| 1 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil |
| 2 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 4 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 5 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Sand or other approved stone 50mm thick |
| 6 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. South Zed Black Above 3601 Cm2 Slabs |
| 7 | Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4), Size 600mm x 600mm |
| 8 | P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in allcolour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete, size 600 mm X 1200mm |
| 9 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Full Edge moulding |
| 10 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 11 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' 35 mm thick Decorative teak veneer both side |
| 12 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 13 | Extra for providing other type of fittings as mention in annexure A ( as approved by EI) : Brass fittings |
| 14 | Providing and fixing Nigeria / Ghana /Ivory Coast Teak wood grade-I mouldings and beadings in doors and windows size :- |
| 15 | 25x20 mm |
| 16 | Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 17 | Providing & Fixing decorative veneer of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge, 6.0mm thick veneer |
| 18 | Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification. |
| 19 | Providing and fixing 15 mm thick densified tegular edged ecofriendly light weight calcium silicate false ceiling tiles ofapproved texture as per direction of Engineer-in-charge ofsize 595 X 595 mm in true horizontal level suspended oninter locking metal grid of hot dipped galvanized steelsections (galvanizing @120 grams per sqm) consisting ofmain „T‟ runner suitably spaced at joints to get requiredlength and size of 24X38mm made from 0.33 mm thick(minimum) sheet, 1200mm centre to centre, and cross „T‟ ofsize 24X32mm made out of 0.33mm (Minimum) sheet,1200mm long spaced between main „T‟ at 600mm centre tocentre to form a grid of 1200X600mm and secondary cross‟T‟ of length 600mm and size 24X32mm made out of 0.33mm thick (Minimum) sheet to be interlocked at middle of the1200X600mm panel to form grid of size 600X600mmresting on periphery walls/partitions on a perimeter wall angle precoatedsteel of size (24X24X3000mm made of 0.40mm thick(minimum) sheet with the help of rawl plugs at 450mm centreto centre with 25mm long dry wall screws @ 230mm intervaland laying 15mm thick densified edged calcium silicateceiling tiles of approved texture in the grid including cutting/making opening for services like diffusers, grills, lightfitting, fixtures, smoke detectors etc., wherever required,Main „T‟ runners to be suspended from ceiling using 50 mmlong M 6 dash fasteners, 6mm G.I. fully threaded rods withgalvnised steel L cleat level adjusters of size 80x25x2mm,spaced at 1200mm centre to centre long main „T‟ bottomexposed with 24mm of all T-sections shall be pre-paintedwith polyster baked paint, for all heights, as perspecifications, drawing and as directed by engineer-in-charge.Note :- Only calcium silicate false ceiling area will bemeasured from wall to wall. No deduction shall be made forexposed frames/opening (cut outs)having area less than 0.30Sqm. The calcium silicate ceiling tiles shall have NRC. |
| 20 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :25 mm thick. |
| 21 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 23 | Providing and applying superior quality emulsion for wall painting with Velvet touch/Royal paint etc of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of Engineer-in-charge. |
| 24 | New Work Three or More coat |
| 25 | Old Work Analysis |
| 26 | Dismantling thatch roofing including mats bamboos, jafries etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 meter lead |
| 27 | Repair to damaged plaster with high performance curing free, quick setting cement mortar & confirming to ASTM C 1600 in ratio of 1:4 with following properties of cement : Compressive strength of 20 MPa within 4 Hours, Curing free, bond strength of 4 MPa within 24 Hours, Non shrink & Non toxic in following steps-(i) Chopping loose and cracked plaster to required depth, cleaningthe exposed surface with wire brush, cleaning of plastersurface with water as necessary and getting dried.(ii) Plastering the surface with above mentioned high performancecement sand mortar 1:4 upto depth of 25 mm complete with allscaffolding.(iii) No curing has to be done as the high performance cement usedshould be curing free.(This item is to be used in only emergency situation afterdecided by Engineer in charge ) |
| 28 | Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding. Note : This item to be used for maintence work judicially |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 30 | 20 mm nominal outer dia pipes |
| 31 | 25 mm nominal outer dia pipes |
| 32 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 33 | 75 mm dia |
| 34 | 110 mm dia |
| 35 | 160mm dia |
| 36 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 37 | socket |
| 38 | (i) 75mm dia |
| 39 | (ii) 110mm dia |
| 40 | Reducer 110 X 75 mm |
| 41 | (i) 110 mm dia |
| 42 | Plain Tee |
| 43 | (i) 75mm dia |
| 44 | (ii) 110mm dia |
| 45 | Bend 45 |
| 46 | (i) 75mm dia |
| 47 | (ii) 110mm dia |
| 48 | Plain floor trap |
| 49 | 110mm dia |
| 50 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making hannels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M |
