| 1 | Electrification |
| 2 | OD247043/2025-2026:Supply, Installation and commissioning of 2 KVA/24VDC Pure sine wave DSP controlled Home UPS the following specification. Capacity 2 KVA, UPS, Nominal input voltage 230+/-25% VAC, Single Phase Input Single Phase output, Nominal Input frequency 50 HZ +/_ 5%Hz, Nominal output voltage 230 V AC Single phase, Output voltage regulation +/-1%, Nominal output frequency 50 Hz, Output frequency tolerance +/-1%, Ventilation Forced Air cooled, LED/LCD Display for Mains on, Inverter on, Battery Low, Over Load, Trip, Load Percentage, Common Alarm Battery low, Over load with 2 nos of 12V/150Ah Tubular Battery with Rack for battery/UPS and accessories. 3Year onsite warranty for UPS and Battery (make UPS Hykon, Luminous, Zenrise, Zenster and Battery Hykon, Luminous, Exide ) |
| 3 | 90.10.1.4:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface |
| 4 | 1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 5 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 6 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 7 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 8 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 9 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 10 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm Please Enable Macros to View BoQ information |