| 1 | CIVIL WORKS |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 6 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 8 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 9 | OD296028/2025-2026Fabrication, supply, conveyance and installation of ACP sheet name board indicating the cost involved, the commencement, completion and inauguration date etc. |
| 10 | OD296029/2025-2026Fabrication, supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc |
| 11 | Electrical Works |
| 12 | 90.15.1.2Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nosfixed in existing RCC foundation adn junction box etc, complet 9 Meters |
| 13 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 14 | OD296025/2025-2026Supply of Box for Panel Board made out of Sheet Moulding Compound (560 x280x 150 mm size) Surface mounted or recess-in wall (Indoor/Outdoor Use)Onepiece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt. |
| 15 | OD296022/2025-2026Fabrication and fixing of the Panel Board Stand with 2 legs made up of B classGI pipe 32mm dia 1.8mtr. length. 32 mm dia G.I pipe ( medium class) |
| 16 | OD296024/2025-2026Supply of Meter Box made out of Sheet Moulding Compound (430 x 265 x 170 mm size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One piece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt and earthing of the meter box. |
| 17 | OD296020/2025-2026Fabrication and fixing of the Meter Box. Stand with 1 leg made up of GIpipe<br>40mm dia 2.5mtr. length.<br><br> |
| 18 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 19 | OD296021/2025-2026Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25AConnector,<br>Digital timer Suitable Copper socket, |
| 20 | OD296019/2025-2026Supply Conveyance and Installation of Surge protector device of IP 20,Mountingtype: Screw,Voltage protection level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,N-PE:7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60 KA, Response time :<35 ns, Ta: -10-55. |
| 21 | OD296023/2025-2026Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- wayneutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable. |
| 22 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 23 | 2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 24 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 25 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 26 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 27 | 90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 28 | OD296026/2025-2026Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 29 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 30 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 31 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 32 | 90.12.1.13Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm |
| 33 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 34 | OD296027/2025-2026Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 6 sq. mm(19mm) |
| 35 | Connection charges - KSEB (Actual amount production on Receipt) Please Enable Macros to View BoQ information |