| 1 | Mandi waste Powered Cold Room Biomass/Farm waste/ Crop waste Powered Cold Room - Automated PLC System/Control panel - Electronic Thermostat For Temperature Control - Air Cooling unit with single fan cold Room -Hot water genrator-cooling Tower FRP Type - Temperature Monitor& Controller (1° C to Cold Room) Cold Room - Refrigeration pipeline(Suction and vapour line) - Chamber of size 7.32x3.66x2.74 Mtr having 80 mm puff pannel(floor) and 80 mm wall/door/ceiling insulation Remote Monitoring System (RMS) -Temperature logging - Data accessible to user through a web interface - Live Camera streaming inside cold room Grid Backup to Biomass Powered Refrigeration -Danfoss Make Compressor MLZ030 - Indoor Unit with Control Panel - Includes Copper piping - includes stabilizer -Temperature Monitor& Controller(1° C to 25 °C) For Cold Room Mandi Waste Shredder - Chaff Cutter x 1no - 300-500 kg per Hour Output Humidifier Shipping and installation (excludes civil work) Product operational support for 1 year from date of commissioninng |
| 2 | 02nd year Opration For workmanship charges of Technician of Biomass system 20 MT Cold Room (DSR-2025 E&M- 1020) |
| 3 | 03rd year Opration For workmanship charges of Biomass system 20 MT Cold Room (DSR-2025 E&M- 1020) |
| 4 | Drilling of 150 mm dia T/W bore suitable for 110mm dia pipe/200mm dia T/W bore suitable for 140 mm dia pipe all complete with labour T/P as per direction of engineer incharge (Jal Nigam) |
| 5 | Supply and lowering of 110 mm dia 6kg/cm2 PVC pipe/140mm dia 10kg/cm2 with plastic net cover slots of pvc pipe by UPIN(phenolex or apb by E/I) all complete (ISI mark only) SOR 2017-18 (Jal Nigam) |
| 6 | Supply and pouring of pee gravels suitable for T/W bore all complete as per direction of engineer incharge (Jal Nigam) |
| 7 | S/F of 110mm PVC pipe adopter suitable for item no. 2 (Jal Nigam) |
| 8 | Supply of 2 HP submersible pump set with starter UPIN 65m head ( Pluga/Crompton Greeves/KSB) (GEM) |
| 9 | Supply and fitting of 4sqmm 3 core copper wired submirsible cable (ISI mark) complete in all respect (Jal Nigam) |
| 10 | Supply and lowering of 40 mm dia ribbed screen Ashirvad PVC pipe (ISI marked)/ 32 mm dia G.I. Pipe by UPIN and fixed with boat site threaded SS nipple all complete. (Jal Nigam) |
| 11 | Transportation of all material T&P etc to the site of work, loading, unloading and proper stacking at the site including return cartage of unused material with the diging the pit of boring work including supply all labour T&P with with arrangement of water required etc all complete. (Jal Nigam) |
| 12 | Installation of 2.00HP submersible motor pump with 32mm G.I. Lowering, submersible cable 4sqmm & installation of starter including supply of labpur, T&P etc complete in all respect (Jal Nigam) |
| 13 | Devlopment of bore hole till the discharges of water become free from sand and turbidity by compression and disinfection of bore including supply of all labour T&P (Jal Nigam) |
| 14 | Chemical & bacteriological testing of water sample (Jal Nigam) |
| 15 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (SI No. 725(A)) |
| 16 | Supply and fixing of one number 8 to 6 SWG G.I.Wire in 15 mm dia G.I. pipe for ear thing ,laid in ground or in wall duly concealed including the cost of cement ,sand .lab our , T&P other material required for proper completion of the work as directed at site. (SI No. 721) |
| 17 | S/F of 32 mm dia G. I. Pipe complete with G. I. Fittings, clamps including all materials, Labour etc complete in all respects. (DSR 18.12.4) |
| 18 | Providing, laying and fixing 50mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc (DSR 18.12.6) |
| 19 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade on Wall Surface as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. (i) 16 sqmm 2 core (SI No. 20c.1.3) |
| 20 | S/F of 6 Amp to 32 Amp SPMCB (10 KA) C Curve Cat A (SI No. 1002) |
| 21 | S/F of 6 Amp to 32 Amp.DPMCB (10 KA) C curve Cat A (SI No. 1009) |
| 22 | S/F surface/flush mounting 4 way SPN distribution board with additional metal door without MCB complete in all respect and as directed at site. Cat A (SI No. 1022A) |
| 23 | S/F of CP brass bib cock 15mm of approved make complete in all respects. (DSR 7257) |
| 24 | S/F of gun metal non return valve 32mm of approved make complete in all respects. (DSR 1934) |
| 25 | Supply and fixing of 63 Amp. 415 volts TPN metal clad rewirable type switch fuse unit on angle iron bracket complete in all respects. (S.I. No. 316) |
| 26 | Supply and fixing of brass stop cock of approved make complete in all respects. (S.I. No. Civil DSR 7260) |
| 27 | Supply and hosting of sintax or equivalent high density polythylene seamless of piece mould tank complete in all respect (Jal Nigam) |
| 28 | Supply and fixing of LED Street Light Fitting having die cast Aluminium body and diffuser with driver set suitable for 110 to 130 watt. Confirming to IP 65 and above protection complete in all respect. CAT.AAA (S.I. No. 23.17) Please Enable Macros to View BoQ information |