| Sl. No. | Item Description |
| 1 | Supply and delivery of 11KV, 800Amps., triple pole, 26.3 KA,Three Panel Horizontal draw out & Horizontal isolation Indoor VCB as per major technical specifications below :-(Make:- PASCAL / Alstom/Beicco ) 1 No. Incomer PanelMOVING PORTION :-a) 11KV, 800Amps., 26.3 KA draw out type Vacuum Circuit Breaker with Motorised independent Spring charge Mechanism suitable for 240 volt AC, Closing & Tripping Coils Rated 110 volt DC.b) Vaccum Interrupter(Make : ABB)- 3 Nos.c) Mechanical ON / OFF indicator - 1 set d) Auxiliary Switch ( 4NO + 4 NC )Imax - 1 set e) Automatic safety shutters. – 1 set f) Mechanical interlocks. - 1 set.FIXED OR IMMOVABLE PORTION : a) Fully compartmentalised sheet steel totally enclosed floor mounted with automatic safety shutter, Horizontal drawout & Horizontal Isolation alongwith insulated PVC sleeve, 800 A copper busbar, foundation bolts etc. with provision for Rear entry cable termination arrangement / box for 3Cx185 sq mm PILC / XLPE , HT power cable. b) Epoxy resin cast Duel Core C T ratio 50 - 25 / 5 - 5 with protection class - 5P10 and Metering class - 1, Burden 15/15 VA & adequate STC for 1 sec.– 3 nos.c) 3 phase, 11KV/√3 / 110V/√3, 100 VA , 3 limb star / star connected draw-out type resin cast P.T. with 100VA per phase output at Class – 1 accuracy for metering purpose provided with necessary HT / LT fuses, shutters, etc. - 1 set. |
| 2 | BREAKER PANEL INDICATION LAMPS :- a) LED type Red / Green / Amber etc. indicator lamps for Bkr. ON / OFF /Auto Trip / Trip Ckt. Healthy / Spring Charge / TCH / ETC for indication.- 1 set b) P. T. indication R / Y/ B - LED Lamp- 1 setc) Cubicle panel illuminating Lamp - 1 setSWITCH AND ACCESSORIES :- a) Panel space Heater, Thermostat with ON / OFF switch-- 1 setb) T-N-C Switch , Motor ON /OFF Switch & etc.RELAY :- a) IDMT Relay, Type: CDG31, as Triple pole non directional shunt trip OCEF relay having 2 over current element of setting 50 – 200% and 1 earth fault element of 20 – 80% with high setting instance. Make : Areva / Alstom / Equivalent - 1 Set b) Master tripping relay,Type: - VAJH-13 Make : Areva / Alstom / Equivalent -- 1 set MEASURING INSTRUMENT:-a) Digital type Ammeter with Selector switch, Make:Schneider / Selec / Secure / equivalent -- 1 set b) Digital type Voltmeter with Selector switch ,Make:Schneider / Selec / Secure / equivalent -- 1 set c) 3 phase,Digital Multi-Function Meter, Make: Schneider / Selec / Secure / equivalent -- 1set Other items :- power pack , input : 110 VAC & Output : 110VDC, 3PH- 4W, Burden : 300/500 VA , Storage : 4 Close + 4 Trip Cycles 30 sec. |
| 3 | 2 Nos. outgoing Panel MOVING PORTION :-a) 11KV, 800Amps., 25 KA draw out type Vacuum Circuit Breaker with Motorised independent Spring charge Mechanism suitable for 240 volt AC, Closing & Tripping Coils Rated 110 volt DC.b) Vaccum Interrupter, Make : ABB / EQUIVALENTc) Mechanical ON / OFF indicator -- 1 set d) Auxiliary Switch ( 4NO + 4 NC ) -- 1 set e) Automatic safety shutters. – 1 set f) Mechanical interlocks. -- 1 set FIXED OR IMMOVABLE PORTION :-a) Fully compartmentalised sheet steel totally enclosed floor mounted with automatic safety shutter, Horizontal drawout & Horizontal Isolation alongwith insulated PVC sleeve, 800 A copper busbar, foundation bolts etc. with provision for Rear entry cable termination arrangement / box for 3Cx185 sq mm PILC / XLPE , HT power cable. b) Epoxy resin cast Duel Core C T ratio 50 / 25 / 5 - 5 Amp with protection class - 5P10 and Metering class - 1 , Burden 15 / 15 VA & adequate STC for 1 sec. – 6 nos.BREAKER PANEL INDICATION LAMPS :- a) LED type Red / Green / Amber etc. indicator lamps for Bkr. ON / OFF /Auto Trip / Trip Ckt. Healthy / Spring Charge / TCH / ETC for indication.- 1 set b) Cubicle panel illuminating Lamp - 1 set |
