| 1 | 1.6 mm to 4.8 mm Lal-Qua/ chandigarh pea gravel screened and washed with stacking (As per current market rates) (based on uppwd / SOR-2020 ) |
| 2 | Pumping out water by Diesal Pump set of capacity 4000 litres/hour. (based on uppwd / SOR-2020 ) |
| 3 | Supply of Labour for silt cleaning in UGR tank (based on uppwd / SOR-2020 ) |
| 4 | Supply of Supervisor for Supervision 8km long pipe line & Leakage (based on uppwd / SOR-2020 ) |
| 5 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50m and lead upto 30M and including filling watering and ramming of excavated earth into trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30M from the foundation trenches. (UPPWD/SOR-2020/251(b) Depth from 0.0 to 1.5 M below G.L. |
| 6 | Providing and Laying of 12” dia pipe with 6mm thickness MS Jindal / Appolo / Tata Make pipe including supply of all materials, labour, T&P etc. required for completion of the work as per direction of Engineer-In-Charge/ Authority Consultant. |
| 7 | Repairing existing AC/CI/DI water line i/c all rerquired materials such as CID Joints, rubber packing nut & bolts, bailing out of water, all labour and T&P i/c cutting of pipe etc. complete work as per direction of E/I (But Excluding cost of excavation filling and M.S. Spacials) Based on NOIDA 300 mm dia |
| 8 | Proper Running , Operation of Under Ground Reservoir Including D G Set, Electrical panel, Starter and minor Electrical fault, sweeping of area , cleaning of all equipment's ( MOTOR,STARTER,PANEL,D.G.SET etc.) in all complete as per direction of E/1 and also Operation of sluice valve installed in UGR compound round the clock watch & ward would be the responsibility of the contractor. The Contractor is bound to get approval of Operator/ Helper (Each person/Each Shift) from Engineer lncharge and also paid minimum wages as per current SOR. Cost for One Month for Water Works Compound with 01 Nos AOR |
| 9 | PVC Flexible cables copper conductor 1100 V conforming to 694/1990 double sheathed circular rate including excise duty, sales tax (make - Tridev Electricals /Uttam Engineering Works/ Sweta Electricals) 10 sqmm x 3core AOR |
| 10 | PVC Flexible cables copper conductor 1100 V conforming to 694/1990 double sheathed circular rate including excise duty, sales tax (make - Tridev Electricals /Uttam Engineering Works/ Sweta Electricals) 35 sqmm x 3core AOR |
| 11 | Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (CCI, Fort Gloster , Asian , Universal , Nicco , ICL , Diamond, Havells & KEI make & for small works upto value of cable for Rs. 25.0 lacs Kalinga, Suraj, Delton, Grandley & Polycab & KEI UPPWD-2018 P.S.-501 3.5Cx50 sqmm. |
| 12 | Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (CCI, Fort Gloster , Asian , Universal , Nicco , ICL , Diamond, Havells & KEI make & for small works upto value of cable for Rs. 25.0 lacs Kalinga, Suraj, Delton, Grandley & Polycab & KEI UPPWD-2018 P.S.-5013.5Cx300 sqmm. |
| 13 | Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armored cable jointing. Complete in all respect as required for proper completion of work As per direction of Engineer-in-charge. (Make Raychem, CCI, Forntec). YEIDA SOR-73.5/4CX50Sq.mm. |
| 14 | Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armored cable jointing. Complete in all respect as required for proper completion of work As per direction of Engineer-in-charge. (Make Raychem, CCI, Forntec). YEIDA SOR-7 3.5/4CX300Sq.mm. |
| 15 | S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. UPPWD-2018 P.S.-504 50 Sqmm. |
| 16 | S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. UPPWD-2018 P.S.-504 300 Sqmm. |
| 17 | Supply, delivery, laying, testing & commissioning of 11KV (E) XLPE cable having compact circular stranded aluminium conductor the conductor should have screening of extruded semi conducting compound, cross linked polythylene (XLPE), insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand all-round and protected with bricks on sides and at the top surface. The cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I. with Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respect and as per requirement of the job under the direction of Engineer-in-charge. Make- CCI, Gloster, Asian, Universal, Nicco, ICL, Diamond, Havells & KEI. YEIDA SOR-2 3CX300 Sqmm. |
| 18 | Supply, Installation, Testing & Commissioning of 11 KV Out door type cable termination kit of 3 core cable with cable termination at the panel & transformer complete in all respect as required for proper completion of work as per direction of Engineer-in-charge.(Make Raychem/C.C.I./Frontec) YEIDA SOR-5 3CX300 Sq.mm. |
| 19 | Supply, Installation, Testing & Commissioning of 11 KV Straight through cable jointing kit of 3 core cable with cable jointing. Complete in all respect as required for proper completion of work as per direction of Engineer-in-charge. (Make Raychem/C.C.I./ Frontec ) YEIDA SOR-6 3CX300 Sq.mm. |
| 20 | Repair of Transformer Incl. Changing of HV & LV Coil, Bushing, Gasket & Fresh Transformer oil without returnning of old & unsearciable material. as directed by Engineer in charge 63/100KVA Transformer AOR |
| 21 | Dis./Re-errection of 63/100 KVA Al./copper wound outdoor type Transformer.per ISS including fess as directed by Engineer in charge AOR |
| 22 | Supply & Fixing of PVC Insulation Tape 19/20mm 8Mtr Long.(Steel grip) complete in all respect, as directed by Engineer in charge. YEIDA SOR-44 |
| 23 | Digging of (Excavation) trench as per direction of Engineer-in-charge complete in all respects. AOR |
| 24 | S&F of 250 Amp, 4Pole MCCB (25KA) Thermal Magnetic Relase . UPPWD-2018/PS-1021 (G) |
| 25 | S&F of 125 Amp, 4Pole MCCB (16KA) Thermal Magnetic Relase . UPPWD-2018/PS-1021 (A) |
| 26 | S&F of 6 Amp To 32Amp.SPMCB (10KA) C Curve. UPPWD-2018/PS-1007 ( C) |
| 27 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable.Based DSR-2018/1101 |
| 28 | 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable.Based DSR-2018/1102 |
| 29 | Supply, Sagging, tensioning, jointing and bending of suitable size ACSR conductor conferming to I.S. specification including cost of aluminium wire and jointing sleeve required. The rates includes cost of material, labour, T&P etc. required for proper completion of work as per the directions of the Engineer-in-charge. PWD-2018 P.S.-627 Rabbit conductor. |
| 30 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 watt to 90 Watt. Confirming to IP 66 protection complete in all respect (Make Philips, Crompton, Bajaj,) complete in all respect, as directed by Engineer in charge UPPWD-2018 PS-1423 Cat-AAA |
| 31 | S/F of 40mm. dia 1.5mtr. long G.I. pipe ‘B’ Class bracket with 2 Nos. ‘D’ clamps 50X6mm. flat iron on steel tubular pole/ steel rail pole / PCC pole with bolts, nuts etc. complete in all respect, as directed by Engineer in charge YEIDA SOR-35 |
| 32 | Supply & Fixing of XLPE insulated, Copper un-armoured Control cable 1100V grade etc.make- CCI, Gloster, Asian, Universal, Nicco, ICL, Diamond, Havells , KEI Make & for small works upto value of cable for Rs. 25.00 Lacs Klinga, Suraj, Delton, Grandley & Polycab make can be used as per the directions of the Engineer-in-charge YEIDA SOR-1 3CX2.5 Sqmm Please Enable Macros to View BoQ information |