| 1 | Supplying and fixing 160 A,415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [ Make - L& T /Havells/HPL]. [D-2, 3a] |
| 2 | Supply & delivery of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables (A2XWY) for Working Voltage up to 1100 Volts of following sizes [ Make - KEI/Polycab/Gloster]4 Core 50 Sq. mm |
| 3 | Laying only Cable upto 70 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [ F-1,3a] |
| 4 | Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting ,[F-1, 2 d ] |
| 5 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Uto 50 Sq.mm [F-3 ,6i ] |
| 6 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 50 Sq. mm [F-4,7b] |
| 7 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 50 Sq. mm [F-5,8b,xvi] |
| 8 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS. 50 mm dia [F-6,11d) |
| 9 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20 mm [E-16,7a] |
| 10 | 25 mm [ E-16,7b] |
| 11 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-9,1, v ] |
| 12 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9, C1,g1] |
| 13 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes. [F-5,9] 2.5 sq mm [F-5,9,i] |
| 14 | 4 sq mm [F-5,9,ii] |
| 15 | 6 sq mm [F-5,9,iii] |
| 16 | 10 sq mm [F-5,9,iv] |
| 17 | 16 Sq.mm [F-5,9,v] |
| 18 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS175 x 100 x 65 [E-4 ,11,c] |
| 19 | 200 x 150 x 65 [E-4 ,11,d] |
| 20 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board withtop cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17,5.a] |
| 21 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17,5.b] |
| 22 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC. 4 Way ( Up to 160 A ) Make - Legrand, Enclosure (607913) [D-11 , 15] |
| 23 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts boltsetc incl. provision for earthing attachment For 4 Way VTPN ,VERTICAL [D-12,16 ] |
| 24 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [ Make - Legrand / Schneider/L&T) as per direction of EIC.]. 125 A [D-8, 10] |
| 25 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good thedamages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.4 way - Legrand Enclosure (Enclosure 607715)/SIEMENS- Enclosure (8GB32202RC04)) [D-10,14] |
| 26 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]63 A FP [D-5,6] |
| 27 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ] 6-32 SP [ D- 6, 7 ] |
| 28 | 63 A TP [D-6, 7 ] |
| 29 | S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with IP43 protection comprises with 1 nos 25A DPMCB(C-curve 10kA) and 1 no 24 hr digital time switch(L&T,GIC) and 1 no 22A(L&T MNX 22-2P, cat no. - CS90238) power contactor, Starter(North West 11A to 18A ) complete with internal wiring (1.5 sq.mm - control wiring.4.0 sq.mm - power wiring , make - RR KABEL/KEI/POLYCAB/GLOSTER) with suitable size of copper wire including 1 no toggle switch(For Auto/Manual/Off), with Door locking arrangement by common panel keys as used in panel and 2 nos LED( RED color AC ON , GREEN color - AC OFF , must be written in engraving/steel/plastic plate by black color) indicator and earthing attachment as per direction of EIC (Make:- L&T/SIEMENS/ABB/Legrand or equivalent make as approved by E.I.C) . [Note : Timer Connection Scheme : auto/ manual/OFF , Contactor ON - after AC starter ON in auto/Manual Mode , Total Current will be passed through AC starter - AC Load current & Contactor Coil drawing Current] . |
| 30 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1]. |
| 31 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36cmx86.36cmx46cm deep (below Ground level)complete with cemented brick work(1:6) of 25cm width duly plastered with cement morter (inside) CI hinged inspection cover of size36.56 cmx 35.56 cm with locking arrangement,GI reducer including drilling of 46nos. 12 mm dia holes on the GI pipe[3(a)/G-2] |
| 32 | S&F earth busbar of galvanized( hot dip) MS flat 25mm.x6mm. on wall having clearance of 6mm or as per EIC . From wall including provding drilled holes on the busbar complete with GI bolts,nuts,washers etc. as required.[G-2,4.a] |
| 33 | Connecting the equipments body to earth busbar including supply & fixing 25mm x 6mm galvanised (Hot Dip) MS flat on wall / floor with GI saddles as required and connection to equipments including drilling holes with bolts,nuts,washers etc.[G-3,5.d] |
| 34 | SITC of 2.0 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with tropical Rotary compressors cooling capacity-24000 btu/hr, air flow-800 cfm suitable for Refrigerant-R410A/R32 of rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make-O-General/Mitsubishi electric or equivalent make as approved by EIC). incl. Supply & fixing required Angle Iron Structure on wall for installation & fixing of ODU as per direction of E.I.C. |
| 35 | Supply & Laying Extra Add-on items- 5/8\\" (for suction) & 1/4\\"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable(RR kabel/KEI/FINOLEX) incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 2 TR A.C. Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC \\"T\\", elbow, bend etc as per direction of E.I.C |
| 36 | Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (50mm x50mmx 6mm ms angle) of 1.4 m length for making Base frame for installation of AC ODU incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. as per direction of E.I.C incl. Platform. (If required according to the site condition instead of metal arm bracket as per direction of EIC) |
| 37 | S&F of 25mm Dia uPVC pipe for AC drain pipe on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 38 | 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SUPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM.2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL.3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. Please Enable Macros to View BoQ information |