| 1 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window as per DSR-14.4.1 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. as per DSR-15.7.4 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. as per DSR-15.56 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 4 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. as per DSR.-15.27 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 5 | Dismantling stone slab flooring laid in cement mortar including stackingof serviceable material and disposal of unserviceable material within 50metres lead. as per DSR-15.25 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. as per DSR-15.60 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration as per DSR.-2.35.3 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 8 | Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) as per (DSR-6.4.2+6.5) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 9 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood (35 mm thick shutters) (a) Single leaf as per DSR-(9.5.1.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 10 | 15 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) as per DSR.-13.2.2 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 11 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (2.25FM) as per DSR.-13.4.2 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 12 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete. 11.46.2 Size of Tile 600x600 mm as per DSR.-11.46.2 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 13 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. as per DSR-11.40 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 14 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. as per DSR-8.31 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 15 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm as per DSR-8.2.2.1 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture as per DSR-13.48.3 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 17 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture as per D.S.R-(13.48.2) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per D.S.R-(13.46.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 19 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats as per D.S.R-(13.51.2) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. as per D.S.R-(13.80) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 21 | 9.62 Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378). (a) 300mm x 16mm . as per D.S.R-(9.62.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 22 | 9.63 Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (a) 250 mm x 10mm as per D.S.R-(9.63.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 23 | 9.66 Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (a) 125 mm as per D.S.R-(9.66.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 24 | Providing and laying integral cement based water proofing treatment (brick coba )including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. as per DSR-22.7.1 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 25 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). as per DSR-10.28 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 26 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptableVentilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. 9.147.D1.1 Using R1 series with frame (33 mm & above ) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre). as per D.S.R-(9.147.d1.1) Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 27 | Providing and fixing of alluminium door with complete acessories. as per Analysis Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) |
| 28 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick as per DSR-26.87 Complete in all respect as per Direction of Engineer in Charge. (Including labourcess but excluding GST) Please Enable Macros to View BoQ information |