| 4 | SWITCH AND ACCESSORIES :- a) Panel space Heater, Thermostat with ON / OFF switch -- 1 setb) T-N-C Switch , Motor ON /OFF Switch & etc.RELAY :- a) IDMT Relay, Type: CDG31/153/7SR10, as Triple pole non directional shunt trip OCEF relay having 2 over current element of setting 50 – 200% and 1 earth fault element of 20 – 80% with high setting instance. Make : Areva / Alstom / Equivalent -- 1 Setb) Auxiliary Relay , Transformer Protection Relay, Type: VAA-33, Make : Areva / Alstom / Equivalent -- 2 set c) Master tripping relay,Type: - VAJH-13 Make : Areva / Alstom / Equivalent -- 1 set d) 6/8 Window Annunciator(EAPL) - 1 Set MEASURING INSTRUMENT:a) Digital type Ammeter with Selector switch, Make:Schneider / Selec / Secure / equivalent -- 1 set b)Digital type Voltmeter with Selector switch, Make:Schneider / Selec / Secure / equivalent -- 1 set c) 3 phase,Digital Multi-Function Meter, Make: Schneider / Selec / Secure / equivalent -- 1set |
| 5 | Mandatory Type Test :-(As per IS 3427 & IEC 62271 - 200 clause - 6)The following test have to be conducted from any Govt. NABL accridated laboratory. 1. Lightning Impulse voltage withstand Test at 75 kv peak2. Dry Power Fequency Voltage withstand Test (sub clause - 6.2)3. Short Time withstand current and Peak withstand current Test at 25KA for 3 sec. with initial peak 66KA for main ckt. & 25KA for 1 sec. with initial peak 66KA for each ckt. (sub clause- 6.6 of IEC 62271-200, & 62271-100, 2008)4. Temparature Rise Test at 800 Amp., 50 Hz.(sub clause - 6.4 & 6.5)5. Mechanical Operation Test at ambient air temperature ( class M2 & IEC 62271-100, 2008) : 10,000 Operation6. Degree of Protection IP5X, ( IS 13118 & IS 3427 , IEC 62271 - 100 & 62271 - 200 ) 7. Internal arc test --- .01 sec [Photo copies of certificates to be uploaded in online for above]Routine Test : - As per IS 13118 , IEC 62271 - 100(2008) & 62271 - 200(2003)1. Power Fequency withstand Test on Main Circuit Auxiliary Circuit and Control Circuit2. Power Fequency Voltage Test for 1 Min. between Terminal with Breaker ON/OFF3.Mesurement of the Resistance of main Circuit4. Mesurement of opening and closing times 5. Mechanical Test 6. Paint Shade : RAL- 7032 |
| 6 | Terms & Condition:- 1. Guarantee period 18 months from the date of delivery and 12 months from the date of installation & commissioning.2 Price variation clause will not be entertained.3. Materials should be delivered at work site / concerned Section office in consultation with the Executive Engineer.4. All sorts of Test Certificate must be submitted from the manufacturer at the time of delivery of materials to the concerned officers.5. Validity offer to be mentioned specially & clearly.6. Quantity may be increased or decreased as per actual requirement.7. All mandatory NABL accridated test certificateswill have to be submitted with Bid Documents during e-tendering.8. The manufacturer must submit closing and tripping time curve after testing on abreaker analyzer. For major components like C.T, P.T, Meter and relays the routine test certificate of the respective manufacturers need to sbmitted. 9. Bidder will arange the technical personnel of manufacturersto be present at site during commisioning .No extra cost can be claimed for this purpose. |
| 7 | SUB-HEAD 2:- TRANSFORMERS Supply & lnstallation of 500 KVA 11000V / 433V Oil Filled Transformer OCTC SUPPLY : Suppy of 3 phase Oil immersed oil natural air natural (ONAN) type indoor transformer - 500 KVA, 11000V / 433V, Dyn 11, Power 500KVA ( as per IS 1180 AMENDMENT No. 4, 2021 ) off circuit tap 6 Step / 7 position i.e. @2.5% , +5% to -10%, Transformer shall be double wound, core type with low loss, non ageing, high permiability PRIME GRADE, CRGO with M4 Grade or Better, perfectly. Insulated and clamped to minimizenoise and vibrations. Transformer shall be of BOLTLESS core design & core shall be purchased directly from Manufacturer from their accredidted organization. Winding shall be made with 99.9% pure electrolytic grade copper insulated with high grade paper insulation. Manufacturer shall provide followings for LV coils so as to reducethe stray loss and overall surface area.The HV & LV winding should be able withstand thermal and mechanical stress in te event of short circuit. Transformer oil shall be as per IS-335 : 1993. It shall be \\"PCB free and polycyclic Aromatic Hydrocarbons free minarel oil \\" The material safety Data sheets (MSDS) for the transformer oil shall be submitted by the bidder along with the offer. The tank together with radiator, conservator, bushings and other fittings shall be designed to withstand without permanent distortion the following conditions. |
| 8 | a) Full vacume of 760 mm of Hg. For filling with oil by vacum. b) Internal gas pressure of 0.35 Kg/cm2 (5 lbs / sq. in) with oil atoperating level. Transformer shall be fitted with cable boxes / cable box with disconnecting chambers. The cable boxes shall be suitable for termination 3 runs of 300 sq.mm XLPE cable. All contacts for alarm, trip and indication circuits shall each be electrically free, wired for auxiliary D.C. supply as specified and brought out to seperate terminals at the terminal blocks in the marshalling box. Terminals shall be rated for rated for 10A wiring shall be with stranded, copper conductors of sizes not smaller than 1.5 sq.mm for control and 2.5 mm for C.T. circuits. C.T. terminals shall be provided with shorting facility. ( MAKE : CROMPTON GREAVES / ABB/ SCHNEIDER / VOLTAMP)KVA Rating - 500 KVA, No. of phase and rated frequency - 3-Phase, 50Hz, Rated Voltage (KV) - HV - 11 , LV - 0.433Connection - HV - Delta , LV - Star , Vector Group - Dyn 11Winding - HV - Copper , LV- CopperInsulation level (Impulse withstand) (KV peak)- HV-75,LV Insulation level (power frequency withstand) (kv rms) HV - 28, LV- 3,Tapping: Range - +5% to -10% @2.5% No. of steps - 6On HV - Yes, Tapping changer type - OCTC, Temparature rise of oil / winding over design ambient temparature of 50 Digree C - 50/55 (Digree C) Hot spot temparature rise over a maximum yearly weighted temparature of 32 Digree C, Voltmeter with selector switch (Digital) -1, Emergency meter EM 6400 (Class-0.5) -1Annunciation windows - 12, RELAY : Numerical O/C +E/F protection relay (in MODBUS) -1 (Type MiCOM P111L) Lock out relay (Master Trip relay) VAJH13 (86) - 1Auxiliary relay for Transformer Fault Indication (Type - VAA33) |
| 9 | Supply ,Installation,Testing,Commissioing of LT Panel with Allied work. Supply & delivery of cubical type L.T. Distribution panel board of required size to comprise the below mentioned components , base mounted compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 3 mm thick CRCA sheet steel with M/S angle frame. The panel board consisting of the following switches. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. |
| 10 | A) Incoming Arrangement.Supply and fixing in a separate chamber Microprocessor realeased based 50HZ, 415V 1600 Amp, Breaking capacity 50KA, EDO Drawout type ACB with IPR2 4 -pole -----including all accessories as directionof the EIC( Make L&T, Cat No.- SL96075 or equivalent cat of Legrand/Seimens or equivalent make as per approved by EIC)- 1 No. |
| 11 | B)Bus Section: 500V, 2000 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x85 mm x 10 mm + 1x85 mm x 10 mm] mounted on non-hygroscopic FRP/SMC/DMC insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. |
| 12 | C) Outgoing arrangement: a)Switch disconnector fuse (panel mounting cubical type) conform to IS : 13947 in o pen execution three pole & Neutral AC 23A, 50HZ, 415 Volt 400 Amp with 3 nos 400 Amp DIN type HBC fuse link (Make- L&T Cat No.- SK95481 or equivalent model of Legrand/Seimens or equivalent make as approved by EIC) ----- 04 nos , b) Switch disconnector fuse (panel mounting cubical type) conform to IS: 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 315 Amp with 3 nos 315 Amp DIN type HBC fuse link(Make- L&T Cat No.- SK95461 or equivalent model of Legrand/Seimens or equivalent make as approved by EIC)---8 nos c) Switch disconnector fuse (panel mounting cubical type) conform to IS: 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 250 Amp with 3 nos 250 Amp DIN type HBC fuse link (Make- L&T Cat No.- SK95642 or equivalent model of Legrand/Seimens or equivalent make as approved by EIC)---8 nos d) On load change over switch panel mounting front operated handle cubical type confrom to IS 13974 in open excution AC-23A 50 Hz 415 Volt 400 Amp 4 Pole change over switch (Make- L&T Cat No.- CO44000OOOO or equivalent model of Legrand/Seimens or equivalent make as approved by EIC) -------2 nos |
