| 1 | WORK NAME |
| 2 | Part - B (Non BSR)Annual Maintenance, Service of water cooler including all accessories required for running condition ,with water cooler compressor Replacement , with gas filling, power cable board pipe ,including aquaguard & R.O. COMPLETE IN ALL RESPECT For running condition .(Fix charge for AMC) for 24 months. |
| 3 | Annual maintenance contract (A.M.C.) for regular operation & maintenance of A.C. unit (Air Conditioner) at nagar nigam Administration building with material as required for running condition etc. complete in all respect.(i) 18 H.P. ODU (18 nos X 2 years) |
| 4 | (ii) 16 H.P. ODU (16 nos X 2 years) |
| 5 | shifting of AC one palace to another palace providing & fixing complete including connection, transportation in all respect. |
| 6 | S/F AC , Refrigerant copper pipe 14/ LG |
| 7 | S/F iron stand 17 / LG for all type split Air conditioner |
| 8 | S/F Drainage pipe 15/LG |
| 9 | S/F AC valve complete set ¼ ” x ¼ ” and ½ ” x ½ ” |
| 10 | S/F PCB electric circuit for AC complete set |
| 11 | P&F Refrigerator- 5 Star Rating 190 ltr. Single Door etc. with making Connection etc. complete LG-Voltas |
| 12 | WORK NAME |
| 13 | PART - A (RUIDP ISOR 2023)Replacement of defective compressor by company repairedcompressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 1.5 TR A.C. |
| 14 | 2.0 TR A.C. |
| 15 | 150/150 Ltr. Water cooler |
| 16 | Supplying and charging of fresh refrigerant and testing ofperformance of air conditioner/ fridge/ water cooler of following capacity including capillary 2.0 TR Window/ Split A.C. |
| 17 | 150/150 Ltr. Water cooler |
| 18 | P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. v1.5 TR A.C. |
| 19 | 2.0 TR A.C. |
| 20 | 150/150 Ltr. Water cooler |
| 21 | Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner |
| 22 | P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 23 | P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 24 | P & Replacement of starting relay of A.C/water cooler/fridgecompressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 25 | S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.Starting capacitor 40-60 micro farad |
| 26 | Running capacitor 25.0 micro farad |
| 27 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter-56 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 28 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR6.0 sq.mm |
| 29 | 10.0 sq.mm |
| 30 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank . |
| 31 | Providing and fixing Polyethylene-Aluminium- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80 C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required ) e.g. elbows ,tees ,reducers,couplers & connectors etc. with clamps at 1.00 metre spacing. this includes testing of joints complete as per direction of the Engineer in-charge.1620 (20 mm OD) pipe |
| 32 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 33 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 34 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 35 | G.I. tees (equal) 25 mm |
| 36 | G.I. elbows 20 mm dia |
| 37 | G.I. Union 20 mm nominal bore |
| 38 | Supply of P.V.C. hose pipe 38 m dia at site/ store i/c all complete |
| 39 | Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more required complete with frame work with 50 X 50 X 6mm angle ironpost 30 cm in ground embeded in cement concrete 1:3:6(30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of size complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |