| 1 | Swaged steel tubular pole ( 410SP-2) of height 7 Mtr. onfirming to IS:2713 (Part II ) in three section with steel base size, bottom of the pole made of 50 mm dia MSB Clamp pipe welded to 300 mm long MS canopy of suitable dia at an angle of 102.5 suitable size of nuts and bolts including rating of one cost steel primer and two coat of read - oxide all complete as required. (Without Arm) |
| 2 | Single Arm 1 Mtr long |
| 3 | Double Arm (1x2) Mtr Long |
| 4 | Eraction of metallic street lgiht standard pole of length exceeding 6.5 mtr but not exceeding 8.5 mtr in cement concrete 1:3:6 (1 Cement :3 coarse sand : 6 graded stong aggrate 40 mm nominial size) foundtion with cemetn cocrete collar of size 0.5 m dia x 0.5m height to accommadate the looping type cable end box includgin excavation and refilling etc as reqd. |
| 5 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 6 | a) 90/100W LED Street light |
| 7 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
| 8 | a) 200W LED Flood light |
| 9 | Supply of 16mtr. High mast in two section Construction S355 grade as per BS-EN 10 025 Top Dia 150mm, bottom dia 360mm, plate thickness 3mm, 20side polygon, galvanisation as per BS EN ISO 1461, base plate dia 520mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/s with 6 nos foundation bolts of PCD 445mm TS 600/ 24mm dia/850 mm long. Luminaries carriage : Material for 40 NB ERW Class B – M.S. Pipe, dia of carriage ring 450mm (ID) with 8/12 arm, welded, 2 sections having carrying capacity upto 8/12 luminaries. Trailing Cable : 5 core 2.5sq.mm. PVC flexible copper conductor Winch/Power Tool : Double drum, SWL 350 kg with 1HP 6 pole single speed integral motor Rope : Grade AISI 304, 7/19 construction, dia 5mm, BLC 1450 x 2 having 2 nos of continues rope. Aviation obstruction light : twin dome aviation obstruction lights LED type as required. Feeder Pillar : control panel housing 63A TPN MCB incomer, single dial timer, 45A contactor circuit for the automatic control of luminaries power tool control with 2 no 9A contactors and raise lower push button, incoming 35sq.mm. and outgoing 16 & 2.5 sq.mm. terminals. |
| 10 | For 16 mtr. High mast : ITC of the high mast and light fixture with the help of suitable tools and plants, wiring of luminaries with all wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T/ mtrs sq. for 16 M High mast. |
| 11 | Outdoor stand mounted Feeder Panel with 63amp TP&N, MCB incomer, 65amp TP contactor automatic switching of luminaries, power tool control incommer outgoing terminal etc as reqd. (for high mast) |
| 12 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
| 13 | 240W LED flood light |
| 14 | Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required |
| 15 | a) 3x1.5 sq mmm |
| 16 | S/F suitable sizes PVC sinatex box with MCB, cable connector including locking arrangemetn connection etc as reqd. |
| 17 | S/L L.T Power XLPE PVC sheathed (Heavy duty) Al conducotr armorued cable for working voltage 1100v IS:1554 (part I) 1989 Make- Havells/ Polycab/ Finolex/ or equi) |
| 18 | a) 2x10 sq mm (for Security lgiht) |
| 19 | b) 2x6 sq mm (for Flood light) |
| 20 | c) 4x16 sq mm (for High mast light) |
| 21 | d) 3.5x35 sq mm (for electrical room to panel) |
| 22 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
| 23 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 24 | 16 sq mm aluminium lugs |
| 25 | 10 sq mm alluminium lugs |
| 26 | 35 sq mm aluminium lugs |
| 27 | Fabrication installation with 16 SWG MS sheet with one coat steel primer and two coast spray painting with approved agade making PCC plinth and foundation including fitting fixturing connection transportation upto work site labour charge etc all complete as reqd. |
| 28 | 25-100Aamp MCCB 10KA fixed thermal seeting- 1 Nos |
| 29 | 40 amp DPMCCB 4 Nos |
| 30 | 63 Amp TPN MCB- 4 Nos |
| 31 | Digital Vot mtr (0-500 volt) 3 Phase class 0.5- 1 Nos |
| 32 | Ditital Amp Mtr (0-500 Amp)-3 Phase class 0.5- 1 Nos |
| 33 | C.T coil of C.T Ratio 300/5-1 Nos |
| 34 | LED Indicator lamp R/Y/B/G- 1Nos |
| 35 | 25 mm x 5 mm copper strip (1.15 kg/ mtr)-8 Kg |
| 36 | Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required. |
| 37 | a) 100 Amp TP&N |
| 38 | Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required. |
| 39 | a) 200 Amp |
| 40 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 41 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 42 | CGST @ 9% |
| 43 | SGST @ 9% |
| 44 | Labour Cess @ 1% Please Enable Macros to View BoQ information |