| 13 | Metering panel:(a) S& Fixing 0-500 V. Voltmeter of size 96 sq. mm. (square type) AE make - 1 set(b) S& Fixing 0-800 Amp. Ammeter of size 96 sq. mm. (square type) AE make.- 1 set (c) S& F Rotary type Voltmeter selector Switch of 10 Amp. KayCee make - 1 set (d) S&F Rotary type Amp. Meter selector Switch of 10 Amp. KayCee make -1 set (e) S&F current transformer of size 800/5A Kappa make ......3 nos (f) S&F 20 Amp. Bakelite fuses base & bridge with 4 Amp. HRC fuse link .GE make Phase & Nutral indicator ----4 Nos (g) Phase & Nutral indicator ----4 Nos. (h) S&F Danger board |
| 14 | Inter Connection:All interconnection of switches & bus bar Shall be made with suitable size copper bar to be kept for Cable connection for main switches & Change over & the end of all connections Of metering panel to be finish with Copper socket by crimping method having Marked ferrule for indication as per direction EIC. |
| 15 | Earthing.A separate earth bolts/Bars – 2 Nos will be provided in panel board in both sides as per drawing. |
| 16 | Cable Alley:Cable entry arrangement will be provided in the cubical panel in vertical position of appropriat size or each outgoing main switches & gland plate must be placed at the bottom or top of the panel with detachable type as per direction of E.I.C. |
| 17 | Painting.The complete panel board shall be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. |
| 18 | Constructural Details:All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & all Switches shall be fixed by M.S. nuts & bolts On angle /flat iron frame base.as per direction of E.I.C. |
| 19 | Installation of L.T Panel , incl carrage within a lead of 30mtr by placing in position, assembling living up, leveling and fixing on the floor, fitting & checking all component , correctly set according to requirement as directed by EIC |
| 20 | Providing massonery trench /box type 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning,including with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) withstone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) with suitable size appx 1200 mm width and appx 1000 mm depth (below the Ground level ) as per requirement at the condition of site & to complete the same direction of EIC [ HT Panel room- , Tr Room , LT Room ] |
| 21 | Supply and Delivery 11kV grade 3 core 240sq. mm HT XLPE AI-Armoured cable as per GS Make-RR cable/ Glowster/ Mescabe/Polycab (from HT Gear to Transformer) |
| 22 | Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonary trench incl. taking out RC covers,setting them in order,mending good the damages filling the trench with fine dry sand incl. supplying sand. |
| 23 | Making termination joint of above 11KV (earth) grade 3 core 240 sqmm XLPE Al cable incl. Supply of jointing kit (make -- Raychem) |
| 24 | Supply and delivery of 1.1KV grade 2 nos 4 c X 300 sq mm XLPE insulated armoured cable(L.T) as per GS Make-RR cable/ Glowster/ Mescabe/Polycab (from Transformer to LT Panel) [2 nos cable in parallal run for each connection] |
| 25 | Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonary trench incl. taking out RC covers,setting them in order,mending good the damages filling the trench with fine dry sand incl. supplying sand. |
| 26 | Supply and delivery of 1.1KV grade 1 c X 4 Run, 300 sq mm XLPE insulated armoured cable(L.T) as per GS Make-RR cable/ Glowster/ Mescabe/Polycab (from LT Panel to sub panel) |
| 27 | Supply and delivery of 1.1KV grade 1 c X 4 Run, 185 sq mm XLPE insulated armoured cable(L.T) as per GS Make-RR cable/ Glowster/ Mescabe/Polycab (from LT Panel to sub panel) |
| 28 | Supply and delivery of 1.1KV grade 4 c X 185 sq mm XLPE insulated armoured cable(L.T) as per GS Make-RR cable/ Glowster/ Mescabe/Polycab (from LT Panel to sub panel) |
