| 1 | Construction of embankment with approved material obtained from availble land as permitted and approved by Engineer-in-Charge and as per Technical Specitaion Clause 301.3.4.1, with all lifts and leads, spreading, grading to required slope and compacting to meet requirement of Tables 300.1and 300.2 as per Technical Specification clause 301.5 (Excluding G.S.T.) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soll and disposal of surplus excavated soll as directed, within a lead of 50 m.including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the all kind of soil as per S.I. No. 2.8.1 (Excluding G.S.T.) |
| 3 | Providing, laying and spreading material on a prepared subgrade, adding cement @ 2% by weight to the spread material manually, mixing in place with Rotavator and compacting with the Road Roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base. (Excluding G.S.T.) |
| 4 | Providing ,Laying ,spreading Material on a prepared sub base,cement@4% by weight to the spread material manually mixing in place with rotavator and compacting with the road roller at OMC to achieve the desired unconfied compressive strength and to form a layer of base. (Excluding G.S.T.) |
| 5 | Providing and applying tack coat with VG_10 using bitumen distributor at the rate of 0.3 kg per sqm on the prepared surface cleaned hydraulic broom. (Excluding G.S.T.) |
| 6 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen (80/100) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a HMP plant, laying with Paver and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type C as per Technical Specification Clause 508. (Excluding G.S.T.) |
| 7 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using bitumen (80/100) for Type C as per Technical Specification Clause 510. (Excluding G.S.T.) |
| 8 | Plain cement concrement 1:3:6 nominal mix in foundation with crushed aggregate 40 mm nominal size mechanically mixed,placed in foundation and compected by vibration including curing for 14 days. (Excluding G.S.T.) |
| 9 | Brick masonry work in 1:3 cement mortar in foundation complete excluding pointing and plastering as per drawing and technical speficiations clauses 600, 1202 & 1203. (Excluding G.S.T.) |
| 10 | Providing and laying reinforced cement concrete M 20 grade in superstructure as per drawing and technical specifications clauses 800, 1205.4 and 1205.5. (Excluding G.S.T.) |
| 11 | Supplying fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and Technical Specifications clauses 1002, 1010 and 1202. (Excluding G.S.T.) |
| 12 | Pointing with cement mortar (1:3) on brickwork in sub structure & super structure as per drawing and technical specification clauses 613.3 , 1204 and 1208.4. (Excluding G.S.T.) |
| 13 | Plastering with cement mortar (1:4) 12 mm thick on brickwork in substructure/superstracutre as per technical specification clauses 613.4 & 1204. (Excluding G.S.T.) |
| 14 | Laying reinforced cement concrement pipe for culverts on first class bedding of granular material in single row including fixing collar with cement motar 1:2 but excluding excavation,protection works,back filling,concrete and masonary works in head walls and parapets350 mm dia. (Excluding G.S.T.) |
| 15 | Laying reinforced cement concrement pipe 600mm Dia for culverts on first class bedding of granular material in single row including fixing collar with cement motar 1:2 but excluding excavation,protection works,back filling,concrete and masonary works in head walls and parapets (Excluding G.S.T.) |
| 16 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. (Excluding GST) |
| 17 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. (Excluding GST) |
| 18 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawing. (90 cm equiltateral with diffinitation plate size (20cm x 60)cm (Excluding GST) Please Enable Macros to View BoQ information |