| 1 | Istallation testing and Commissioning of Air Conditioner |
| 2 | OD368593/2025-2026:Supply, installation testing and commissioning of 2 TR 3 star rated split Inverter typeairconditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50Hz single phase AC supply fitted with hermetically sealed compressor operating on R22/ono CFC refringent with condensing and evaporating unit capable for cooling air circulation and filteringetc. Including refringent copper piping with insulation up to 5 Meter or required lengthmicroprocessor control with cordless remote control and providing wall mounting stand for theoutdoor unit etc-Inverter AC (With extended two year warranty period). Blue star /LG/ equivalent. Alongwith Supply and Fixing of 5 KVA Voltage stabilizer V Guard with input voltage of 170 -270Vand Output Voltage range of 210 to 240V with Overload Protection time relay, Indicators andChord Wire etc as required |
| 3 | OD369870/2025-2026:Supply, installation testing and commissioning of 1.5TR 3 star rated split Inverter typeairconditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50Hzsingle phase AC supply fitted with hermetically sealed compressor operating on R22/ono CFCrefringent with condensing and evaporating unit capable for cooling air circulation and filteringetc. Including refringent copper piping with insulation up to 5 Meter or required lengthmicroprocessor control with cordless remote control and providing wall mounting stand for theoutdoor unit etc-Inverter AC (With extended two year warranty period). Blue star /LG/ equivalent. Alongwith Supply and Fixing of 4KVA Voltage stabilizer V Guard with input voltage of 170 -270Vand Output Voltage range of 210 to 240V with Overload Protection time relay, Indicators andChord Wire etc as required |
| 4 | OD368595/2025-2026:Drain pipe for condensate drain to the nearest drain point with 32mm U PVC pipe insulatedusing 9mm thick Nitrile Rubber tubing as per Client/Engineers instruction. |
| 5 | OD368594/2025-2026:Supply and providing following size soft drawn Copper pipe for extending pipe between outdoor and indoor units including insulating pipe using rubberized foam sleeve 10mm thick,brazing, leak testing etc. 3/8"(9.52mm) and 5/8"(15.8mm) 22 gauge |
| 6 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 8 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 9 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 10 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 11 | 90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 12 | 90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 13 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 14 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 15 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 16 | OD370162/2025-2026:Supply and installation of 3P 63A, MCB in exsting panel |
| 17 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 18 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 19 | OD370164/2025-2026:Charges for preperation of KSEB test Report for submitting to the concerned KSEB sectionoffice Please Enable Macros to View BoQ information |