| 29 | Laying of 4 (Four) No. cable upto 35 sqmm and upto 185 sqmm in underground trench 620 mm wide x 950 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 30 | Laying of 4 (Four) nos cable above 185 sqmm in an underground trench in single tier formation (horizontal) the trench size : 1220 mm x 1013 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed |
| 31 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 1 core 300 sqmm |
| 32 | 1 core 185 sqmm |
| 33 | Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials:1 core 300 sqmm |
| 34 | 1 core 185 sqmm |
| 35 | S&L of 4 core 2.5sqmm. Copper armoured cable (make-Havells/Finolex) in existing open mesonary trench incl. clamping and dressing from HT VCB contol circuit to transformer and from L.T. bus( For control circuit of over temp relay ) |
| 36 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :a. 4 core 2.5sqmm. Copper armoured cable |
| 37 | Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials:a. 4 core 2.5sqmm. Copper armoured cable |
| 38 | Supplying and fixing 415V, 415 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating [Make- L&T ,Siemens] |
| 39 | Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. |
| 40 | E. I work for Sub-station building SITC of 3kVA (1P-1P) UPS systems with SMF batteries for 30 mins back up (1 Phase Input & 1 Phase Output - Conventional type ) , inbuilt isolation transformer , Open battery rack & Battery interconnecting cable including SITC of 12 volt 42 Ah VRLA (Valve Regulated Lead Acid) SMF (Sealed Maintenance-Free) battery with flame and Fire retardant container conforming to UL-94 V0 grade with 02 (Two) Years warranty from the date of installation. UPS Make : Neumeric Onfiniti+/ equivalent model of APC/Vertiv.Battery Details : 6 Nos 12V / 42AH for each ( Total VAH 3024)Battery Make : SMF type Exide NXT+ or equivalent model of Amara Raja ( Quanta) /as per direction of EIC] |
| 41 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachme.Make-Legrand/ Schneider/ Crabtree/Seimens/ABB. 8 way |
| 42 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Make- Legrand/Schneider/Crabtree/Seimens/ABB. 2+10 way |
| 43 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 100 Amp FP |
| 44 | 240 V, 40A DP |
| 45 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32 Amp SP MCB |
| 46 | Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. |
| 47 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 9 mtr |
| 48 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board |
| 49 | Supply & Fixing 240 V, (1x 6A +1x 20A) Piano key type switch and (1x 6A +1x 20A) socket (Brand approved by EIC) on sheet metal switch board. with Supplying & Fixing 200 mm x 150 mm x 65 mm CRC sheet metal (16 SWG) Switch Board of the following sizes complete with three no.suitable size Copper bar with holes (for Ph, N & E) fixed onbakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) topcover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. |
| 50 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC. (Make- KEI/havells/Gloster) |
| 51 | 2x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 52 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 53 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5sqmm |
| 54 | 4 sqmm |
| 55 | 6 sqmm |
| 56 | Supply and delivery of 250 V 50 HZ high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/Orient/Approved) 18\\" (450 mm) |
| 57 | Fixing of high flo oscillating type metal body Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC |
| 58 | Supply,240volt, 230mm(9\\") sweep, 920 rpm heavy duty exhaust fan with all accessories (Make - Havells/EPC/ Crompton as per EIC) |
| 59 | Supply,240volt, 300mm(12') sweep, 920 rpm heavy duty exhaust fan with all accessories (Make - Havells/EPC/ Crompton as per EIC) |
| 60 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of diameter 30cm(9\\") |
| 61 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of diameter 30cm(12\\") |
| 62 | Supply & Fixing louver shutter on wall with necy. bolts & nuts . (6 mm dia x 62 mm long) aluminium 30cm exhaust fan (12\\" ) |
