| 1 | SITC of Highmast Light |
| 2 | 90.15.1.2:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos fixed in existing RCC foundation adn junction box etc, complet 9 Meters |
| 3 | OD349822/2025-2026:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system trailing cable, connector, integral power tool motor, manual handle, junction box, and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connectors 24mm diameter foundation bolts of 750mm bolt length, 385mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate foundation bolt minimum 6 nos fixed in existing RCC foundation and junction box and supply and fixing control panel made of 2 mm CRCA sheet as per approved design and requirement, with front access facility, hinged doors, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, interconnection etc, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication for fixing Energy meters and all accessories ,heavy duty 'A' section neoprene gasket in the panel board A'section neoprene beeding suitable for 1.60/ 2.00 mm sheet and necessary 24 Hours Analog Timer for operating automatic ON-OFF function ,10/16A, 2Pole, AC 3 rated power contactors with 1NO+1NC auxiliary contacts & with AC coil for switchin lights, motor forward and reverse operations ,16/25A DP MCB ,25 A, 2 pole, 100 mA RCCB, Auto /Mannual switch, Push buttons, Indicators, DIn rails for mounting MCBs RCCB, 32A Bakelite HRC fuse, Nutral link,, MCBs all control wiring including necessary angle iron frame work for fixing the control pannel etc, complete 12 Meters |
| 4 | OD249245/2025-2026:Supply Conveyance, installation, testing and commissioning of 24000 lumen LED, efficacy>=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonatecover complete with THD 0.95, RoHS compliant, duly wired up foruse on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip makeCree/Osram/lumilled/Nichea/Bridgelux duly wired up for use on 230V AC supply.(LM79&80 certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 5 | OD249578/2025-2026:Supply Conveyance, installation, testing and commissioning of 12000 Lumen LED Flood lightoutput greater than 120 lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protectionup to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover completewith THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up foruse on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 6 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 7 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 8 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 9 | OD213411/2025-2026:Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. |
| 10 | OD213413/2025-2026:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required. |
| 11 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 12 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 13 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 14 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 15 | 90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 16 | OD249605/2025-2026:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board and making support to the service pipe. |
| 17 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 18 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 19 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 20 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 21 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 22 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 23 | OD249250/2025-2026:Supply and fixing Time switch 240V AC DIN/BASE mounting(Analog version)in the existing enclosure and giving connection as required |
| 24 | OD213426/2025-2026:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (LnK) conforming to IS/IEC60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required |
| 25 | OD213412/2025-2026:Supply and fixing 32A HRC fuse base with HRC fuse link- |
| 26 | OD213414/2025-2026:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base- |
| 27 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 28 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 29 | 90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 30 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 31 | OD213425/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.25 mm X 3 mm G.I. strip |
| 32 | OD213420/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip |
| 33 | OD349964/2025-2026:Supply and laying 25x6 mm GI strips laid 0.60 m below ground level including excavatingtrench of suitable size and refilling etc. as required |
| 34 | OD213422/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x3 mm brass nut and bolt |
| 35 | OD213418/2025-2026:Supply and fixing 32 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe) |
| 36 | OD213419/2025-2026:Fabrication,supply,conveyance and installation of Granite name board with table rubbed, edges rounded and polished, of size 75x50 cm deep and 18mm thick, indicating the cost involved, the dates of commencement, completion, inauguration etc on stone slab Please Enable Macros to View BoQ information |