| 1 | PUMPSET |
| 2 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 3 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 5 | OD512233/2025-2026:Supply and providing 40mm/ 50 mm/nearest stainless steel Hose Collar with Hose Clip |
| 6 | OD512234/2025-2026:Supply and connect 40mm/ 50 mm/nearest HDPE pipe ISI (10kgf/cm2) to the existing pump set and as a delivery pipe with suitable connectors. |
| 7 | OD512236/2025-2026:Supply and fixing flat iron clamps made from 40mm/ 50 mm/nearest flat iron clamp with suitable size bolt and nut forfixing delivery pipe on the top of the well as required. |
| 8 | OD512237/2025-2026: Supply and providing 40mm/ 50 mm/nearest dia or nearest size G.M Nonreturn valve (ISI) |
| 9 | OD512228/2025-2026:Supply and fix 40mm/ 50 mm/nearest GI flange with the required bolt, nut, washer, and gasket. etc. |
| 10 | OD512235/2025-2026:Supply and installation testing and commissioning of 2HP Borwell submersible motor pump set having 2850 RPM suitable for single phase 230/240V, 50 Hz, AC supply conforms to relevant ISS. Head 66 to 121m with a flow rate of 4000 to1000 LPH and should provide 3000LPH at a head of 110m with standard size delivery pipe connected to the motor using leakproof materials as required including giving connection to the existing pipe as per the direction of the engineer. (Kirloskar/Texmo/Crompton or equivalent) |
| 11 | 90.14.28.13:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL) |
| 12 | OD512232/2025-2026:Supply and laying of 20mm or nearest size Nylon rope |
| 13 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 14 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | 2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole and netural |
| 16 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 17 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 18 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 19 | OD512238/2025-2026:Supply and installation of dust and vermin proof Three-phase Sintex Meter Board (GS MB6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing iton the wall, making good the damages, color washing, etc. as required |
| 20 | OD512231/2025-2026:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board |
| 21 | OD512227/2025-2026:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board |
| 22 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 24 | OD512230/2025-2026:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate |
| 25 | OD512229/2025-2026:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system Please Enable Macros to View BoQ information |