| 1 | Civil Work |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 6 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 7 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 9 | OD343986/2025-2026Fabrication , supply, conveyance & installation of granite name board indicating the cost involved , the commencement, completion and inauguration date. Size 1200mm x 600mm |
| 10 | ELECTRICAL |
| 11 | OD290535/2025-2026Supply, installing, testing and commissioning of 3meter street light pole with 22w LED light, made of galvanized iron pole having 60mm top diameter, 115mm bottom diameter and thickness 3mm, base plate dimension 200x200x10mm,concealed junction box, bakelite sheet fixing provision , outdoor powder coated finish withcoating thickness 28-35 microns , including 4nos. M16X450mm GI foundation bolts with nuts and washers. Light fitting shall be 22 watt LED, die-cast aluminium body,frosted PVC diffuser, 6500K CCT,B22 holder, input voltage AC 110-240V,freequency 50-60 Hz IP44/IP55 protection, complete including, erection, electricalconnections, testing and commissioning, all labour and materials complete. |
| 12 | OD291337/2025-2026Supply of Box for panel Board made out of sheet moulding compound(560x280x150mm size) Surface mounted or recess-in wall (Indoor/Outdoor use) onepiece moulded SMC door with internal hinges. Knockout for wire. |
| 13 | OD328825/2025-2026Supply and fixing HRC fuse base of 20/32A 2- way neutral links mounted on DMC/SMC base and 2.5sq mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 14 | OD343155/2025-2026Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35x75cm,refilling the trench etc.as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm |
| 15 | OD395114/2025-2026Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 17 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 18 | 90.6.5.4Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm |
| 19 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 20 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 21 | OD395323/2025-2026Supply and fixing of 25A 2 Pole AC 1 rated power contractor, 25A Connector,&It;br>Digital timer (2 Nos),suitable copper socket |
| 22 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size Please Enable Macros to View BoQ information |