| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil :1 meter from cutting edge |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms. |
| 11 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 12 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mmangle iron and 3mm M.S. gusset plates at the junctions and corners, allnecessary fittings complete, including applying a priming coat of approvedsteel primer.Using M.S. angles 40x40x6mm for diagonal braces |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall ofmix:: 6 ( 1 cement : 6 coarse sand) |
| 14 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 15 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thicknessto be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4( 1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc., complete.In all colours, shades, except White, Ivory, Fume Red Brown |
| 16 | CERAMIC GLAZED TILESProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever required :White Vitreous China Angle back wash basin size 400x400 mmwith single 15 mm C.P. brass pillar tap |
| 18 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade.Two or more coats on new work |
| 19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 20 | Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls andfloors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 21 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.:Internal work-Exposed on wall 15 mm dia. nominal bore Light |
| 22 | Providing and fixing brass bib cock of approved quality.15 mm nominal bore |
| 23 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C waste fittings complete:Semi rigid pipe32 mm dia |
| 24 | Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 25 | Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipesconforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend |
| 26 | Electric wiring with 1.5 Sqm copper cable including 20mm dia 2 mm thick PVC Pipe 5 amp with socket box connection to the main pole completed as directed by the site engineer incharge |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 28 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed sand lead up to 40.00Km 1000mtr HL |
| 29 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed stone aggreate lead up to 55 km 1000mtr HL |
| 30 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed brick lead up to 80km 1000mtr HL Please Enable Macros to View BoQ information |