| 1 | Electrification |
| 2 | 90.15.2.2:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters |
| 3 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 4 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 5 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 6 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 7 | OD367697/2025-2026:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in positionand binding all complete |
| 8 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 9 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 10 | 90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm |
| 11 | OD367707/2025-2026:Supply Conveyance, installation, testing and commissioning of g 25A, 2Pole, AC 1 ratedpower contactor with 1NO+1NC auxiliary contacts & with AC coil |
| 12 | OD367702/2025-2026:Supply Conveyance, installation, testing and commissioning of 24 Hours Analog Timer foroperating automatic ON-OFF function |
| 13 | OD367699/2025-2026:Supply and Fixing of 1P+N,40KA,1 module surge protector on existing MCB DB/enclosure/Meter Board etc and giving connection as required. (Schneider A9L40500 or equivalent). |
| 14 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 15 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 16 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 17 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 18 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 19 | 90.1.1.2:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm |
| 20 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 21 | OD367698/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections,in existing meter board |
| 22 | OD367700/2025-2026:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meterboard |
| 23 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 24 | OD367706/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc |
| 25 | OD367703/2025-2026:Supply and installation of dust and vermin proof sintex box (GS-MB-4030) and to fix MCB and isolator etc. as required , including fixing it on existing concrete pillar. Giving connection as required. |
| 26 | OD367704/2025-2026:Supply and installation of dust and vermin proof sintex box (3425) and to fix MCB and isolator etc. as required , including fixing it on existing concrete pillar. Giving connection as required. |
| 27 | OD367695/2025-2026:Supply,Conveyance and fixing the following size of GI pipe along with painting 2 coats of synthetic enamel paint over a coat of synthetic enamal paint over a coat of zinc chromate primer etc as required 40 mm dia GI pipe (medium class ) |
| 28 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 29 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 30 | OD367701/2025-2026:Supply , laying and joining of 32 mm or nearest size green flexible PVC Pipe for SubmersiblePumps Approved make specials as delivery pipe using required leak proofing materials etc. asrequired |
| 31 | OD370124/2025-2026:Providing and fixing Granite Board of 500 mm X 400 mm, with inscription on front side asrequired as per the instruction |
| 32 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 33 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 34 | OD367696/2025-2026:Charges for preparation of KSEB test Report for submitting to the concerned KSEB section office Please Enable Macros to View BoQ information |