| 1 | Servicing of existing installed WTAC/STAC of 1.5 TR & 2.0 TR capacity AC and water coolers including cleaning of water tank, checking of unit, greasing, oiling etc. i/c chemical cleaning of condensing & cooling coil with high pressure pump and cleaning of tank of water cooler, changing the air filter, checked & tightening all electric connections, testing the machine etc. as reqd. |
| 2 | Supply & Charging R-22/410/407/32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolers i/c pressure testing, flushing the system and Gas Charging complete as reqd. |
| 3 | Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd. |
| 4 | Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd. |
| 5 | Providing and fixing of 4 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd. |
| 6 | Replacement of following capacity compressor in the existing WTAC/Split AC with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd. |
| 7 | 1.5 TR capacity |
| 8 | 2 TR capacity |
| 9 | Supplying and replacement of wornout/defective copper condensor coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd. |
| 10 | a) 1.5TR capacity |
| 11 | b) 2 TR capacity |
| 12 | Supplying and replacement of wornout/defective copper cooling coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd. |
| 13 | a) 1.5TR capacity |
| 14 | Repairing of inverter PCB in existing indoor/outdoor unit complete etc as reqd. |
| 15 | Supplying And Replacement of inverter PCB in existing indoor/outdoor unit complete Installation, Testing etc as reqd. |
| 16 | Supplying And Replacement of Fan Motor with fan Blade in existing WTAC/STAC of 1.5/2.0 TR unit AC i/c connection, Testing etc required. |
| 17 | Dismantling, shifting and reinstallating of existing 1.5TR/ 2.0TR capacity STAC (indoor and outdoor unit) including repairing the damaged caused due to dismantling within same office etc as required. |
| 18 | Comprehensive maintenance of WTAC/STAC unit and water cooler i/c cleaning of water tank, attending day to day complaints from 9 AM to 5 PM and rectifying the defects, replacement of worn out parts such starting / running capacitor, starting relays, overload relays, thermostate as selector switches, sleeves, knobs, Front grills connectors, PCB etc. which required to be replace during comprehensive maintenance & monthly cleaning of filters, condenser fan, blower, fan/blower motor, Coils, (Gas charging, compressor not covered under comprehensive maintenance) complete as per terms & condition and direction of Engineer-in-charge. (40 X 7 Months =280Nos) |
| 19 | Credit for dismantle material |
| 20 | a) Compressor 1.5TR/ 2TR |
| 21 | b) Refrigerant copper pipe / Cu wire with insulation |
| 22 | c) 4 core 2.5sqmm wire with insulation |
| 23 | d) PCB |
| 24 | e) Condenser coil |
| 25 | f) Cooling Coil Please Enable Macros to View BoQ information |