| 1 | Electrical Maintenance work |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.15.1:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A |
| 5 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 6 | 90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point |
| 7 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 8 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 9 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 10 | OD523867/2025-2026:Supply and providing 230 V, 7/9W, LED retrofit bulb, E-27, 100L/W, in the existing holder/bracket fittings /post top/gate lamp etc as required. |
| 11 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 12 | OD523864/2025-2026:Supply and providing 230V, 36/40 watts, 4 feet, polycarbonate, integrated electronic driver, minimum 4000 lumen out put, batten LED tube light fittings directly on wall/ceiling with screws/ nut bolts and giving connections with 3 core flexible copper wire etc as required. (Crompton Linea/ Havells Lumiline/ Luker Lumos 40 DT/ equivalent Philips/Bajaj make) |
| 13 | OD523848/2025-2026:Supply and providing 230V, 22 watts, 4 feet, polycarbonate, integrated electronic driver, batten LED tube light fittings directly on wall/ceiling with screws/ nut bolts and giving connections with 3 core flexible copper wire etc as required. |
| 14 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 15 | 90.4.3:Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required. |
| 16 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 17 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 18 | OD523866/2025-2026:Supply and providing 200/225 mm sweep exhaust fan in metal frame and leaf, working on 230V single phase AC with bird guard, corrosion resistant powder coated/painted, fixing on wall in the existing opening with necessary anchor bolts, nuts, washer etc including giving connections with 3 core wire etc as required. |
| 19 | OD523872/2025-2026:Supply and providing 230V, 6 W, LED spot light fittings on wall / ceiling and giving connections etc as required. (Crompton CDR or equivalent make). |
| 20 | OD523870/2025-2026:Supply and providing 5 W, LED batten tube mirror lamp fittings on wall/ceiling and givingconnections with required length of 16/0.20 mm PVC insulated and sheathed 3 core roundcopper conductor flex wire etc as required. |
| 21 | OD523871/2025-2026:Supply and providing 240V, 400 mm, 16 inch, energy efficient, Heavy duty, pedestal fan with 3 speed setting, 90 degree oscillation, adjustable fan height and tilt, and giving connection etc at site as required . (Almonard / Crompton/ Bajaj/ Usha or equivalent reputed make) |
| 22 | OD523849/2025-2026:Supply and providing 240V, 450 mm, 18 inch, energy efficient, Heavy duty, wall mounting fan with 3 speed setting, oscillation, adjustable/tilting, fixing on wall and giving connection etc as required . (Almonard/Crompton high speed torpido or equivalent reputed make) |
| 23 | OD523858/2025-2026:Supply and providing 240V, 400 mm, 16 inch, energy efficient, wall mounting fan with standard accessories, 3 speed setting, oscillation, adjustable/tilting, fixing on wall and giving connection, testing etc as required . (Almonard/Crompton/Bajaj/Usha/Havells or equivalent reputed make) |
| 24 | OD523860/2025-2026:Supply and providing 250 V, 25/32A, HRC fuse link in the existing fuse carrier/ switch unit and giving connections etc as required. |
| 25 | OD523865/2025-2026:Supply and providing 12V, heavy duty, 25/30 Amps or nearest size LED strip driver unit, fixing in control box and giving connections etc as required. |
| 26 | OD523859/2025-2026:Supply and providing 12V, 14/12 watt/meter or nearest size, LED profile strip light (5mtr roll length) fixing through the cove on false ceiling with connector, end cap, double sided adhesive form tape and giving connections etc as required. |
| 27 | OD523862/2025-2026:Supply and providing 18 W, LED out door bulk head fittings on wall/ceiling and givingconnections with required length of 16/0.20 mm PVC insulated and sheathed 3 core roundcopper conductor flex wire etc as required. (LBKOVSL18 or equivalent make) |
| 28 | OD523855/2025-2026:Supply and providing 230V, 24/26 watts, recess mounting LED down light with heat sink and PC diffuser, integral high efficiency driver, pressure die-cast aluminum heat sink, powder coated finish THD less than 10%, minimum 100L/watt, cutting hole on false ceiling, fixing and giving connections etc as required. (Havells Integra Neo, K-Lite Diva7, Crompton, Keslec, Philips make) |
| 29 | OD523854/2025-2026:Supply and providing 230V, 18 watts, recess mounting, integral high efficiency driver, LED down light with heat sink and PC diffuser, powder coated finish THD less than 10%, minimum 100L/watt, cutting hole on false ceiling, fixing and giving connections etc as required. (Havells, Crompton, K-Lite, Philips make) |