| 63 | Supply only 240V, 10 watt pressure die cast aluminium housing LED bulkhead for multiple application.(Make- Havells/Crompton/ Philips as per EIC)( Crompton Cat No.-LBHE-10-CDL) |
| 64 | Fixing only bulkhead ceiling fittings on wall/ ceiling by screwa etc |
| 65 | Supply only 240V, 50Hz, 100lumen per watt, 6500K/cool white 9 watt LED bulb. (Make-Havells/Crompton/Jaguar as per EIC) |
| 66 | Supply and delivery of Single LED batten with 01 nos LED polycarbonate T8 tube(20Watt, 230VAC, 50hZ,100lm/w) with all accessories. [Make: PHILIPS, CROMPTON, BAJAJ (Cat ref: IGP161LT8-16 1xT8 & LTB-20-865) |
| 67 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length |
| 68 | Supply and Delivery of LED Street Light(230V AC,70 w ,5500K,IP 66,THD<10%,bult in 2.5KV SPD) with all necessary connection.(Item code-CRP-421-70-57-SL-LM-NBK) [Make:Philips,Crompton,Bajaj as per EIC.] |
| 69 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 70 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 71 | Supply & delivery of 7 Mtr. HDG Octagonal Poles in 3mm shaft thickness in MS Condition before Galvanization with Top A/F 70 mm, Bottom A/F 135 mm, Base Plate 225x225x16 mm suitable for wind speed 180 Km/hr. as per IS:875 and 4 Nos. M20x600 “J” Type Foundation Bolts as per EN-8 (Min UTS-600) & Anti-theft locking door arrangement for safety of MCBs, Terminal etc.A) Material grade of shaft shall be of S355JO/JR as per BSEN 10025 or Equivalent IS: 2062 grade E350 (BR)B) Materials grade of Base Plate shall be E250(BR) as per IS:2062C) Galvanization as per BSEN ISO:1461D) Fusion Welding as per ISO 3824-2:2021 (Make –Transrail/ Valmont/Bajaj) |
| 72 | Construction of suitable Shallow foundation upto 10mtr. Octagonal Pole with M-20 grade concrete for Pole considering soil bearing capacity (SBC) 10T/sq. mtr. at 2 Mtr. depth with all materials and labour payment made as per PWD civil schedule & as per direction of EIC. Erection of Pole by using of lifting equipment like hydra etc. and fixing offoundation bolts , anchor plate etc. with necessary arrangement ,Testing commissioning of all electrical equipment of Pole like led fixtures, Bracket, MCBs Terminal etc. with necessary connection |
| 73 | 1500 mm HDG Single Arm Bracket made of (48.3 ODx2.9 thik.) Mild Steel Pipe as per IS:1161 suitable to insert at Pole Top A/F 70 |
| 74 | Supply & delivery of 90 W Led Street Light Lumen Efficacy >120, CRI>70, CCT-5700K, IP- 66, Aluminum Dia Cast Housing, with Toughened Glass ,Potted driver. In build Surge Protection 4kv Internal & 10 kv external LM 79 Report shall be provided from manufactures, LM 80 - Nichia/ Osram/ Lumiled/ Seoul/ Bridge Lux –5 Years Warranty (Make- Crompton Model CRP-411-90-57-SL-GL-NSG/ Similar type model of Bajaj/ Philips/ Surya/ Transrail) |
| 75 | Supplying and fixing Timer panel Enclosure The Box should comprising following accessorise.A) 230 V , 50 Hz ,16 AmpSingle dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartzdriven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 noB) 32 A DP Power conctractor ( Make - Legrand / L & T MNX 22-2P ) – 1 noC) DP MCB 32 Amp ( L & T / Ligrand ) - 1 noD) Auto /Manual By pass Toggle Switch arrangement – 1 no.E) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T ) – 1 noF) Bakelite basewith suitable bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light fitting fittings) |
| 76 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil |
| 77 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe |
| 78 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 79 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 80 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 4 SWG |
| 81 | Supply and delivery of 3 Core 1.5 Sq.mm Copper unarmoured cable. Connection from Pole to light fittings Make: (Mescab/Gloster/ Polycab/ KEI). |
| 82 | Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar/ KEI/ approved ) as per direction of EIC. 4 core 35sqmm ( From VTPN to HTPN DB ) |
| 83 | 2 core 10 sqmm (For compound light) |
