| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 2 | P/L dry stone solling hand packed in foundation including all charges and plums.and for soak pit. |
| 3 | Providing and laying in position Cement concrete of specified grade (1:4:8) mix using Graded stone aggregate 20mm Nominal size including curing excluding cost of centering and shuttering etc complete all work upto plinth level. |
| 4 | Providing and laying in position Cement concrete of specified grade M10(1:3:6) mix using Graded stone aggregate 20mm Nominal size including curing excluding cost of centering and shuttering etc complete . |
| 5 | P/L 50mm thick cement concrete (1:2:4)mix DPC using crushed stone aggregates. |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :6.1.1 Cement lime mortar 1:1:6 ( 1 cement : 1 lime putty : 6fine sand)6.1.5 Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks above plinth level. |
| 8 | Formwork of ordinary timber planks for in situ concrete work and removal of the same. |
| 9 | Formwork of ordinary timber planks for in situ concrete work and removal of the same. |
| 10 | P/L reinforced cement concreteof specified grade (1:2:4)mix using crushed stone aggregates.including all carriages |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level5.22A.1 Mild steel and medium tensile steel bars |
| 12 | P/L 50mm thick cement concrete (1:2:4)mix Flooring using crushed stone aggregates. |
| 13 | Providing /applying 12mm thick cement sand plaster (1:4) mix |
| 14 | Providing and fixing Ist quality ceramic glazed wall tiles/ floor conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 15 | P/A wall putty of approved quality on plastered surface to make surface even smooth. |
| 16 | P/F M.S sheet Door with 35*35*5mm angle iron frame with shutter frame 25*25*5mm fixed with plain sheet.all necessary fittings complete including applying a priming coat complete job.(Doors/Windows). |
| 17 | P/F M.S sheet Door with 35*35*5mm angle iron doors,windows,ventilators with all necessary fittings complete including applying a priming coat complete job. |
| 18 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 19 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 20 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 21 | P/F B class prince PVC pipes 100mm complete job |
| 22 | P/F B class prince PVC pipes 75mm complete job |
| 23 | P/F of B Class/prince UPVC fittings fixtures of approved make 110mm complete job. |
| 24 | UPVC PLAIN BEND 75MM DIA. |
| 25 | UPVC DOOR BEND 100MM DIA |
| 26 | UPVC DOOR BEND 75MM DIA |
| 27 | PVC REDUCER 100MM*75MM |
| 28 | UPVC SINGLE EQUAL TEE(WITH DOOR)110*110*110MM |
| 29 | UPVC SINGLE EQUAL TEE(WITH DOOR)75*75*75MM |
| 30 | UPVC COLLAR 100MM DIA. |
| 31 | UPVC COLLAR 75MM DIA. |
| 32 | UPVC FLOOR TRAP 75MM*100MM DIA. |
| 33 | UPVC STAYS AND CLAMPSFOR PVC PIPES 100MM DIA. |
| 34 | UPVC STAYS AND CLAMPSFOR PVC PIPES 75MM DIA. |
| 35 | UPVC VENT PIPES 75MM DIA. |
| 36 | UPVC MANHOLE COVER 18*18(INCHES). |
| 37 | P/F G.I PIPES 15MM DIA.NOMINAL BORE COMPLETE JOB |
| 38 | P/F G.I UNION IN GI PIPE COMPLETE JOB 15MM NOMINAL BORE |
| 39 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 40 | P/F 15MM NOMINAL BORE CP BRASS BIB COCK OF APPROVED QUALITY |
| 41 | P/F15MM NOMINAL BORE CP BRASS STOP COCK OF APPROVED QUALITY |
| 42 | P/F 15MM NOMINAL BORE CP BRASS ANGLE VALVE FOR BASIN MIXER AND GEYSAR POINTS OF APPROVED QUALITY. |
| 43 | Add for electrification complete job |
| 44 | signboard Please Enable Macros to View BoQ information |