| 30 | OD523863/2025-2026:Supply and providing 230V, 15 watts, recess mounting, LED down light with heat sink and PC diffuser, integral high efficiency driver, powder coated finish THD less than 10%, minimum 100L/watt, cutting hole on false ceiling, fixing and giving connections etc as required. (Havells, Crompton, K-Lite, Philips make) |
| 31 | OD523850/2025-2026:Supply and providing 230V, 12 watts, recess mounting, LED down light with heat sink and PC diffuser, integral high efficiency driver, powder coated finish THD less than 10%, minimum 100L/watt, cutting hole on false ceiling, fixing and giving connections etc as required. (Havells, Crompton, K-Lite, Philips make) |
| 32 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 33 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 34 | 90.5.1.5:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.DC operated remote controlled electric bell |
| 35 | 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 36 | OD523856/2025-2026:Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required, 1 run of Cable (Finolex/D-Link/Schneider/RR) |
| 37 | 1.18.1:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair |
| 38 | OD523861/2025-2026:Supply and providing RJ45 CAT6 pass through connector ends ethernet cable crimp connectors, UTP net work plug, LAN Crimp and making connection with crimping and testing etc as required. |
| 39 | OD523846/2025-2026:Supply and providing modular RJ 45 socket outlet suitable for CAT6E LAN with suitable modular PVC Gang box plus face plate (combo) fixing on wall/ceiling and giving connections etc as required (D-Link, TP Link/ Havells/CP plus) |
| 40 | OD523847/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 1.0 sq. mm |
| 41 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 42 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 43 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 44 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 45 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 46 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 47 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 48 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 49 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 50 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 51 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 52 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 53 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 54 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 55 | OD523857/2025-2026:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, single door. |
| 56 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 57 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 58 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 59 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 60 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 61 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 62 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 63 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 64 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 65 | OD523845/2025-2026:Supply and providing 4 pole PVC/SMC enclosure with mounting rail for independent mounting of MCB/ RCCB/ Isolator /timer etc, fixing on panel/wall as required. |
| 66 | OD523852/2025-2026:Supply and providing dust and vermin proof, wall mounting, Hot press moulded SMC Cable junction Box of following sizes suitable for cable termination, knock out for cable entry and exit, including 32 Amps 4way connector terminal, 200x140x95 mm or nearest size. (Sintex GS-JB2014 or equivalent make). |
| 67 | OD523878/2025-2026:Labour Charges for periodical maintenance and servicing of 1TR/ 1.5TR/2TR, 240/415V high wall Split type Air Conditioner Units including all routine and preventive maintenance, rectifying petty defects if any (excluding the cost of spare). Complete cleaning and servicing of IDU and ODU. water servicing using chemicals, water pump etc. and. Air servicing using cleaning materials and pressure air pump etc. Checking gas leakage/pressure, cooling performance and normal working of the Air conditioner Units as required. |
| 68 | OD523853/2025-2026:Labour Charges for periodical maintenance and servicing of 4TR/ 5TR , 415V Tower type, Split Air Conditioner Units/ceiling mounted casset type AC unit, including all routine and preventive maintenance, rectifying petty defects if any (excluding the cost of spare). Complete cleaning and servicing of IDU and ODU. water servicing using chemicals, water pump etc. and. Air servicing using cleaning materials and pressure air pump etc. Checking gas leakage/pressure, cooling performance and normal working of the Air conditioner Units as required. |
| 69 | OD523886/2025-2026:Supply and filling sufficient quantity of freon 22/32/410 A refrigerant gas for existing air conditioner unit including leak testing rectifying the defects leak arresting, brazing and make the compressor in good working condition for the following.1TR/1.5TR/2TR. split AC unit |
