| 1 | Providing Pump Set - |
| 2 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point |
| 3 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 4 | OD141593/2025-2026:Supply and fixing angle / straight brass lined skirt type, backelite batten holder with 7/9W LEDand plasticshade and giving connection etc as required |
| 5 | 90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm |
| 6 | OD141628/2025-2026: Supply, conveyance, errection, testing and commissioning of DECAN EKKI MAKE 10HP 16 Stage ,240 meter head SUBMERSABLE Borewell Motor Pump set working on 3 phase 415 V, suitably mounted on proposed 50 mm GI pipe etc as required or equallant make. |
| 7 | OD141572/2025-2026: Supply and provide L&T SUBMERSABLE STARTER 13- 21 A WITH PREVENTER with protection against overload, single phasing, phase reversal & severely unbalanced voltages conditions, in accordance with latest IS/IEC suitable for 10 HP Submersibles motor pump set complete duly internally connected |
| 8 | OD141574/2025-2026:Supplying, laying and jointing of the 50 mm sizes of pipes made out of HDPE 6 kg , P 63 conforming to IS 14930 Part II for water pipe etc as required |
| 9 | 90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors. |
| 10 | OD141592/2025-2026:Supply and providing Cable Joint Tape etc. as required. |
| 11 | OD141583/2025-2026:Supply and Providing 50 mm or nearest size UPVC Adaptor Set DC CI with accessories etc |
| 12 | OD141591/2025-2026:Supply and fixing 50mmx 12" GI Barrel nipple |
| 13 | OD141590/2025-2026:Supply and fitting 50 mm or nearest size GI Bend on pumping main with flanges welded and nut bolt etc on pumping main. |
| 14 | OD141597/2025-2026:Supply and fitting 50 mm or nearest size Sluice valve on existing GI pipe with flanges etc |
| 15 | OD141587/2025-2026:Supply and fitting 50 mm or nearest size Non Return valve using required bolt and nut and flange etc |
| 16 | OD141576/2025-2026:Supply and providing clamp set CI 50mm Heavy |
| 17 | OD141595/2025-2026:Supply and fixing 25mm Ball Valve with 15mm nipple and 15mm socket duly welded as required |
| 18 | OD141589/2025-2026:S&I of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipe line as required |
| 19 | OD141581/2025-2026:Supply and fitting 50 mm GI socket etc. as required. |
| 20 | OD141586/2025-2026:Supply and Providing 50 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc |
| 21 | OD141596/2025-2026:Supply and provide NYLON ROPE MAXIMA LG 12MM or nearest size for hanging submersible pump set |
| 22 | OD141578/2025-2026:Supply and providing Cotton waste etc. as required. |
| 23 | OD141573/2025-2026:Supply and providing Shellac 50 ml etc. as required. |
| 24 | OD141580/2025-2026:Supply and fixing 20mm corrugated flexible pvc conduit |
| 25 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 26 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 27 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 28 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 29 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 30 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 31 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 32 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 33 | OD141579/2025-2026:Earthing with pipe earth using 40 mm GI pipe and required accessories including labor charges etc. as required. |
| 34 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 35 | OD141575/2025-2026:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connection etc. |
| 36 | OD141577/2025-2026:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board andgiving connections etc |
| 37 | OD141584/2025-2026:Supply and Installation of dust and vermin proof , wall mounting , Sintex 3 Phasemeter box of size 650x350x250 mm suitable for fixing KSEB meter ,fuse units etc,hinged door connection for the front side with compartments if necessary , providingvision panel for the meter component , knock out for cable entry and exit.( GSMB6535 ) |
| 38 | OD141582/2025-2026:Supply and providing iron hook for binding service wire Please Enable Macros to View BoQ information |