| 1 | SUB HEAD 1 ---Compound Illumination |
| 2 | Supply & Delivery of Flood light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 45o C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66, IK - as specified below, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, |
| 3 | lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), |
| 4 | SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 degree C). System lumen efficacy ≥110 <135 lm/Watt (IK-8) |
| 5 | 60 W (For Badminton Court..) |
| 6 | 100 W (For Pole Light.) |
| 7 | Supply & Delivery of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 45o C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66, IK - as specified below, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, |
| 8 | lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), |
| 9 | SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90o C). System lumen efficacy ≥110 <135 lm/Watt (IK-8) |
| 10 | Supply & Delivary LED Decorative Post Top light fitting in Pressure die cast Aluminum base with Prismatic polycarbonate diffuser having following wattage, with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 40,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 11 | 40 Watt |
| 12 | Supply & Errection 7 M height dip galvanised octagonal pole made of HT steel of grade S355 of BSEN 10025 with 155 mm bottom A/F & 70 mm top A/F made up of 3mm thick G.I Sheet along with base plate of size 250 x 250 x 16 mm thick with in built terminal box for cable connection as required inclusive of \\"J\\" type Foundation bolt (size- M20 X 600) & 0.5M circular arm bracket (angle should be decided by EIC) also backelite sheet with two 6A. SP MCB and 16 sqmm stud type connector is considered and making necessary connections using 2.5 sqmm PVC insulated single core stranded annealed copper wire as required, including mending of any damages. (MAKE-BAJAJ/CROMPTON/ TRANSRAIL/VELONT/UTKARSH) |
| 13 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting |
| 14 | S&F 18\\" radius (Pipe Required-5ft Long) Circular Shaped structure made by 32 mm dia (ISi-Medium) Gl pipe on pole cap by welding incl. providing Support a four cornerby by 4x 18\\" long 32 mm dia GI pip & inclusive providing Support on pole by 4 x 12 mm dia 18\\" long ms Rod and making Suitable Size Hole on GI pipe foe nut, boll etc incl painting & mcl S&F pole cap of 100 mm dia 300 mm long as per direction of EIC.Fixing on 2 nos 6 Mtr round pole for Badminton Court. |
| 15 | Erection of single steel tubular pole /GI pole of length as given below with/without sole plate & cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block included sole plate /pole with hard jama metal included CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level included 3 mm thick neat cement finish and GI earth bolt after making drilled holes etc on pole & carriage of pole upto 1.6 km from store to work site including filling up the excavated carth pit with shifted soil and ramming properly a) (upto9.0 mtr) size 0.6x0.6x1.70 mts (for Badminton Court). |
| 16 | Supply & Grouting (into a suitable depth) the 1.5 mteter long 40mm GI pipe (ISl-M) in Gate Pillar as per DIR of EiC incl painting with two coats of Aluminium paints over one coat of R.O. primer of approved make after preparing the surface with emery paper as to G.S. |
| 17 | Supplying & Fixing GI/PVC waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 18 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 19 | Sub Head:2 Supply and Laying of Cable |
| 20 | Supply of 1.1 KV grade PVC/AL AR Cable 4 core 6sq.mm. (Havells /Finolex /Polycab /KEI) for Gatelight/Glow Sign. |
| 21 | Laying of cable upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 22 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 23 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below:- |
| 24 | 4 core 6 sqmm |
| 25 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 26 | 4 core 6 sqmm |
| 27 | SUB HEAD 3 ---Glow sign Board |
| 28 | SITC of 3 nos. Glow Sign Board (1 no.6ft x 3 ft x 8 inch depth) made from 40x40x5mm MS angl, 40x5mm MS flat having the provision for opening back side by 25x25x5mm MS angle with required number of hinges duly welded. There will be vertical support in each 4ft length and as per direction of EIC. The entire board should be painted with one coat of synthetic enamel paint over one coat of RO primer. |
| 29 | The front and side facia of the board is to be made with 2mm thik White PVC sheet of export quality having suitable size and to be fixed by required SS screws. The back side of the board should be enclosed by 20 SWG GI SHEET. S & F 25X25X6 mm aluminium angle by SS Screws at peripheri of the board. The matter is to be incripted on a whole best quality venyle sheet as per approved size, colour & matter which will be pasted properly over the PVC sheet. Inscripton of the board will be provided at the time of layout. Demo incription should be approved by EIC before finalization. |
| 30 | Installation the same Glow sign board at suitable place by making suitable sized RCC muffing & neet cement finishing etc.with two nos 32x32x6 mm MS angle iron bracket for support on the back side rigidly grouted or drilling for support on the back side rigidly grouted or drilling hole for protection support on the back side rigidly grouted or drilling hole for protection support by heavy type screw/nuts & cement net finish etc. & painting. |
| 31 | SUB HEAD 4 -----SITC of Lightning Protection System |
| 32 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc only grouted on the parapet etc in CC mortar.(4.2.1) |
| 33 | Cutting cornices/steps etc including cutting recess in buildings etc & supply & fixing 15mm bore (ISI Medium) GI pipe protection as below and mending good damages to the building works. Length uptyo 0.5 Mtr. |
| 34 | Making soldered joints between conductors, conductors and airterminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. |
| 35 | Making soldered joints between conductors and down pipes/other metallic objects for 14 SWG GI (Hot Dip) wire, including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. |
| 36 | Hiring charges for scanfolding arrangement including dismanlingant the end of work and carriage for LC installation, per storey of building for vertical run. |
| 37 | Supply & fixing of GI (Hot Dip) strips 20mm x 3mm thick for horizontal run on the Parapet/Roof/Wall with GI saddles 1100mm apart incl. mending good damaages to building work. |
| 38 | Supply & fixing of GI (Hot Dip) strips 20mm x 3mm thick for vertical run on wall with GI saddles spaced not exceeding 1000mm apart incl. mending good damages to building work. |
| 39 | Making soldered joint between conductor/ down pipes/ other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of bituminous paint. |
| 40 | Supply & Fixing of Testing Joints by 20mm x3mm thick GI (Hot Dip) strip 125 125mm long grouted on wall having clearance of 6mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc as required. |
| 41 | Earthing 50mm dia dia GI pipe 3.64mm thick x 3.04 Mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 Mtrs long), 13mm dia x 80mm long GI bolts, double nuts, double washers incl. S&F 15mm dia GI pipe protection (1 Mtrs long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mtrs below the ground level as below by (ISI- Medium) GI pipe. |
| 42 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) |
| 43 | S&F earth busbar of galvanized (Hot Dip) MS flat 40mm x 6mm on wall having cleavance of 6mm from as per G.S. |
| 44 | SUB HEAD 5--Lift/Pump/Garage/Compound Light Panel/Gate Light/Security Gurad |
| 45 | Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. 160A DIN type HRC fuse as per GS.(Make:Standard/Legrand/Siemens/Havells) |
| 46 | Supplying and fixing 6 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- LEGRAND/ABB/SIEMENS) |
| 47 | Supplying and fixing 415 V 160A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make- LEGRAND/ABB/SIEMENS) |
| 48 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. |
| 49 | TP MCB 63A.(Make- LEGRAND/ABB/SIEMENS) |
| 50 | TP MCB 32A (Make- LEGRAND/ABB/SIEMENS) |
| 51 | SP MCB 6-32A (Make- LEGRAND/ABB/SIEMENS) |
| 52 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (2 Way ) |
| 53 | Spplying and fixing 240/415 V MCB of Breaking capacity 10kA T & C characteristics on din rail of existing DBs and necessary connection. DPMCB (6-32) for compound Light |
| 54 | Supply & fixing of required size of hylam sheet (phenolic laminated) on angle iron frame on wall for installation of service meter incl. S/F of 3 nos 200 A BPC make cut out with base & 1 no. neutral bar as per direction of E.I.C. |
| 55 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information |