| 1 | sitc of minimast lights |
| 2 | 90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm baseplate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixedhead frame including round arm luminary carriage suitable to install 4/6 nosluminaries in symmetrical arrangement including connector foundation bolt 4 nosexisting RCC foundation and junction box etc, complete 8 Meters |
| 3 | Conveyance, installation, testing and commissioning of 200W LED Flood lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABL accreditedThird party lab to be produced mentioning chip manufacturer) |
| 4 | 90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed650/1100VgradecopperconductorroundflexiblecablesconformingtoIS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 5 | 90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC)pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection tounderground power cables with all required accessories in ground in the existingtrench50/38 mm or nearest size |
| 6 | 90.12.10.2 Supply&layingofDWCpipeinordinarysoil0.75mbelowgroundlevel including excavation50/38 mm or nearest size |
| 7 | oD263391/2023-2024 Supply and fixing Timer Switch 24 Hours Programmable with IP 53cover (Leggrand Maxi Rex 4QTB or equivalent) |
| 8 | OD263392/2023-2024 Supply and fixing 3 pole AC 3 _ 32 A contactor |
| 9 | OD263393/2023-2024 Supply and Fixing 32 A, 2 Way neutral links mounted on DMC/SMC base |
| 10 | OD263394/2023-2024 Supply and fixing 32 A HRC Fuse Base with HRC Fuse link |
| 11 | 2.10.3 Supplying and fixing 5A to 32A rating, 240/415volts,10kA,\\"\\"C\\"\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcompletewithconnections,testingandcommissioningetc.asrequired. Double pole |
| 12 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 13 | OD263395/2023-2024 Supply & installation of Dust and Vermin Proof, Sintex Plastic Meter Board havingprovisiontofixKSEBmeter,Fuseunit,NeutralLink,Isolatoretc.asrequired including fixing it on wall, making good the damages, colour washing etc. as required. 650x350x210 |
| 14 | 90.14.5 Supplyandfabricationconveyanceandinstallationofangleironframeworkforwall mounting panel board |
| 15 | 5.1 EarthingwithG.I.earthpipe4.5metrelong,40mmdiaincludingaccessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 16 | 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 17 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/cablesandgivingconnectionasrequired3.15mmcopperconductor(10 SWG) |
| 18 | 90.16.5.3 Supplyofsuperiorqualitycopperearthsocketforthefollowingsizeofearth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 19 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 20 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 21 | 5.22.6 SteelreinforcementforR.C.Cworkincludingstraightening,cutting,bending,placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 22 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 23 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 24 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 25 | OD263495/2023-2024 Supply and fixing Name Board made of ACP on fourside with letters, framework as required. |
| 26 | OD263496/2023-2024 "OD45402/2022-2023. Supply and providing nameboard on 16/20mm thick granite slab with inscriptions as directed, fixing it on foundation with required materials etc. as required." |
| 27 | Connection charges - KSEB Please Enable Macros to View BoQ information |