| 1 | Civil Works |
| 2 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 3 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 4 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | Electrical Works |
| 9 | Supply, installation, testing and commissioning of Outdoor Floor / Wall MountingCubical Type KSEBL Metering Panel with Double Door and Canopy suitable for 240V, Single Phase, 2 Wire 50 Hz AC supply system having sufficient front surface areafabricated in compartmentalized design from CRCA sheet steel of 2 mm thick forframe works and covers, 2 mm thick for gland plates, cleaning and finishing completewith 7 tank process for Powder Coating in approved shade and then provided withClear Coating, fabrication shall be done in transportable sections, entire panel shallhave a common copper earth bar of size 12 mm x 3 mm at the rear with 2 Nos. earthstud and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) orHRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductorcables, cable alleys etc. complete as required. The panel shall conform to the ElectricalInspectorate and KSEBL standards and it shall only be manufactured after gettingapproval from the Engineer-in-charge and the Consultant.INCOMER1 Nos - Provision for Fixing Single Phase Energy Meter1 Nos - 32A Bakelite Fuse Units with HRC Fuse of Suitable Rating1 Nos - 32A Neutral Link1 Nos - 16A/25A 10kA DP C Curve MCBThere shall be Separate Compartment for Energy Meter and Fuse Units/Neutral Linkwith KSEBL Sealing ProvisionSURGE PROTECTION DEVICE1 Nos - 2 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + Class II 50kA SPDon the Incoming / Outgoing Side of Incomer MCB along with Green and RedIndication Lamps with Control MCBs [The connections to Phase, Neutral and Earthshall be done using 16 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (HeatResistant Flame Retardant) PVC insulated single core copper conductor cables withless than 0.45m in length]OUTGOING1 Nos - Outdoor / Street Light Compartment with 6A/10A 10kA DP C Curve MCB,25A 30mA DP RCCB, 9A/12A TP AC3 Duty Contactor with Auxiliary Contacts,24Hour Digital Timer Switch, Auto - Manual Selector Switch (2 Pole 2 Way), ON(Red), OFF (Green) Push Buttons and ON (Red), OFF (Red) Indication lamps withControl MCBs |
| 10 | OD155537/2025-2026Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm baseplate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixedhead frame including round arm luminary carriage suitable to install 4/6 nosluminaries in symmetrical arrangement including connector foundation bolt 4 nosexisting RCC foundation and junction box etc, complete 8 Meters |
| 11 | OD155430/2025-2026installation, testing and commissioning of 200W LED Flood Light with 3Years Onsite Warranty having output greater than 105lumen/W 4000-6000 K with IP66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than0.95 at full load, internal surge protection up to 8 kV and Aluminium pressure die-castPowder coated housing, acrylic cover complete with THD less than 10%, power factorgreater than 0.98, RoHS compliant, duly wired up for use on 240V AC supply. Drivercompartment shall be separately accessible for maintenance (LM 79 and 80 certificatesfrom NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 13 | OD155432/2025-2026Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium powercable of 1.1 kV grade of the following sizes in the existing excavated trenches, built uptrenches and pulling through existing pipes including all minor civil works etc.complete as required2 Core 10 Sq.mm |
| 14 | 90.12.7.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps noted alongwith the cables, spacing of clamps not exceeding 60cms, making good the damages ,colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 15 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 16 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm) |
| 17 | OD155442/2025-2026Supply and providing gland earthing using Gland Earthing Clips / Clamps forfollowing size of PVC insulated and PVC sheathed / XLPE Aluminium conductorcable of 1.1 kV grade etc. complete as required2 X 10 Sq.mm |
| 18 | OD155439/2025-2026Excavation of all types of soils for the laying of PVC insulated and PVC sheathed /XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC /Conduit Pipes, Earthing conductors to the required width and depth up to andincluding 1.2m and back filling etc. complete as required. (The trench dimensions andspecifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBLStandards) |
| 19 | Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. with charcoal/ coke and salt) etc. complete as required |
| 20 | 90.16.1.11Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required4.06 mm GI conductor (8 SWG) |
| 21 | OD155433/2025-2026Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with allnecessary accessories and laying in existing excavated trenches, built up trenches,clamping in built up trenches / walls / MS supports using Stainless Steel saddles andscrews of which spacing between 30cm to 60cm including all minor civil works etc.complete as requiredUp to and including 40mm |
| 22 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC)pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection tounderground power cables with all required accessories in ground in the existingtrench50/38 mm or nearest size |
| 23 | OD155429/2025-2026Supply, fabrication and installation of Outdoor Floor / Wall Mounting Cubical TypeKSEBL Metering Panel / PVC Pipe / Cable supports / Name Board supports etc. usingMS Angles, Flats, C Channels and Square Tubes of adequate size painted with twocoats of epoxy primer and two coats of black / grey / other approved shade epoxypaint. The scope also the includes the supply and installation of necessary rectangular /square plates, anchor fasteners, bolts, nuts, round and spring washers or screws etc.complete as required |
| 24 | OD155436/2025-2026Preparation and submission of application for Single Phase Connection along withdrawings, detailed load schedule etc. and co-ordination with KSEBL for energizationetc. complete as required. (*All Statutory fees for getting connection shall also comewithin the scope of the Contractor) Please Enable Macros to View BoQ information |