| 84 | Laying of cable as below, after cutting floor/ pavement/ wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. 4 core 35sqmm |
| 85 | 2 core 10 sqmm |
| 86 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed 2 core 10 sqmm |
| 87 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 4 core 35sqmm |
| 88 | 2 core 10 sqmm |
| 89 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 core 35sqmm |
| 90 | 2 core 10 sqmm |
| 91 | Earthing with 80mm dia G.I. pipe(TATA-M) X 3.0 mtr. Long and 1X19/8 stranded GI(hot dip) wire(4mtr. Long), 25 mm. dia X 150mm long galvanized bolt,double nuts,double washers incl. socketing at both ends of stranded GI(hot dip) wire by crimping socket/thimbles and S&F 40mm dia GI pipe(ISI-M) protection(3mtr. long) to be filled with bitumenpartly unde the ground level and partly above ground level to an average depth of 3.65mtr(For morrum soil) as per GS {vide page no G-1, item no - 2.c.}(2 nos for transformer, 2 nos for H.T.Panel and 2 nos for LT panel) |
| 92 | Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode (For Transfomer Neutral) |
| 93 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Morrum Soil |
| 94 | Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36X86.36cm X 46cm deep(below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter(inside) CI hinged inspection cover of size 36.56 cm X 35.56 cm wit hlocking arrangement GI reducer incl. drilling of 46 Nos. 12mm dia hole on GI pipe asto GS |
| 95 | Extra for treatment of soil by using salt & charcoal or coke for pipe electrode(for morrum soil) as per GS |
| 96 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65mmX8mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required double earth busbar with interconnection at regular interval should be provided as per GS. |
| 97 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50mmX6mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required for connecting the equipments body to earth busar & earth electrode to earth busbar as per GS |
| 98 | Supplying & laying of 1X50sqmm single core XLPE, unarmoured and stranded copper cable for connecting neutral bushing of transformer to the neutral busbar incl. appropriate copper socket and nuts & bolts as per direction of EIC (2 Runx14mtr) |
| 99 | Supply & delivery of Single phase /50Hz/230 Volt Hi-Wall Split Air Conditioner having following specification :- 1) Cooling Capacity Nominal (BTU/Hr) - 18000. 2) Minimum ISEER rating - 3.5, 3) Refrigerenr - R410/R32. 4) Compressor - Rotary/Scroll. 5) Evaporator & Condenser Coil - Copper. 6) Operating Outdoor Temperature = 50 degree C and above. 7) Power Supply - 230V, 50Hz (+ Tolerrance as per applicable standard). 8) Minimum Room Discharge Air Flow rate - 600CFM. 9) Cordless Remote Arrangement with all modernized provision to temperature setting, fan speed option (Low/Medium/High) Auto Swing. (Make- O-General/ Mitsubishi Electric/ Mitsibishi Heavy) |
| 100 | Installation, testing & commissioning of the above-said split ACs incl. supply & fixing required Angle Iron Structure on wall for placing outdoor unit & mending good the damages as per direction of E.I.C. |
| 101 | Supply & Installation of Extra Add-on items- HVAC grade 5/8\\"(for suction) & 1/4\\"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. |
| 102 | Supply & Laying 19 mm dia heavy type PVC pipe for water drainage. |
| 103 | Supply & Laying 4 core 2.5 sqmm PVC insulated & unarmoured Copper Cable (Make- KEI/Gloster/Finolex) for 2/1.5 Tr. Split A.C Machine. |
| 104 | Supply & fixing automatic single phase AC starter of 25Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.- OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed surface enclosure as to G.S. Including S&F of 4 Module surface mounting enclosure box (Crabtree/Legrand/Havells). |
| 105 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 106 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 107 | LC Work Supply & Fixing Lightning conductor Air-terminals made of 15 mm dia1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 108 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: Length upto 0.5 Mtr |