| 70 | OD523880/2025-2026:Supply and installation of 2 pole power contactors 18/22A AC3 suitable for1TR/1.5TR/2TR A/C unit in the place of defective one and giving connection etc as required. |
| 71 | OD523888/2025-2026:Supply and renewing temperature sensor suitable for indoor unit of 1TR/1.5TR/2TR in place defective one. |
| 72 | OD523884/2025-2026:Supply and renewing 2.5/4 mfd capacitor suitable for out door fan motor of 1TR/1.5TR/2TR in the place defective one. |
| 73 | OD523887/2025-2026:Supply and renewing 36/40 mfd capacitor suitable for compressor unit of 1TR/1.5TR/2TR in place defective one. |
| 74 | OD523883/2025-2026:Supply of remote control unit for Single phase 1 TR/ 1.5 TR/2TR/3TR (Bluestar/Voltas/ Daikin/equivalent ) Wall mounting split A/C unit. |
| 75 | OD523879/2025-2026:Supply and renewing copper/brass flare nut suitable for out door/indoor unit of 1TR/1.5TR/2TR in place defective one. |
| 76 | OD523873/2025-2026: Supply, Installation, Testing and Commissioning of Refrigerant Piping with 3/8 " and 5/8 " (9.5 /15MM) Hard / soft drawn Copper tube of suitable sizes (22swg) , with copper connector, elbow, tees, Tubular Nitrile Insulations and covering with white fiber tape etc. as required. |
| 77 | OD523882/2025-2026:Dismantling the defective PCB, rectify the defect, replacing damaged components, testing re-install the same and make the unit in perfect working condition. :- 1TR/1,5TR/2TR |
| 78 | OD523868/2025-2026:Labour Charges for repair/maintenance and servicing printed circuit board of inverter type split AC Unit in electronic work shop (high wall/tower type) including replacing of damaged electronic spares and conveyance charges, preventive maintenance, rectifying petty defects if any, re-fixing the same testing and trial run etc as required. |
| 79 | OD523881/2025-2026:Supply and providing 10 mm thick nitrile/rubber form for insulating the refrigerant pipes and over lapping the whole with fire/polyester/tuflon white tape as required. |
| 80 | OD523885/2025-2026:Supply and providing Voltage stabilizer (4 KVA) suitable for 1.5/2.0 TR split AC unit with input 170 to 270 volts, output 210 to 230 volts, over load cut off, time delay, indicators etc as required (v-guard or reputed equivalent make) |
| 81 | OD523851/2025-2026:Supply and providing Voltage stabilizer (3 KVA) suitable for 1.0 TR split AC unit with input 170 to 270 volts, output 210 to 230 volts, over load cut off, time delay, indicators etc as required (v-guard or reputed equivalent make) |
| 82 | OD523876/2025-2026:Supply, installation, testing and commissioning of single phase, inverter type, wall mounting, 1.5 TR, 5 star, split air conditioner unit with hermetically sealed compressor, using non CFC refrigerant, conforming to IS1391 part III, suitable for operating on 230 V, 50Hz AC supply, performing cooling, dehumidifying, air circulating, filtering, high energy efficiency, copper condensing coil, cordless remote control, white/off white including insulated copper pipe connection and control cable from indoor to outdoor unit and drain pipe etc up to 3 mtrs, etc. with 3 nos free service in one year, Daikin / Voltas / Blue Star/Lloyd/Panasonic/LG make) |
| 83 | OD523877/2025-2026:Supply, installation, testing and commissioning of single phase, inverter type, wall mounting, 2.0 TR, 5 star, split air conditioner unit with hermetically sealed compressor, using non CFC refrigerant, conforming to IS1391 part III, suitable for operating on 230 V, 50Hz AC supply, performing cooling, dehumidifying, air circulating, filtering, high energy efficiency, copper condensing coil, cordless remote control, white/off white including insulated copper pipe connection and control cable from indoor to outdoor unit and drain pipe etc up to 3 mtrs, etc. with 3 nos free service in one year, Daikin /O-General / Blue Star/Lloyd/Panasonic/LG make) |
| 84 | OD523874/2025-2026:Supply and providing heavy duty powder coated wall bracket for mounting out door unit of split AC as required. |
| 85 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 86 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 87 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm |
| 88 | OD523889/2025-2026:Supply and providing 20 mm dia, ISI marked PVC conduit for drainage of indoor unit as required. |
| 89 | OD523875/2025-2026:Supplying and providing UPS, tubular, lead acid battery, 100AH, 12V, with minimum 3 years warranty, replacing the old one and giving connections for existing UPS etc as required. (Excide 6EL100, C-10 or equivalent reputed make) |
| 90 | OD523869/2025-2026:Labour Charges for providing one electrician/technician with a helper for attending urgent repair work/ fault finding and rectifying, against shutdown or complaint in electrical installation, electronic equipment or AC units with tools, step ladder, safety equipment, and measuring instruments as required. Please Enable Macros to View BoQ information |