| 1 | PART-A 11KV LINE LENGTH WITH 50 MTR SPAN Top Channel Arm 100 x 50 x 6 mm (9.56 Kg/ mtr) Each channel length 1.2 mtr, 2 No's channel required=(2x9.56x1.2) |
| 2 | Fish plate 50x6 mm., 2.36kg/mtr., each 0.280 mtr. Length, 8no's required(8x2.36x0.28) |
| 3 | Straighy Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 0.306 mtr,4 no's channel required |
| 4 | 11 KV pin insulator polymer |
| 5 | H W fitting (B&S) 70 KN, 3 Bolt |
| 6 | Disc insulator (B&S) 70 KN polymer |
| 7 | PG clamp for 55 sq mm AAA conductor |
| 8 | GI Nut, Bolt & Washer of Different Sizes (7.433 Kg each cut pole) |
| 9 | MATERIALS FOR 11KV PIN POINT WITH WPBWPB 160x152 (11 Mtr Long, 30.44 KG/Mtr) |
| 10 | Top Channel Arm 100 x 50 x 6 mm (9.56 Kg/ mtr) Each channel length 1.2 mtr, 2 No's channel required=(2x9.56x1.2) |
| 11 | Fish plate 50x6 mm., 2.36kg/mtr., each 0.280 mtr. Length, 8no's required(8x2.36x0.28) |
| 12 | Straighy Cross Arm 100x50x6 mm, 9.56 Kg/mtr each Channel Length 0.306 mtr,4 no's channel required |
| 13 | Danger Plate 2 No's |
| 14 | Back Clamp for danger plate 25x3 mm. flat, 0.59 Kg/Mtr.flat of 0.510mt length 1 no's=(1x0.59x0.510) |
| 15 | GI barbed wire anticlimbing devices 3Kg. Per support, 2 no's quantity |
| 16 | Back Clamp for anticlimbing device 25x3 mm., flat, 0.51 Kg/Mtr.(4x0.59x0.51) |
| 17 | 11 KV pin insulator polymer |
| 18 | H W fitting (B&S) 70 KN, 3 Bolt |
| 19 | Disc insulator (B&S) 70 KN polymer |
| 20 | Earthing of support coil type |
| 21 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/mtr-2 mtr. For Connecting pole with coil Earthing |
| 22 | PG clamp for 55 sq mm AAA conductor |
| 23 | HT Stay clamp,50x8mm flat,3.14kg/mtr, 0.551 mt length 2 nos quantity required (1 pair) |
| 24 | HT stay set complete |
| 25 | HT stay insulator TYPE-C |
| 26 | 7/10 SWG GI stay wire Grade-2 (15 Kg/set) |
| 27 | GI Nut, Bolt & Washer of Different Sizes (7.433 Kg each cut pole) |
| 28 | Black paint |
| 29 | Yellow colour paint for background |
| 30 | Civil & Services Fixing of Complete 11KV line Complete stay set included 1) turn buckle Assembly 2) Stay rod & Stay Plate 3) stay Insulator 4)stay wire 5)Stay clamps with nuts & bolts BA will do the excavation including excavation,supply of 0.5 cum cement concrete foundat |
| 31 | Concreting ratio 1:1.5:3 (500mmx500mmx1800mm)= 0.45 cu mtr |
| 32 | Coupling ratio 1:1.5:3 (500x500x450 mm) =0.1125 cu mtr. |
| 33 | MATERIALS FOR 11KV PIN POINT WITH WPBWPB 160 X152 (11 mtr. Long 30.44 KG/ MTR) |
| 34 | 11KV V Cross Arm (10.2 Kg each) |
| 35 | Top Bracket100x50x6 mm GI Channel |
| 36 | Danger Plate 1 No's |
| 37 | Back Clamp for danger plate 25x3 mm. flat, 0.59 Kg/Mtr.flat of 0.510mt length 4 no's=(1x0.59x0.510) |
| 38 | GI barbed wire/ Anticlinbing device (3kg/pole) |
| 39 | Back Clamp for anticlimbing device 25x3 mm., flat, 0.59 Kg/Mtr.(4x0.59x0.51) |
| 40 | 11 KV pin insulator polymer |
| 41 | Earthing of support coil type |
| 42 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/mtr-2 mtr. For Connecting pole with coil Earthing |
| 43 | GI nuts & bolts of Assorted size (1.45 kg /pin point) |
| 44 | 55 mm2 AAAC |
| 45 | Black Paint |
| 46 | Yellow' Colour Paint for Background |
| 47 | Civil & Services Concreting ratio 1:1.5:3 (500mmx500mmx1800mm)= 0.45 cu mtr |
| 48 | Coupling ratio 1:1.5:3 (500x500x450 mm) =0.1125 cu mtr. |
| 49 | PART-B 25KVA Plinth Mounted DTR WPB 160X152 (11Mtr Long, 30.44KG/Mtr.) |
| 50 | Top Channel Arm 100 x 50 x 6 mm (9.56 Kg/ mtr) Each channel length 1.2 mtr, 2 No's channel required=(2x9.56x1.2) |
| 51 | Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280) |
| 52 | AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg/Mtr., 2 No's.) (Each 2x3.000x7.14)= 42.84 Kg) |
| 53 | AB Switch Side Support Channel l00X50X6mm,9.56 KG/Mtr, each channel length 0.35 mtr., 2 no’s channel required ( 9.56X2 x0.35) |
| 54 | Channel Support for down Pipe 75X40X 4.8 mm 7.14KG/ Mtr each channel length 0.8 Mtr., 1 no's channel required = (7.14x0.8x1) |
| 55 | HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000X7.1 4= 42.84 Kg) |
| 56 | Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7 .14Kg. /Mtr., 2 No's.) (Each 2X0.810x7.14)= 11.57 Kg) |
| 57 | Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No'S.) (Each 2x1.282x4.5 = 11 .54Kg) |
| 58 | Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long ) Kg (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg) |
| 59 | Transfomer Base Support Gl Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2X0.5 15x9.56= 9.85Kg) |
| 60 | Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4,5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg) |
| 61 | Transfomer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4 .5Kg./Mtr,2 No's) (Each 2X0.580x4.5= Kg) |
| 62 | LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4. 5Kg.fMtr, 2 No's) (Each 2x1x4.5 Kg) |
| 63 | 50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 Mtr. For mesh formation,12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr for DTH Body,0.5mt for LTDB & AB Switch operating handle, 3 mtr for fencing) (each 65.6x2.36=154.81 kg) |
| 64 | 25 KVA , 11/ 0.4 KV (AL) Transformer BlS Energy level II |
| 65 | LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S |
| 66 | 55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.) |
| 67 | 4 Cx 35 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf. |
| 68 | AB Switch(11 KV,200A.3pole,50Hz) |
| 69 | H.G.Fuse( 11KV.200A.3Pole) |
| 70 | PG Clamp for 55 sq.mm AAA conductor |
| 71 | Disc insulator (B& S)70 KN polymer |
| 72 | H W fitting (B&S)70KN(3bolted) |
| 73 | Lightning Arrester(l2KV, 10KA) Station Class 2 |
| 74 | l l KV pin insulator polymer |
| 75 | HT Stay set complete |
| 76 | HT stay clamp (1.9 Kg/ pair) |
| 77 | HT stay insulator TYPE-C |
| 78 | 7/10 SWG GI stay wire Grade-2 (15 Kg/set) |
| 79 | 40 mm nominal bore G.I pipe (medium gauge) earling device with 3 mtr long) |
| 80 | GI nuts & bolts of Assorted size (25 kg /DSS DP) |
| 81 | GI barbed wire / Anticlimbing size (3 kg /DP) |
| 82 | Black Clamp for Anticlimbing device 25x3 mm,flat of 0.510 mt length 8 nos=(8x0.59x0.51) |
| 83 | Danger plate 11 kv |
| 84 | Black Clamp for Anticlimbing device 25x3 mm, flat of 0.510m length 2 nos=(2x0.59x0.510) |
| 85 | Name plate |
| 86 | Structure Numbering and MarkingYellow' Colour Paint for Background |
| 87 | Block Colour Pnint for numbering |
| 88 | Civil & Services workConcreting ratio 1: 1: 5: 3(500 mm X500 mmX 1800mm) = 0.450 Cu. Mtr |
| 89 | Couping ratio 1: l.3:3 (500 mm X500 mmX450 mm) = 0.1113 cu. Mtr |
| 90 | Fixing of stay set with 0.5Cum cement concrete foundation l:3:6 size( 900mmx600mmx900mm) using 40mm BHG metal with all labour and material except stay set, stay wire , stay insulator . |
| 91 | Construction of earthing chamber including installation of earthing pipe making earthing chamber including excavation,soil treatment with bentonide powder, calculation of earth resistance , including installation of 3mt GI pipe 40mm/50mm including welding of GI flat around pipe |
| 92 | Supply and Erection of GI Fencing with Gate |
| 93 | MATERIALS FOR SERVICE CONNECTION4c X 10 SQ MM Armoured aluminium cable - XLPE insulated |
| 94 | Insulated piercing connector Type- C main 16 to 95 sq mm & Tap 1.5 to 16 sq mm For LT AB Cable |
| 95 | GI Nut, Bolt & washer Please Enable Macros to View BoQ information |