| 1 | Supply and erection of Generator at Mantharanputhoor Water Source at Mantharanputhoor Pumping station in Kanniyakumari Municipality |
| 2 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum( DATA) |
| 3 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 4 | Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 5 | Plain Cement Concrete 1:5:10 (one cement five fine aggregates and ten coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 7 | Vibrated Cement Concrete M20 (Design mix) using 20 mm ISS HBG graded metal including cost and conveyance of all materials to site and cement at site excluding cost and fabrication of steel but form work and centering soft water labour charges for mixing, transporting, placing in position, vibrating and compacting finishing and curing concrete, working at heights, hire charges for Hire charges for Tools and plants, including all other incidental charges, etc., complete as per standard specifications |
| 8 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 9 | Supply and delivery of 58.50KVA water cooled Diesel Genset with sound prosing and reputed company ISI/ISO specification..ENGINE: 1 a) Generator oil engine Lit, 58.50 KVA 3 Phase WATER cooled diesel engine developing Suitable 608 HP at 1500 rpm Voltage 415/215 in of 0.80 PF incorporating the following accessories.Supply and delivery of 58.50 KVA water cooled Diesel Genset with sound prosing and reputed company ISI/ISO specification..ENGINE: 1 a) Generator oil engine Lit, 58.50KVA 3 Phase WATER cooled diesel engine developing Suitable 156 HP at 1500 rpm Voltage 415/215 in of 0.80 PF incorporating the following accessories.ALTERNATOR:1 Brushless type alternator rated suitable for 58.50KVA @1500rpm 415 volts, 0.80 P.F. 50Hz, 3 phase, 4 wire self regulated as per manufacturer standardCONTROL PANEL: 1 Fabricated sheet steel construction, floor mounting indoor type, dust and vermin proof, inner-hinged panel with un-drilled removable bottom plate incorporating the following control main and control unit as per manufacturer standard. The Control panel should be mounted outside the genset canopyBEST QUALITY Canopy (Sound Proof Acoustic Enclosure) Suitable for 58.50 KVA DG set. and inbuilt Auto Start Stop Panel.Exclusion: Exhaust piping outside the canopy DG Set dimension. (Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BISSpecifications With AMF Panel PWD SOR 2025-26 Pg 268 (M-2331) |
| 10 | 3 core 16sq.mm PVC copper UG cable M-2581 |
| 11 | Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD Earthing SD 659 |
| 12 | Supply and fixing of Cable gland suitable for 4 core 25sq. Mm UG Cable M-1593 |
| 13 | Supply and fixing Neutral link 15Amps of M-1597 |
| 14 | 4 core 16 sq.mm. PVC Armoured UG Cable M-1562 |
| 15 | Supply and fixing Hard drawn copper conductor (Gaugeno. 8&6) M-1571 |
| 16 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \\"BB\\" for all works in this package} Please Enable Macros to View BoQ information |