|
| 1 | Footpath Lighting |
| 2 | OD262591/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter heightabove theground level made out of GI, tubular pole having two section section, bottom sectionofminimum 900/1000mm with base dia of 114mm and upper section of minimum2300/2000mmwith minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shallhave base plate ofdimension 200x200x12mm/round minimum 200mm including minimum16mmdiameter 4 numbers foundation bolts of450mm bolt length, 200mm pitch circle diameter manufactured from special steelalong withnuts, washers, The pole shall be with inbuilt control gear tray at bottom section. Thecontrolgear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 wayterminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector andprovisionfor earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987.Designcomply EN40 standard and basic wind speed 169kmph. Pole should hot dipgalvanized to 65microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given withtwo coatsof epoxy primer and above that it should be given marine coating. The completesystem shouldbe hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO). |
| 3 | OD262586/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimumdimension315mm width and 545mm height, BIS certified with a bodyand frame of high pressure die cast aluminium, a frosted PMMA protector (IK06)fixed on tothe optical unit, separate optical and control gear compartment accessed by opening fourscrews at the top of the luminaire, a vent pressure equalization unit and pre-cabled asrequired. The luminaire shall have ingress protection of IP66. Highly efficienttemperatureresistant lenses for light distribution with several optical options providing excellentphotometry to optimally cater to different applications. Overall system efficiency of120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index(CRI) >70and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,PowerFactor > 0.95, with BIS certified potted driver having internal surge protection of 4kV andan additional surge protection device (SPD) of 10 kV . ( Klite DYNASTY MIDI 50WWW/KESSLEC RILA 50W WW) |
| 4 | OD326545/2025-2026:Supply ,conveyance ,installation testing and commissioning of 1200 mm 1x20 W LED tube light fitting housing made of extruded thermal polycarbonate with 6500K , color temperature with duly wired up for use on 230V AC . The light fittings shall be fixed directly on wall or ceiling with and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. |
| 5 | OD326557/2025-2026:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 120lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 6 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 7 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 8 | OD262588/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 10 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 11 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 12 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 13 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 14 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 16 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 17 | 90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 18 | OD262581/2025-2026:Hire and Labour charges for Concreate/Tar road cutting as required. |
| 19 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 20 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 21 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 22 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 23 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 24 | OD262585/2025-2026:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L/k) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required |
| 25 | OD262590/2025-2026:Supply and fixing Digital Time switch 240V AC DIN/BASE mounting in the existing enclosure and giving connection as required (LK 110-240 V Digital Time Switch) |
| 26 | OD262587/2025-2026:Supply and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 27 | OD262582/2025-2026:Supply and fixing of Neutral link 32A, 2 way neutral links mounted on DMC/SMC base. |
| 28 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 29 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 30 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 31 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 32 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 33 | OD262589/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip |
| 34 | OD262592/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.25 mm X 3 mm G.I. strip |
| 35 | OD262583/2025-2026:Supply and fixing 32mm dia 6Kgff/cm2 PVC Pipe including fixing the pipe with clamp/clips at 60cm spacing. etc. as required (for service pipe) |
| 36 | OD282858/2025-2026:Supply and Fixing Syntex junction box GSJB 2520 With Provision for fixing 2pole isolator/DP MCB/TP MCB Please Enable Macros to View BoQ information |