| 109 | Length above 0.5 Mtr |
| 110 | Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. |
| 111 | Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. |
| 112 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. |
| 113 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. |
| 114 | Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work. |
| 115 | Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. |
| 116 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil. |
| 117 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long),13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (For Morrum Soil By ISI-Medium GI pipe as to GS. |
| 118 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS. |
| 119 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 120 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 121 | Electrical Safety Equipments Supplying 11KV grade rubber Gloves |
| 122 | Supply & Delivery of 1800mmX900mmX 12mm thick rubber mat of approved quality (ISI certified) suitable for11KV system |
| 123 | Supply & Fixing 200mmX300mm EI danger board for 11KV/415V system |
| 124 | Supply & Fixing First Aid box of best quality with all medicine/ normal contents as per direction of EIC |
| 125 | Supply & Fixing shock treatment chart pasted on best quality water proof ply board / on hard board with wooden frame and glass cover as per direction of EIC |
| 126 | Supply & Fixing 5 Kg capacity ABC stored pressure type Fire Extinguisher with discharge horse & nozzle on wall with suitable iron bracket incl. all accessories as per direction of EIC (make-- Fire Shield/Fire Safe) |
| 127 | Supply & Fixing 9 Litre capacity round bottom GI Fire bucket with iron hooks complete with painting interside white & outer side red with lettering the word \\"FIRE\\" in black colour complete with sand filling as per direction of EIC |
| 128 | Testing of total system comprising of different sub-station equipments incl. all protective devices and relays with overload and earth fault condition at site by own testing equipments and tools & plants by authorized firm of Directorate of Electricity and submitting the testing report to DOE.Finally charging & commissioning the entire system after obtaining approval from the Directorate of Electricity |
| 129 | Submission of a sub-station drawing showing HT & LT cable ducts, single line power diagram, EI layout, Earthing system (i.e. equipment & neutral earthing) etc. with elevation and plan as per direction of EIC and as per requirement of DOE |
| 130 | FIRE ALARMING AND DETECTION SYSTEM SITC of Microprocessor based addressable type fire alarm control panel. The Fire Alarm Panel shall have single loop and relay controls. And Also (UL/EN/LPCB/VDS approved), The PANEL shall be able to generate History Events. The panel should be capable to acknowledge, singnal silence and reset function of event. The Panel shall have provision for Modbus/Bacnet/Lanworks.Display should be minimum 80 chacrecteor LCD, UL/EN (Approved Makes : GST – GST200N-1 Intelligent Fire Alarm Panel/Secutron/Mircom). |
| 131 | SITC Addressable Multicriteria detector with base for smoke and heat sensing . UL/EN approved make. (Approved Makes : GST/Secutron/ Mircom). |
| 132 | SITC of Addressable Manual call point for manual Fire signaling UL/EN approved.(Approved Makes : (Approved Makes: GST/Secutron/Mircom). |
| 133 | SITC of Addressable Combined Sounder and Strobe with programmable alarm tones and with require modules. UL/EN approved. (Approved Makes : (Approved Makes : GST/Secutron/Mircom). |
| 134 | S & laying of 2Cx 1.5 Sq. mm Twisted copper FRLS , Cable fixed on the surface/ through conduit of the building structure complete with termination and testing as per requirement. Approve Make : POLYCAB/ HEMFLEX/MESCAB/KEI. |
| 135 | S& laying of 25 mm PVC conduits including cost of junction boxes, bends, elbows sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. Approve Make : AKG/Norpac/Primco Plast/BEC/ or any ISI. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail