| 1 | electrical |
| 2 | OD475012/2025-2026:Supply of 1.5 hp, 1.10 KW, 230V, single phase, 100 mm bore well, premium submersible motor pump set suitable for 32 mm (1.25 inch) delivery pipe, water discharge of 3000 LPH at 30mtr head and a minimum head range of 30 to 176 mtr, (Make: Kirloskar KU4 0321 ,21 stages or its equivalent Deccan/Texmo make. |
| 3 | OD475014/2025-2026:Supply and providing single phase submersible pump controller with ammeter, voltmeter, start/run capacitors, 2P contactor,Guards against dry run, under-voltage, and over-voltage. etc suitable for 1.5 HP submersible pump. ( L&K MR-GiA(0.5 tp 3 HP) or equivalent make) |
| 4 | 90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 5 | OD475020/2025-2026:Supply & fixing the following Power Capacitors in position and giving connection.1 KVAr, 1 phase, 240 V, Metalised Poly Polypropylene Capacitor, Cylindrical Type, suitable for direct connection to motors. |
| 6 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 7 | OD504870/2025-2026:Supply and providing 32 mm (1.25 \\") size, medium duty (Green) column pipe of 3 mtrlength, for bore well submersible pump as required. |
| 8 | OD474982/2025-2026:Supply and providing 32 mm size bottom and top adapter set for column pipe of submersible pump as required. |
| 9 | OD474988/2025-2026:Supply, threading and providing 40 mm dia medium class G.I. pipe in position with accessories like coupling, x-nipple, reducer etc. for extending as required. |
| 10 | OD474993/2025-2026:Supply and providing 40 mm size, heavy duty, flange coupling set with washer and 4 nos SS nut, bolt, plate washer etc suitable for (2") GI pipe jointing as required. |
| 11 | OD474989/2025-2026:Supply and providing 40 mm size medium class G.I. bend in position with accessories as required |
| 12 | OD474983/2025-2026:Supply and providing 40 mm size screwed type Gunmetal horizontal Non-return valve as required. |
| 13 | OD474990/2025-2026:Supply and providing 14 mm size nylon marine rope (white/green) for hanging the pump set in well, tying with an out side object as required. |
| 14 | OD504862/2025-2026:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.40 mm dia 10.Kgf/cm2 |
| 15 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 16 | OD474992/2025-2026:Labour charges for conveyance fixing, lowering and erection of submersible motor pump set in bore well with power cable connections, delivery pipe, nylon rope, trial run etc as required. |
| 17 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 18 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 19 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 20 | 90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run |
| 21 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 22 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 23 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 24 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 25 | OD474986/2025-2026:Supply and providing Test joint for earthing made up of 2 nos, 25x5 mm GI strip, 25 cm long placed on either sides of earth leads and watering pipe, bending, drilling and tightening with 4 sets of brass/SS nut, bolt, washer etc as required. |
| 26 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 27 | OD504872/2025-2026:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 28 | 90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 29 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 30 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 31 | OD474987/2025-2026:Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required. |
| 32 | OD474994/2025-2026:Supply and providing the following size of bolt & nut with washers on the existing MS boxes/ earth bus etc as required including drilling necessary holes as required. 12x3mm brass nut & bolt. |
| 33 | OD475022/2025-2026:Supply and providing end cap and clamp for borewell |
| 34 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 35 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point |
| 36 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 37 | OD503258/2025-2026:Supply and providing Normal size 5/7 W LED lamp in the existing light fittings/holder as required. |
| 38 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 39 | 2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole and netural |
| 40 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 41 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 42 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 43 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 44 | OD474997/2025-2026:Supply and providing M8 eye bolt hook in wall / parapet for binding support for KSEB service main. |
| 45 | OD504864/2025-2026:Supply and providing dust and vermin proof, wall mounting, Hot press moulded SMC Meter Box of following sizes suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit, with 700x480x200 mm or nearest size. (Sintex GS-MB 7450 or equivalent make). |
| 46 | OD504865/2025-2026:Supply and fixing 63A backelite HRC Fuse unit with HRC fuse link in the existing meter board and giving connections as required. |
| 47 | OD504866/2025-2026:Supply and fixing 63A ,415V ,2 way neutral link mounted on DMC/SMC base in the existing meter board and giving connections as required |
| 48 | OD474991/2025-2026:Preparing completion and test certificates for KSEB connection Please Enable Macros to View BoQ information |