| 51 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floatingneat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr, Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame |
| 52 | P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: |
| 53 | 25mm nominal bore Vertical |
| 54 | Construction of Cement Concrete Chamber 125mm dia. C.P. Brass doom grating |
| 55 | C.I. Grating |
| 56 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 57 | Short point (up to 3 mtr.) |
| 58 | Medium point (up to 6 mtr.) |
| 59 | Long point (up to 10 mtr.) |
| 60 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 61 | On board |
| 62 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, ound / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated river, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum ower consumption should not more than the specified rating nd Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name ngraved/ Embossing/ Screen printing on housing. OEM must ave its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer nnexure \\"A\\" attached with this BSR , Minimum lumen output 1950 lm |
| 63 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 64 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 65 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 66 | Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 250 mm sweep |
| 67 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action djustable thermostat , Dual indicating lamps Injected PUF insulation, ulti Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloy connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 15 Ltr |
| 68 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R- 410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1.5 TR ISEER not less then 3.8 |
| 69 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 70 | Armoured 2 core x 2.5 Sq.mm |
| 71 | Armoured 2 core x 1.5 Sq.mm |
| 72 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 100 mm dia per running inch length |
| 73 | Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 74 | Dismantling of existing toilets i/c dismantling of wall and floor titles with plaster, GI pipes, CI pipes with fittings, sanitary wares complete with care & as per direction of E.I. |
| 75 | Carriage of Building Rubbish Stone metal (All dismantled material) as per direction of E.I. |
| 76 | Recovery of the dismantled material (old pipes, sanitary ware, CP fitting, electric fixture etc) of toilets |
| 77 | P/F looking mirror 6 mm thick on walls (Atul/eqnivalun t) with back of 6mm thick water proof ply, with eaching work on glass and fixed with 4 nos SS bolt with cap. With Edge Moulding As per consultant. Complete as per direction of E.I. |
| 78 | Recovery of the damaged windows, wooden doors, frames taken out from rooms & toilets |
| 79 | Door shutter room and toilets |
| 80 | ventilators toilets |
| 81 | Providing & Fixing Premium Quality (Hindware/ Cera make) white glazed WC vitreous china Sanitary Wares as per direction of Engineer-in-charge including cutting and making good the wall and floor, Wall Mounting European type W.C with seat cover and Concealed cistern with plate |
| 82 | Providing & Fixing premium quality (Hindware/ Cera make) WVC Wash basin counter top of Size 500 mm x 400 mm dia |
| 83 | Providing & Fixing Jaguar Continental prime series or equivalent make as approved 1. Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange with waste coupling as per approved by Engineer in Charge. |
| 84 | Angular stop cock with inlet connection, long thread 15 mm nominal size |
| 85 | washbasin concealed body single lever divertor with spout i.c CP plate |
| 86 | Wall mixer concealed single lever divertors of superior quality and approved make: C.P. brass Tip-tone divertor bath spout with mixing valve. |
| 87 | 600 mm long towel rail |
| 88 | Revolving type towel ring |
| 89 | Soap dish |
| 90 | Double coat hook |
| 91 | 190 mm rain shower |
| 92 | Shower arm length 450mm |
| 93 | Paper holder |
| 94 | Health focet (Premium heavy Quality) as approved byEngineer-in-Charge |
| 95 | Providing and fixing Jaguar Continental prime series or equivalent make as approved by E.I. Towel rack 600mm long 260mm wide with lower hangers CP Brass fittings of approved make as per direction of Engineer-in-charge |
| 96 | Add extra for using premium quality tiles like Kajaria/ Somany or equivalent of following size |
| 97 | MAT & GLOSSY finished ceramic tile Size 600mm x 600mm and Heavy Duty Vitrified Double Charged tiles size 600 mm X 1200mm |
| 98 | Labour charges for dismantling of existing old unserviceable electrical wiring with conduit, switch board, switches and sockets etc |
| 99 | Recovery of old dismantled/ unserviceable electric wiring with conduit, switch board, switches and sockets etc |
| 100 | S&F heritage type brass mirror light fixture with cut and round glass including 2 x 15 W LED lamp, all as per approved sample by consultant /E.I. |
| 101 | Cleaning of shaft, main hole and neccassary reparing by cement plaster wall and chamber and painted black paint on CI pipe (i/c stop the any seepage and leakage from CI and GI pipe |
| 102 | Add extra for using superior quality make carbitte, switch, sockets, plate, box etc. In place item no. 1 or 2 part C Electric (Total amount 78951.00 @ 20% |
| 103 | Dismantling of existing of Room gallary Wooden false Ceiling as per direction of E.I. |
| 104 | Jhiri cutting for electrical wiring, box fixing etc complete with cement mortar repair as required and as per direction of E.I. Please Enable Macros to View BoQ information |