Tender For Maintenance Of Various E&M Services At Thyagraj Sports Complex, New Delhi. (Sh: Supplying, Installation, Testing And Commissioning Of Dewatering System Automation And Management System With Microprocessor Based Control Panel, Online Monito, Delhi-Delhi
TDR : 54545790
Tender Notice
BOQ
5 Days Left
Delhi
Delhi
Tender For Maintenance Of Various E&M Services At Thyagraj Sports Complex, New Delhi. (Sh: Supplying, Installation, Testing And Commissioning Of Dewatering System Automation And Management System With Microprocessor Based Control Panel, Online Monito
Name of Work:- Maintenance of Various E&M Services at Thyagraj Sports Complex, New Delhi. (SH: Supplying, Installation, Testing and commissioning of Dewatering System automation and management system with microprocessor based control panel, online monitoring and wireless connectivity with SCADA Software at Basement of Thyagraj Stadium).
1.13) MMU (Master Microprocessor Unit) With Smart Graphical Display Size 7\\" Inbuilt Software Application with wireless connectivity for all wireless device communication & cloud communication with wireless connectivity, Current transformer to be installed in pump house with following accessories listed below: Micro Processor Unit shall have control, protection & live data devices up to 6 Pumps 10 Sensor Micro Processor Fast Fourier transformation to eliminate harmonics &, Surges True RMS measurements & simultaneous sampling of Volts, Amps 2 layer protection & each 1/0 controller protected with a single form factor for multiple technologies high performance & accuracy with real time clock wireless connectivity compatible,data backup, various functions high Speed mode with instant switches from one input to the other & can be controlled in slot for memory with conncoted to external devices like android/os/windows platform & Pe through software key - CGPS plug - in software. Software key should comprised of UDP/ FTP/HTTP open standard Internal Expansion Wireless CPUR: with an core ARM7 32- bit foating point (72 MIZ max) microprocessor, with integrated IDE & GPRS connection with Uptime - Minimum 95%, Download Speed up to -4 Mbps Transter unlimited of all measured parameters/ quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. - 1 No.
3
Supplying installation testing & commissioning of Ultrasonic Sensor status of water tank output analog approx. liquid Quantity in tank, made of ABS housing, detection range not less than 2 meters, output analog approx, liquid quantity in Tank, etc. complete as required.
4
Supplying, installation, testing & commissioning of microprocessor, suitable with control & wireless connectivity device transmitter and receiver (To be installed nearby sensor & line pressure transmitters for wireless data Range upto 1000 meters i/c sending data from upward to downward) for sending status of water tank to Master Microprocessor unit of on real time basis, for sending/receiving data from SCADA. Made of ABS Housing, Control :- Relay Based output & Display at 50 Level Water in tank indicator with suitable control panel operated at SPMCB 6 AMP. 230V single phase 50 Hz AC supply etc. complete as required.
5
Supplying, installation, testing and commissioning of One CPU One LED 55\\" Display with Complete SCADA (Supervisory Control & Data Acquisition Software System) With wireless connectivity for AUTOMATIZATION of Pump house , water tank level for on line Monitoring pump house , Over Head Tanks & Under Ground Tanks with following specification. Server application for monitoring and controlling of system Data receive and sent through central application, event log store in server and can be checked, different level Message to different installation uit and location Software can be breakup in to different level for checking whole pump house and Tank Levels according to the client needs. Data Recipient should be added or delete manually according to the need as per the office requirement .Online Monitoring application should be within System for tracking. Data storage should be at central server for proper backup and support. Gateway server will manage all the incoming and outgoing Data. Fault or any breakdown reported immediately to concerned person through mobile messaging (persons can be 2 number). Each operations log stored in server & can be checked later on. Software can be breakup in to different level for checking whole pump house according to the client needs. Report can be checked according to the predefined level. Pump House data of different units can be stored in the software and Data will be done according to the employees in the unit. On network failure message should resend the data again. Internet tracking of all the operation in pump house through Web Login .
6
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power Copper armoured cable of 1.1 KV grade of following size on wall surface as required. (a) 8 x 1.5 Sq.mm
7
SITC of 1 KVA UPS single phase 3 pin output socket including connection etc. as required (Make Microtek) Please Enable Macros to View BoQ information