |
| 91 | Electrical Services only |
| 92 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 93 | Wiring fan point (With fan box) |
| 94 | Wiring light point |
| 95 | Wiring call-bell point |
| 96 | Wiring 6 Amp. wall socket point |
| 97 | Wiring 6 Amp. Plug control comprising wall socket point |
| 98 | Wiring 16/20 amp. power plug control point |
| 99 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 100 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 101 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 102 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 103 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 104 | Overall size 1.5sq.mm (Un-sheathed) |
| 105 | Overall size 2.5sq.mm (Un-sheathed) |
| 106 | Overall size 4sq.mm (Un-sheathed) |
| 107 | Overall size 6sq.mm (Un-sheathed) |
| 108 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 109 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 110 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 111 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 112 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 113 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 114 | Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 115 | Overall size 16sq.mm (2Core) Un-armoured (Loose) |
| 116 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 117 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 118 | PVC flexible pipe 32mm dia. |
| 119 | G.I. EARTHING: |
| 120 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 121 | Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length) |
| 122 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). |
| 123 | Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length) |
| 124 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 125 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 126 | Ceiling Rose (Flush Piano type) |
| 127 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 128 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 129 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 130 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 131 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 132 | SP&N Double Door Distribution Board 12 way each |
| 133 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): |
| 134 | On Load Change Over Switch Four Pole 63amp., 415volts |
| 135 | Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3Nos. shrouded neutral bars, 3Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 136 | TP&N Double Door Phase Segregated Distribution Board 6 way each |
| 137 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 138 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 139 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 140 | Ceiling Fans & LED Light Fixtures: |
| 141 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. |
| 142 | Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Trade Name : Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. |
| 143 | Supply and erection of recessed mounted 36 WATT LED panel 2x2 (including constant LED driver) with CRACA sheet having efficency of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory |
| 144 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 145 | Supply and Erection of 50 Watt LED Flood Light fitting (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 146 | Supply and Erection of Wall fan plastic body 400mm 16\\" including flexiible wire and petty material etc. for connection and testing complete in all respects as desired by the Engineer in charge of work at site. |
| 147 | NETWORKING |
| 148 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 149 | Wiring Telephone socket point RJ11 (one module) |
| 150 | Wiring Networking socket point RJ45 (one module) |
| 151 | COPPER CONDUCTOR CABLE FOR SPECIAL ELECTRICAL SERVICES: |
| 152 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulated with star separator, 4 pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E Standard left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge. |
| 153 | CAT 6 LAN cable |
| 154 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 155 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 156 | Supply & Erection of POE Powered Indoor Wi-Fi Access Point 1 Gbps Speed having 2.4Ghz and 5Ghz network, omni directional antenna, 01 No. Giga WAN port and, Password Protection, Wide Area Range, Ceiling /Wall Mount Flow Control, App Controlled, IEEE 802.3at PoE, Up to 100 Wi-Fi Users, Security Protocol WPA/WPA2/WPA3™ Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control Power Supply Connect 12 V / 2.5 A (optional power adapter not included), IEEE 802.3at PoE, Support Port Forwarding, NAT Etc complete in all respects as desired by the Engineer in charge of work at site. |
| 157 | SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site.. |
| 158 | Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. |
| 159 | Supply & installation of 1KVA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. |
| 160 | Supply and erection of Complete Patch Cord With 1 Mtr Length (3 feet) 10/100/1000 Make D LINK/ Digilink/ Amp. Erection and connection with petty material Complete in all respect as approved and desired by engineer at site |
| 161 | Supply, Installation, testing of Panasonic set with caller ID features and 20 defined keys, handfree speaker and ringer indicator |
| 162 | Public Health Services |
| 163 | providing laying , jointing fixing and testing ISI marked PVC pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 164 | 20mm i/d |
| 165 | 25mm i/d |
| 166 | 32mm i/d |
| 167 | 50mm i/d |
