| 1 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 2 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 5 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | 5.9.21 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 10 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | 5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 12 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 15 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 17 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 18 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.2 Kiln seasoned and chemically treated hollock wood9.5.2.2 30 mm thick shutters |
| 19 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant(Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 20 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 21 | 13.8 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :13.8.2 1:4 (1 cement: 4 fine sand) |
| 22 | 13.80 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 23 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 24 | 12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 25 | 12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :12.51.1 Ridges plain (500 - 600mm) |
| 26 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.3 Electric resistance or induction butt welded tubes |
| 27 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 28 | 12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runnerwith suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats ofsize 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of allT-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.52.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 29 | 11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 30 | Internal Electrical Works1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 31 | 1.10.2 Group B |
| 32 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 33 | 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 34 | 1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 35 | 1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 36 | 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.1.21.1 20 mm |
| 37 | 1.21.2 25 mm |
| 38 | 1.21.3 32 mm |
| 39 | 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 A switch |
| 40 | 1.24.3 15/16 A switch |
| 41 | 1.24.4 3 pin 5/6 A socket outlet |
| 42 | 1.24.5 6 pin 15/16 A socket outlet |
| 43 | 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.3 4 Module (125mmX75mm) |
| 44 | 1.27.4 6 Module (200mmX75mm) |
| 45 | 1.31 Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 46 | 1.32 Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 47 | 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. |
| 48 | 1.50 Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required.1.50.1 Upto 450 mm sweep |
| 49 | 1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 50 | 2.1 Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRCfuses including drilling holes in cubicle panel, makingconnections, etc. as required.2.1.2 63 A TP&N |
| 51 | 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.3.1 6 way , Double door |
| 52 | 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door |
| 53 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.2.10.1 Single pole |
| 54 | 2.10.3 Double pole |
| 55 | 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.14.2 40 A |
| 56 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 57 | 5.5 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 58 | 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 59 | 5.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 60 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.1 Upto 35 sq. mm |
| 61 | 19.1 Supply installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Curront (BLDC) Motor, class of insulation B, 3 nos. Blades, 30 cm long down rod, 2 nos/ canopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9 Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min, 350 RPM (Tolereance as per IS: 374-2019), THD less than 10 % remote or electronic regulator unit speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (Max.) insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC. Supply, earthing etc. Complete as required. |
| 62 | MR- 1: Supplying with including fitting fixing of Asethetically designed recessed mounted panel in a light weight plastic body available in LED 20 W etc. as required and directed by the deptt. |
| 63 | MR- 2: Supplying with including fitting fixing of ADORE LED PLUS 9 W/ 10W. Etc. as directed by the deptt. |
| 64 | MR- 3: Supplying with including fitting fixing of Metal Exhaust Fan (230 mm) Aeroclean LD GBD etc. as required and directed by the deptt. |
| 65 | MR- 4: Supplying with including fitting fixing of 2 H.P. Motor Pump set as required and directed by the deptt. (Crompton/ Kirlosjar/ Usha or equivalent make). |
| 66 | MR- 5: Supplying with including fitting fixing of 3- Phase 4W ICS DLMS compliant LT Trivector energy meter (Category-A), 3 X 240 V phase to neutral- 5 A Class 0.5s DTR metering. (As per APDCL Rate for SOR- 2020-21). |
| 67 | MR- 6: Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqm, balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq. mm, balance Aluminium strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm and balanced all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part- I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by the deptt.) 10.00 sq. mm 2 core U.G. Cable. |
| 68 | MR- 7: Payment to be made to the APDCL authority for load security. |
| 69 | Land Development2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 70 | ICBP Approach2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 71 | 16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 72 | 16.3 Supplying and stacking at site.16.3.3 53 mm to 22.4 mm size stone aggregate |
| 73 | 13.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 74 | 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 75 | 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 76 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for:4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 77 | 2.3 Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :2.3.1 All kinds of soil Please Enable Macros to View BoQ information |