| 1 | CIVIL WORK |
| 2 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- (i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (ii) Applying Epoxy primer on the exposed steel bars. (iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush. (iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. (v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. (vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. |
| 3 | Providing and fixing of Un perforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width height of 32mm. The Tile will be manufactured on advanced equipment that includes several leveling stages in the manufacturing process by approved manufacturers. Tile ends will be raised with pips and slops to ensure positive engagement into the spring to enable for de-mounting of individual panels. The Tile sides will be sufficiently high to ensure a minimum deflection across the length of Tile. All Tiles will be bevel edged. The Tile shall be epoxy polyester powder coating with ANTIBAC in white colour which is in compliant to ROHS directive. The Tile shall be cllpped into clip in rail of 0.5mm thick GI. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G .I rod, Hold on Clamp with Clip. POWDER COATING SPECIFICATION: Aluminium PANELS, cleaned through eco friendly cleaning ,process and powder applied through electrostatic charged Automatic Carona technology spray guns and cured in combination of Infrared & hot air oven in a certified plant as Akzo International approved applicator . The powder is conforming with the performance requirements of the AAMA2603.02 & Qualicoat Claa 1 specifications. The coating thickness will be minimum 60 microns with properties of Salt Spray of 1500 hrs in exposure in SST Cabinet with Minimum blister rating 8.(Tensile strength of suspension-344/413 mpa and fastner strength-110kg)All Ceiling Panels shall adhere to GreenPro Certifications. |
| 4 | Supply and Installation of WALL – PREFABRICATED INSULATED PPGL PANEL:Walls: Insulated sandwich panels for wall of total thickness mentioned below. Panel shall have 0.50mm (+/-0.04mm) thick pre coated metal sheet on both sides of rigid PUR insulation. The pre-coated metal sheet shall be PPGL (Pre Painted Galvalume Sheet with AZ coating) sheet having SDP (Super Durable Polyester) colour coat of 18 micron (min). The panels shall be vertically joined together with adjacent panel by tongue and groove joints. For joining, wall panel's metal sheet facings must have lengthwise flange (U shape) of 8mm x 8mm on groove side and 8mmx12mm on tongue side of panel. The pre-coated metal sheet (PPGL) must also be pre-strengthened by full lengthwise stiffening with semi-circular beading of 12mm width & 3 to 4mm depth at 240 (+/-5) mm pitch. Panels may have optional provision for inbuilt electrical conduit running lengthwise atvertical center of specified panels. The insulation core shall be self-extinguishing DIN 4102,Class B3 fire retardant class rigid PUR with thermal conductivity of 0.025 W/mK and with density of 40kg/m3 (+/-2kg) suitable for temperature range of -30 degree C to +80 degree C. The panel must be made using glue-free high pressure pressing self-bonding method. PPGL sheet on both sides of panel shall have a min15 micron protective plastic guard film to avoid scratches during transportation.Thickness 55mm (+/- 2mm) |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. |
| 6 | Grading roof for water proofing treatment with water proffing compound.Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. |
| 8 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 9 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 10 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110 mm dia |
| 11 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87 .5 -110mm dia |
| 12 | Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS:8183, having density 48 kg/m3, 50 mm thick, fixed on the roof top with screws, rawel plug & washers and held and in position by criss crossing GI wire etc. complete as per directions of Engineer-in-charge. |
| 13 | ELETRIC WORK |
| 14 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. asrequired. |
| 15 | Short point (up to 3 mtr.) |
| 16 | Medium point (up to 6 mtr.) |
| 17 | Long point (up to 10 mtr.) |
| 18 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit &it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testingetc. as required. |
| 19 | On board |
| 20 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVCconduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good thesame as required. |
| 21 | 25 mm |
| 22 | 32 mm |
| 23 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size,Ferrules,testing etc. as required. |
| 24 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 25 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 26 | 4 x 10.0 sq.mm |
| 27 | 4 x 6.0 sq.mm |
| 28 | 1 x 4.0 sq.mm |
| 29 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 608981 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 Arating, 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. |
| 30 | Single pole MCB (With B / C curvetripping characteristics) |
| 31 | 6 A to 32 A rating |
| 32 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 25sq.mm. IP20 contact protection and fitted in existing distribution board / sheet including making connections, testingetc. as required. |
| 33 | Four pole Isolator |
| 34 | 80 A/100 A rating |
| 35 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. asrequired. |
| 36 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to125 A Rating with Metal end box |
| 37 | 4 Way |
| 38 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS:3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including makingconnections, testing etc as required. |
| 39 | 32 Amp. 2 Module switch With LedIndicator |
| 40 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 41 | 6/16 A shuttered socket |
| 42 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 43 | 8 Module |
| 44 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories asrequired. |
| 45 | 6-8 Module |
| 46 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. |
| 47 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver, System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 ,life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K/ 4000°K / 5700°K /6000°K/6500°K(As per ANSI Bin) as required. |
| 48 | 1170mm(+/-10%) LED batten withmin. lumen output 2200 lm |
| 49 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 50 | Recessed Mounting |
| 51 | Minimum lumen output 4320 lm |
| 52 | SITC of 3 /4 pole current limitingMoulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock& rotary handle ( to be paid extra) , |
| 53 | 4 pole MCCB With Thermal Magnetic release |
| 54 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 55 | Providing & Laying XLPE insulated &P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as requiredof following size. |
| 56 | 10.0 Sq. mm |
| 57 | 2 core |
| 58 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. |
| 59 | Suitable for Two / Three / Four module for MCB Please Enable Macros to View BoQ information |