| 168 | Providing fixing and jointing ISI marked gun-metal peet valves (heavey pattren ) as pewr IS 778 with hand wheels, on G.I. pipe lines laid in the ground of inside building including all carriages complete. |
| 169 | 20mm i/d gun metal peet valve heavy pattren. |
| 170 | 25mm i/d gun metal peet valve heavy pattren. |
| 171 | 32mm i/d gun metal peet valve heavy pattren. |
| 172 | 50mm i/d Gun Metal peet valve heavy pattern. |
| 173 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. |
| 174 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 175 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 176 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 177 | 100mm i/d SWR UPVC pipe lines laid complete |
| 178 | 75mm i/d H.C.I. pipe lines laid complete |
| 179 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 180 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 181 | With C.P. Brass nut |
| 182 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. |
| 183 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 184 | Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling |
| 185 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 186 | C.P. brass Bib cock without flange |
| 187 | Providing & fixing in position C.I gully trap cover weighing approximately 7.26 kg and frame for gully trap camber clear opening size 300mm x 300mm and outside size 330mmx330mm including painting the exposed surface with 3 coats of black bit mastic superior paint of approved make (to the approval of Engineer-in charge). |
| 188 | Providing & Fixing H.C.I. floor traps conforming to ISI specification (IS:1729) of approved make (to the approval of Engineer-In-Charge) of the self cleaning design with CP brass hinged grating with fram eith or without vent arm and including cement concrete 1:2:4 under and around the floor level complete in all respects including cutting and making good the walls and floors etc. minimum depth of water should be 150mm with a minimum seal 50mm. |
| 189 | (b) with 75mm i/d outlet deep seal. |
| 190 | Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 191 | Heal Rest Bend (100mm) |
| 192 | Heal Rest Bend (75mm) |
| 193 | Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 194 | Cowls |
| 195 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 196 | Providing & fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer -in-charge) complete in all respect. |
| 197 | For 1000 ltr capacity tank and above |
| 198 | Construction of Septic Tank size 5.00 Mtr x 3Mtr. Internal size with 2.5 Mtr. Internal depth in brick masonary, 4 no. chambers medium duty man hole cover complete as per drawing/specification andto the entire satisfaction of Engineer-in-charge |
| 199 | Earth work in excavstion in Foundation Tranches etc, for storage and sadimentation tanks. (CSR 29.02) |
| 200 | Cement concrete 1:4:8 With stone aggregate 40mm gauge (CSR 10.11) |
| 201 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth. (CSR 11.7) |
| 202 | Reinforced cement concrete M-20mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (CSR 10.15) |
| 203 | Centring and shuttering for sides and sofffit of beams launchings girders bressumers, lintels (CSR 9.6) |
| 204 | Cols twisted deformed (ribbed/tor steel) bars for RCC works, where not included in the complete rate of RCC including bending, binding and placing in position complete. (CSR 18.18) |
| 205 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (CSR 9.8) |
| 206 | Cement concrete 1:2:4(CSR 10.13) |
| 207 | Cement rendering on plaster 1mm thick (CSR 15.48) |
| 208 | 10mm thick cement plaster 1 : 4 on floors.CSR 15.38) |
| 209 | 12.5 mm thick cement plaster 1:2CSR 15.7 |
| 210 | Cement rendering on plaster 1mm thick (CSR 15.48) |
| 211 | Providing and fixing 560 mm,500mm and 450 mm internal Diameter circular or 455x610 clear inside opening rectangular cast iron manhole covre and frame ISI marked as per IS12992-2002 (Csr 29.36) |
| 212 | Fixing SW pipe inlet and outlet connection in pit walls |
| 213 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material. |
| 214 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 215 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
| 216 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry@ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 217 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 218 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to theapproval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 219 | AUTOMATIC VOLTAGE STABLIZER: |
| 220 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step uptransformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulatedinside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) ofsuitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 voltinput (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 221 | Automatic Voltage Stablizer 2 KVA |
| 222 | Providing & Installing split type wall mounted air conditioner capacity 2.00 tonne with 4 kw voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 223 | Providing & Installing split type wall mounted air conditioner capacity 1.5 tonne with 4 kw voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 224 | Providing & Installing split type wall mounted air conditioner capacity 1.0 tonne, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD unit. stands for OD unit and concealing of copper pipes and drainage pipe within the building and installing charges complete in all respects. |
| 225 | Providing & Installing Bottle Water Dispenser |
| 226 | Providing & Installing Refrigerator 210Ltr |
| 227 | Providing & Installing Stablizer Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail