Name of Work:- Providing Stabilizer / VFD starter at Rajur Tal - Akole Dist-Ahilyanagar
Sl. No.
Item Description
1
Rewinding of motorProviding, erecting and giving test and trial of Heavy Duty Variable Frequency Drive with Speed and Torque Control, Built-in by pass contactor and all Motor Protections and external Semi-conductor fuses, Display and keypad, bus bars etc complete assembled in an SWG 14 IP23 and above Enclosure. CE Certified and Complient to EN 61800-5-1:2007Application:- General Purpose Water PumpingOperational Voltage 380-600VACControl Voltage 110-250VACHarmonics Compliance: Built-in optimized dual DC choke / AC Choke as standard in AC560-01 (R3-R9) meets the requirements of IEC 61000-3-12:2011.Temp Range: -40 to 70 Deg C, 5% to 95% RH, Air Cooled with third party inspection and as per detailed specification.For 100 HP
2
VFD StarterProviding, erecting and giving test and trial of Heavy Duty Variable Frequency Drive with Speed and Torque Contro, Built-in by pass contactor and all Motor Protections and external Semi-conductor fuses, Display and keypad,bus bars etc complete assembled in an SWG 14 IP23 and above Enclosure. CE Certified and Complient toEN 61800-5-1:2007Application:- General Purpose Water PumpingOperational Voltage 380-600VACControl Voltage 110-250VACHarmonics Compliance: Built-in optimized dual DC choke / AC Choke as standard in AC560-01 (R3-R9) meets the requirements of IEC 61000-3-12:2011.Temp Range -40 to 70 Deg C, 5% to 95% RH, Air Cooled with third party Inspection and as per detailed spacification.
3
Voltage StabilizerProviding, erecting Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415Volt+/-1%, 3Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed incubical box, with bi-directional wheels for easy handling, necessary monitors and user's controls on front and user's controls on front panel suchas indication, alarm,voltmeter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/ Low push buttons etc. Suitable capacity termination strips and busbars for incoming and outgoing cable should be provided. All three phases shall be independently monitored and corrected. Following protections and Indications shall be incorporated Over Voltage / Under Voltage Single Phasing Cutoff contactor with electronic output sensing unit.
4
CableProviding, erecting.terminating XLPE/PVC insulated armoured aluminium conductor Of following sizes 1100 V grade cable as per detailed specification attached.Supplying, erecting & terminating XLPE armoured cable 3% core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per spec Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.